Kairak’s  warranty  coverage  warrants  that  Kairak-branded  products  are  free  of  defects  in  materials  and  factory 
workmanship. The following applies to all Kairak Model and Serial numbers.  

Kairak’s warranty is extended only to the original purchaser and shall not apply to any failures resulting from damage 
in transit, improper installation, alteration, normal wear, misuse, abuse, improper voltage, accident or negligence. The 
warranty excludes; T-stat adjustments, time clock adjustments, gaskets, cutting boards, filters, clogged drains, ice 
build-up with no mechanical failures, and the loss of contamination of food due to mechanical or electrical failure. 
Warranty does not apply outside the United States.

In order to be covered under this warranty, prior authorization to perform the necessary and appropriate service must 
be obtained from the factory. Model and Serial number must be provided at the time of service request. Kairak does not 
assume responsibility for any expenses, including labor, parts or travel expenses incurred without such prior authorization. 
Kairak shall not be liable, whether in contract or in tort or under any other legal theory for loss of use, revenue or profit, 
substitute use or performance, incidental, indirect or special and/or consequential damages, loss of refrigerant or for 
any other loss or cost of similar type.  Such related charges will be back charged to the responsible party. The decision 
of the Kairak Service and Warranty, as to whether a defect is within the terms of this warranty shall be final.

Failure to object or provision contained in a customer’s purchase order or other communication shall not be deemed 
as a waiver of terms or conditions of their warranty, nor shall it be considered acceptance of such provisions. This 
warranty supersedes and is in lieu of all other warranties, expressed or implied and of other obligations of liabilities, 
on the part of Kairak.

In case of freight damage, do not refuse shipment, but call agent’s attention to its condition, making careful note of the 
details on freight bill before freight charges are paid. File claim for damages with freight agent immediately. 

Blu FIXturEs manufactured by Kairak hold a 3-year parts and labor warranty. Kairak holds a 5-year compressor 
warranty, with a one-time compressor only replacement after the first year.  Kairak will warranty the labor to replace 
the compressor for the first three years, 30 days from the ship date. After the first three years, labor, tax, shipping 
and miscellaneous parts will not be included. Please contact our warranty department for compressor replacement 
procedures during the warranty period. BLU remote Fixtures are designed to operate with Kairak remote systems only. 
Violation of these terms will void all warranty.

rEFrIGErant FIXturEs manufactured by Kairak hold a 1-year parts and labor warranty.  Kairak holds a 5-year 
compressor  warranty,  with  a  one-time  compressor  only  replacement  after  the  first  year.    Kairak  will  warranty  the 
labor to replace the compressor for the first year, 30 days from the ship date. After the first year, labor, tax, shipping 
and miscellaneous parts will not be included. Please contact our warranty department for compressor replacement 
procedures during the warranty period.  

rEMotE sYstEMs manufactured by Kairak hold a 1-year parts and 90-day labor warranty on the remote system, 
with an option to purchase 1-year labor warranty at the time of purchase order receipt. This warranty does not apply 
to  motors,  switches,  controls,  accessories  or  parts  manufactured  by  others  and  purchased  by  Kairak,  unless  the 
manufacturer warranties the same to Kairak. Kairak holds a 5-year compressor warranty, with a one-time compressor 
only replacement after the first year.  Kairak will warranty the labor to replace the compressor for the first year, 30 days 
from the ship date. After the first year, labor, tax, shipping and miscellaneous parts will not be included. Please contact 
our warranty department for compressor replacement procedures during the warranty period.  

to rEQuEst autHorIzED sErVIcE, call tHE KaIraK sErVIcE anD WarrantY HotlInE: (800) 833-1106. 
After-hour requests must be urgent in nature and documented with Kairak’s after-hours service line prior to service being 
performed. Kairak is responsible for straight time only, unless otherwise approved by the warranty department.

11. WarrantIEs

Summary of Contents for KRP

Page 1: ...Instruction Manual KRP PREP TABLES 500 S State College Blvd Fullerton CA 92831 Phone 714 870 8661 Fax 714 870 6473 www kairak com KAIRAK a division of ITW Food Equipment Group LLC All Rights Reserved...

Page 2: ...n Chillers B Removing Food Product At Night C Leaving Food Product In Overnight D Defrost Time Clock Settings Freezer Models E Temperature Control Settings 7 OPERATION a Pan Chiller B Lower Storage Ca...

