127
Engineering of electrical wiring
9.2.3 Insulation material selection for drainage pipe
➢
The insulation material should be flame retardant material, the flame retardancy of the material should
be selected according to the local law.
➢
Thickness of insulation layer is usually above 10mm.
➢
Use specific glue to paste the seam of insulation material, and then bind with adhesive tape. The width
of tape shall not be less than 5cm. Make sure it is firm and avoid dew.
9.2.4 Installation and highlights of insulation construction
➢
The single pipe should be insulated before connecting to another pipe, the joint part should be insulated
after the drainage test.
➢
There should be no insulation gap between the insulation material.
10. Engineering of electrical wiring
10.1 Highlights of electrical wiring installation
➢
All field wiring construction should be finished by qualified electrician.
➢
Air conditioning equipment should be grounded according to the local electrical regulations.
➢
Current leakage protection switch should be installed.
➢
Do not connect the power wire to the terminal of signal wire.
➢
When power wire is parallel with signal wire, put wires to their own wire tube and remain at least 300mm
gap.
➢
According to table in indoor part named
“the specification of the power” to choose the wiring, make sure
the selected wiring not small than the date showing in the table.
➢
Select different colors for different wire according to relevant regulations.
➢
Do not use metal wire tube at the place with acid or alkali corrosion, adopt plastic wire tube to replace it.
➢
There must be not wire connect joint in the wire tube If joint is a must, set a connection box at the place.
➢
The wiring with different voltage should not be in one wire tube.
➢
Ensure that the color of the wires of outdoor and the terminal No. are same as those of indoor unit
respectively.
Summary of Contents for KOB30U-18HFN32
Page 1: ...i KAISAI SUPER DC INVERTER SERIES Service Manual 2019 ...
Page 12: ...Indoor Units 11 Service Space 3 Service Space 1000m m 1000mm 1000m m 1000m m ...
Page 15: ...Indoor Units 14 Wiring Diagrams ...
Page 20: ...Indoor Units 19 Air Velocity Distributions Reference Data 30 42K Cooling Heating ...
Page 21: ...Indoor Units 20 Air Velocity Distributions Reference Data 48 55K Cooling Heating ...
Page 26: ...Indoor Units 25 Field Wiring 10 Field Wiring KCD 24HRF32 KCD 36HRF32 ...
Page 27: ...Indoor Units 26 Field Wiring KCD 48HRF32 KCD 55HRF32 ...
Page 49: ...Indoor Units 48 Field Wiring 10 Field Wiring 18k 55k ...
Page 53: ...Indoor Units 52 Service Space 3 Service Space ...
Page 55: ...Indoor Units 54 Wiring Diagrams ...
Page 72: ...Indoor Units 71 Service Space 3 Service Space ...
Page 73: ...Indoor Units 72 Wiring Diagrams 4 Wiring Diagrams KCA3U 12HRF32X ...
Page 82: ...Outdoor Units Outdoor Units 82 10 Field Wiring KCA3U 12HRF32X ...
Page 87: ...Outdoor Units 87 Wiring Diagrams 3 Wiring Diagrams KOB30 12HFN32X ...
Page 88: ...Outdoor Units 88 Wiring Diagrams KOB30U 18HFN32 ...
Page 89: ...Outdoor Units 89 Wiring Diagrams KOCA30U 24HFN32 ...
Page 90: ...Outdoor Units 90 Wiring Diagrams ...
Page 91: ...Outdoor Units 91 Wiring Diagrams KOD30U 36HFN32 ...
Page 92: ...Outdoor Units 92 Wiring Diagrams ...
Page 93: ...Outdoor Units 93 Wiring Diagrams KOE30U 48HFN32 KOE30U 55HFN32 ...
Page 118: ...Installation 119 Refrigerant pipe installation ...
Page 183: ...Controller Electrical Control System 184 ...
Page 184: ...Controller Electrical Control System 185 ...