PaGE 19
KrP PrEP taBlEs
9. trouBlEsHootInG
ProBlEM
PossIBlE causE
1.
Compressor fails to operate
• Power failure.
• Plug loose in receptacle or unplugged.
• Blown fuse or tripped circuit breaker.
• Main power switch is Off.
• Temperature controls or time clock not set properly.
2. Condensing unit operates for pro-
longed periods or continuously.
• Door gaskets not sealing properly.
• Condensing unit filter is dirty.
• Evaporator coil is iced up or dirty.
• Prolonged and/or frequent door openings or door(s)
ajar.
• Excessive load of warm food placed into lower storage
cabinet.
3.
Lower storage cabinet not holding
temperature.
• Temperature control and/or time clock not set properly.
• Door gaskets not sealing properly.
• Inadequate air circulation due to product loading.
• Evaporator coil is iced up or dirty.
4.
Pan Chiller not holding temperature. • Temperature control and/or time clock not set properly.
• Cooling fans not operating
• Evaporator coil is iced up or dirty.
sErVIcE
For additional information, contact Kairak Parts and Service Department:
800-833-1106.