70-1201-KF20-1 0802

Do not measure high power line that might exceed 2kVA.
Do not exceed the maximum input value of each range.
Confirm that 

RANGE

 Switch is set to the correct position.

Read 

3. SAFETY PRECAUTIONS

carefully for safety measurement.

KF-20 is warranted in its entirety against any defects of material or workmanship 
under  normal  use  and  service  within  a  period  of  one  year  from  the    date  of 
purchase  of  the  original  purchaser.  Warranty  service  is  available  at 

KAISE 

AUTHORIZED  SERVICE  AGENCY 

through  your  local  dealer.  Their  obligation 

under this warranty is limited to repairing or replacing KF-20 returned intact or in 
warrantable defect with proof of purchase and transport charges prepaid.  

KAISE 

AUTHORIZED  DEALER

  and  the  manufacturer, 

KAISE  CORPORATION

,    shall 

not  be  liable  for  any  consequential  damages,  loss  or  otherwise.  The  foregoing 
warranty  is  exclusive  and  in  lieu  of  all  other  warranties  including  any  warranty  of 
merchantability, whether expressed or implied.
This warranty shall not apply to any instrument or other article of equipment which 
shall  have  been  repaired  or  altered  outside  of 

KAISE  AUTHORIZED  SERVICE 

AGENCY

, nor which have been subject to misuse, negligence, accident, incorrect 

repair  by  users,  or  any  installation  or  use  not  in  accordance  with  instructions 
provided by the manufacturer.

Check the battery connection, polarity, and capacity.
Confirm that RANGE Switch is set to the correct position.
Confirm  that  the  body  of  this  instrument  and  handle  insulators  of  the  Test 
Leads have no cracks or any other damages.
Check  if  any  noise  affects  the  instrument.  This  instrument  is  fully  shielded 
against noise, but possibly to be affected by very strong noise.

Repair service is available at KAISE AUTHORIZED SERVICE AGENCY through 
your  local  dealer.    Pack  the  instrument  securely  with  your  name,  address, 
telephone number and problem details, and ship prepaid to your local dealer.

KAISE AUTHORIZED DEALER

Product specifications and appearance are subject to change without 
notice due to continual improvements.

5-3. AC VOLTAGE MEASUREMENTS (AC-V)

WARNINGS




6-1. BATTERY REPLACEMENT

6-4. REPAIR

WARNINGS

WARRANTY

 1.
 2.
 3.
 4.
 
 5.
 

 1.
 2.
 3.
 
 4.
 

Replace the batteries when it is exhausted and "0

Ω

 Adjustment" does not work.

Check the following items before asking repair service.

To  avoid  electrical  shock,  detach  test  leads  from  circuit  when  when 
opening rear case for battery or fuse replacement.
Be sure to tighten the screw of rear case after the battery replacement

Detach test leads from the circuit.
Unscrew rear case. 
Remove rear case opening from meter side and slide to the upward.
Replace  an  exhausted  battery  into  a  new  1.5V  R6P  (AA)  battery  in  correct 
polarity.
Close rear case fitting from bottom to up, and tighten the screw.

422  Hayashinogo, Ueda City, Nagano Pref., 386-0156 Japan
TEL : +81-268-35-1600 (REP.)  /  FAX : +81-268-35-1603
E-mail : sales@kaise.com
http://www.kaise.com

5

6

7

8

fig. 10

6

MAINTENANCE

Do not measure over 300mA DC.
Do not exceed the maximum input value of each range.
Confirm that 

RANGE

 Switch is set to the correct position.

Read 

3. SAFETY PRECAUTIONS

carefully for safety measurement.

5-4. DC CURRENT MEASUREMENTS (DC-mA)

WARNINGS




Do not measure high power line that might exceed 2kVA.
Do not exceed the maximum input value of each range.
Confirm that 

RANGE

 Switch is set to the correct position.

Read 

3. SAFETY PRECAUTIONS

carefully for safety measurement.

