PaGE 18
KrP PrEP taBlEs
8D - clEanInG: conDEnsInG unIt
(contInuED)
:
The filter is located behind the louvered panel, below the condensing unit in the
compressor compartment. Remove filter by carefully sliding out of the tracks. Carefully
clean with vacuum or rinse with hot water exercising care not to bend or damage filter
frame. Replace filter by carefully sliding it into the tracks. Replace louvered panel by
installing top of panel into track and pushing in the bottom so that the locking clips fit
inside the opening. Replace rear access panel. Reconnect electrical supply.
Models 27 through 36: The condensing unit is located in the back of the unit, behind
the removable, slotted access panel. The condensing unit coil must be cleaned regularly.
Remove the access panel using a phillips head screwdriver. Carefully clean dirt and lint
from the condenser coil using a vacuum cleaner or soft brush; do not use a wire brush.
These units do not have a removable filter. Replace slotted access panel. Reconnect
electrical supply.
Replacement filters are available through Kairak Parts and Service Department at
800-
833-1106.
8E - clEanInG: EVaPorator coIls:
WarnInG: DIsconnEct ElEctrIcal PoWEr suPPlY BEForE clEanInG anY
Parts on tHE unIt.
Evaporator coils should be cleaned every six (6) months for optimal performance.
The evaporator coils are located in the storage cabinet behind the coil can cover. With a
phillips head screwdriver, remove four screws and take off cover. Clean evaporator coils
with a vacuum cleaner or soft brush, do not use a wire brush. Replace coil can cover.
Reconnect electrical supply.
8. MaIntEnancE ProcEDurEs
(cont.)