Indoor unit installation
Installation
59
3.3.7 Change the air inlet direction
①
Take off ventilation panel and flange, cut off the staples at side rail.
②
Stick the attached seal sponge as per the indicating place in the following fig, and then change the
mounting positions of air return panel and air return flange .
③
When install the filter mesh, please plug it into flange inclined from air return opening, and then push up.
④
The installation has finish, upon filter mesh which fixing blocks have been insert to the flange positional
holes.