PaGE 6
KrP PrEP taBlEs
4. rEFrIGEratIon lInEs
(rEMotE unIts)
WarnInG: rEFrIGEratIon lInEs arE sHIPPED unDEr PrEssurE. usE cautIon
WHEn oPEnInG lInEs.
On remote units, refrigeration lines for suction and supply are located on the back of the
unit near the bottom. The suction line is marked “Suction” and is 3/8” copper tubing. The
supply line is 1/4” copper. See “Electrical Connections” section for wiring instructions.
If no holding charge is evident upon opening lines, contact Kairak Service and Parts
Department at 714-870-8661 immediately.
Cut refrigeration tubing with tube cutter (not a hacksaw) and deburr end of tube. Degrease
tubing prior to field connection. Use Silfos 5% for refrigerant line brazing. 50/50 or cold
solder is not acceptable.
For system charge, follow remote refrigeration system manufacturer’s instructions.
5. ElEctrIcal connEctIons
Refer to the wiring diagram shipped with the unit located inside the compressor
compartment or on the back of the unit.
corD connEctED unIts (self-contained models)
Plug the unit into a properly sized outlet. See data plate located inside storage cabinet
for circuit sizing.
WarnInG: tHIs MacHInE Is ProVIDED WItH a tHrEE-PronGED GrounDInG
PluG. tHE outlEt to WHIcH tHIs PluG Is connEctED Must BE ProPErlY
GrounDED. IF tHE rEcEPtaclE Is not tHE ProPEr GrounDInG tYPE,
contact an ElEctrIcIan.
PErManEntlY WIrED unIts (remote models)
A junction box located on back of the machine near bottom is provided for electrical field
connections. See wiring diagram shipped with unit on the back of the unit for electrical
ratings.