Page 3: ...AL MODEL VOLTS Hz PH TOTAL CURRENT AMPS MINIMUM CIRCUIT AMPS MAXIMUM OVERCURRENT PROTECTION AMPS LIGHTS WATTS HEATERS AMPS REFRIGERANT TYPE OZ DESIGN PRESSURE HIGH LOW REFRIGERANT TYPE OZ DESIGN PRESS...

Page 4: ...contact Kairak customer care at 714 870 8661 to request a return 3 installation 3A UNPACKING Inspect equipment for shipping damage prior to installation If shipping damage is found save the packing m...

Page 5: ...UNTER 3D INSTALLING PARTS SHIPPED LOOSE COMPRESSOR FILTER Remove louvered panel by lifting up and pulling out entire panel Slide the filter into the tracks located below the compressor compartment Be...

Page 6: ...To install attach the two 2 mounting rails to the bottom of the cabinet with 4 or 6 depending on the model 6 32 x 3 8 phillips head screws Place the condensate evaporator in the heater bracket Slide t...

Page 7: ...erant line brazing 50 50 or cold solder is not acceptable For system charge follow remote refrigeration system manufacturer s instructions 5 ELECTRICAL CONNECTIONS Refer to the wiring diagram shipped...

Page 8: ...se note that the clock face is divided into 24 hours See Fig 5 On self contained units the time clock is located inside the compressor compartment Remove louvered panel by lifting up and pulling out e...

Page 9: ...ng the food product in the pan chiller overnight defrost time clock needs to be set to cycle off and on throughout the night Time clock must be set to run for 15 minutes on and 60 minutes off consiste...

Page 10: ...eriod The factory defrost setting is off at 12 00 a m 8 00 a m and 4 00 p m for 15 minutes each To change this setting set the pins to desired off times Each pin represents 15 minutes Pins pulled out...

Page 11: ...k of the machine See Fig 8 DEFROST TIME CLOCK PAN CHILLER TEMPERATURE CONTROL FIG 8 FIG 9 DEFROST TIME CLOCK POWER SWITCH PAN CHILLER TEMPERATURE CONTROL REFRIGERATED BASE TEMPERATURE CONTROL On self...

Page 12: ...arked Pan Chiller should be set at 23 F with a 3 F differential The operating display range should read between 20 F and 28 F Temperature control marked Base Refrigerator should be set at 37 F with a...

Page 13: ...pans will help prevent over chilling 7 For remote refrigerators with pan chiller systems it is imperative that the existing refrigeration equipment must be sized properly and in good working conditio...

Page 14: ...loth Always rub in the same direction as the grain pattern on the stainless steel To clean the inside of the lower storage cabinet remove wire shelves All wire shelves are adjustable and can be easily...

Page 15: ...8B CLEANING LOWER STORAGE CABINET CONTINUED If equipped with tray slides the tray slides can be removed by lifting up on the front of the tray slide assembly to allow the front tray slide frame to cle...

Page 16: ...h drawers remove the drawers from the drawer frame module The drawer frame module can be removed by loosening the black clamping knob on the Cross Rail Locks and Liner Locks Pull the Cross Rail Locks...

Page 17: ...efrost cycle Use a soft cloth or sponge to clean the pan chiller Always exercise caution to avoid getting the fan assembly wet There are two drains in the pan chiller Both drains must be cleared clean...

Page 18: ...uired frequency of cleaning However both should be cleaned a minimum of once every three months Air must be able to freely circulate through the condenser Unit performance and operating efficiency are...

Page 19: ...coil must be cleaned regularly Remove the access panel using a phillips head screwdriver Carefully clean dirt and lint from the condenser coil using a vacuum cleaner or soft brush do not use a wire b...

Page 20: ...is iced up or dirty Prolonged and or frequent door openings or door s ajar Excessive load of warm food placed into lower storage cabinet 3 Lower storage cabinet not holding temperature Temperature co...

Page 21: ...NEVER dump water into the rail when cleaning This can overflow into the fan causing failure and the resulting service call 10 Do not use sharp utensils to clean the gaskets Wiping them down daily ensu...

Page 22: ...t charges are paid File claim for damages with freight agent immediately BLU fixtures manufactured by Kairak hold a 3 year parts and labor warranty Kairak holds a 5 year compressor warranty with a one...

Page 23: ...NOTES...

Page 24: ...500 S State College Blvd Fullerton CA 92831 Phone 714 870 8661 Fax 714 870 6473 www kairak com KAIRAK a division of ITW Food Equipment Group LLC All Rights Reserved Rev 5 10...

Reviews: