7o - AdjUstInG tHE dRAWER PERIMEtER HEAtERs:
This parameter allows the customer to turn ON and OFF the anti-condensate door/drawer
perimeter heaters. This parameter is set to the highest setting (100) at the factory so that
the door/drawer heaters stay on continuously. If you choose to have the door/drawer
heaters cycle on and off, lower this parameter to approximately 30. If condensation forms
around the door/drawers, increase the parameter until condensation stops. The exact
setting will vary depending on ambient conditions.
Follow the instructions to enter the customer access code on page 8.
When the control displays Thermostat Set High, press the down arrow
key until the control display reads
DewPoint Compensation Factor. Press
the set button . Press the arrow keys to adjust the factor to your desired
setting. When the display shows the factor you want press the set button . The
display will then read DewPoint Compensation Factor. You can use the up
or down arrow keys to scroll to the next parameter or press the alarm cancel
button to exit .
7. MIcRoPRocEssoR contRol
(cont.)
SET
SET
)
)
)
7P - AdjUstInG tHE RooM tEMPERAtURE oFFsEt:
The room temperature offset parameter allows a service technician or end user the
ability to have the display show a temperature that is within three degrees of the actual
temperature being read by the cabinet air sensor. This allows for continuity of reading
between different temperature reading devices. (i.e.: thermistor vs. thermocouple vs.
handheld thermometer) This parameter is preset at the factory to “-2.50F”.
Follow the instructions to enter the customer access code on page 8.
When the control displays
Thermostat Set High, press the down arrow key
until the control display reads
Room Temperature Offset. Press the set
button . Use the arrow keys
to adjust the offset to your desired setting.
When the display shows the offset you want press the set button . The display will
then read Room Temperature Offset.
You can use the up or down arrow keys to scroll to the next parameter, or press
the alarm cancel button to exit .