WARNINGS




The  internal  protection  circuit  against  over  current  for  meter  movement  and  the 
internal circuit is installed. But, the instrument should be defective by such as over 
input measurement, or applying voltage to resistance or current range.

9. Protection Circuit

5-2. DC VOLTAGE MEASUREMENTS (DC-V)

Plug  Black  Test  Lead  into  "-  (COM)"  terminal  and  Red  Test  Lead  into  "+" 
terminal.
Set 

RANGE

 Switch to a desired 

DC-V

 range. 

NOTE :

 

Connect black test lead to 

 (earth) side and red test lead to 

 (positive) side 

of the measuring circuit.

NOTE : 

Connect the multitester 

IN PARALLEL

 to the circuit. 

NOTE : 

Use alligator clips for dangerous voltage measurement.

Read the meter on 

DC/AC

 scale referring to 

5-1. 7. Meter Scale Reading

」.

Detach test leads from the circuit.

To  measure  uncertain  voltage,  firstly  measure  the  approximate  value 
at  1200V  range,  then  change  the  switch  into  the  suitable  range. 
Detach test leads from the circuit before rotating 

RANGE

 Switch. 

1.

2.

3.

4.
5.

Plug  Black  Test  Lead  into  "-  (COM)"  terminal  and  Red  Test  Lead  into  "+" 
terminal.
Set 

RANGE

 Switch to a desired 

AC-V

 range. 

NOTE :

 

Connect black test lead to 

 (earth) side and red test lead to 

 (positive) side 

of the measuring circuit.

NOTE : 

Connect the multitester 

IN PARALLEL

 to the circuit. 

NOTE : 

Use alligator clips for dangerous voltage measurement.

Read the meter on 

DC/AC

 scale referring to 

5-1. 7. Meter Scale Reading

」.

Detach test leads from the circuit.

To  measure  uncertain  voltage,  firstly  measure  the  approximate  value 
at  1200V  range,  then  change  the  switch  into  the  suitable  range. 
Detach test leads from the circuit before rotating 

RANGE

 Switch. 

Installed  battery  is  for  inspection  purpose  and  might  be  exhausted 
earlier than the new battery.

300mA range is protected by 0.3A/250V fuse, but 60uA, 3mA, and 30mA 
ranges are not.
Do not measure voltage in 

DC-mA

 range.

Do not measure wall outlet or car battery by mistake.

1.

2.

3.

4.

5.

Do not measure voltage in 

Ω

 range.

When measuring in-circuit resistor, turn off the circuit to be measured and 
discharge the capacitors.

5-5. RESISTANCE MEASUREMENTS (

Ω

)

WARNINGS


6-2. FUSE REPLACEMENT

6-3. PERIODICAL CHECK AND CALIBRATION

WARNINGS

Always  use  the  specified  fuse.  Do  not  use  the  instrument  shorting  fuse 
holder or without using the fuse.
Be sure to tighten the screw of rear case after the fuse replacement.

Plug  Black  Test  Lead  into  "-  (COM)"  terminal  and  Red  Test  Lead  into  "+" 
terminal.
Set 

RANGE

 Switch to a desired 

Ω

 range.

When  measuring  in-circuit  resistor,  turn  off  the  circuit  to  be  measured  and 
discharge the capacitors.

0

Ω

 Adjustment 

Short-circuit  metal  pins  of  the  test  leads.  Turn 

0

Ω

  ADJ.  Knob

  until  the  meter 

points to "0

Ω

".

NOTE :

  0

Ω

 Adjustment is necessary for each time when 

Ω

 range is selected.

NOTE :  

0

Ω

 Adjustment does not work if the battery is exhausted. Replace it

              referring to

6-1. BATTERY REPLACEMENT

.

Connect  test  leads  to  resistor  to  be  measured  detaching  its  one  side  from  the 
circuit. 
Read the meter on 

OHMS

 scale referring to 

5-1. 7. Meter Scale Reading

.

NOTE :

  Read the scale directly when measuring in "x 1" range. In "x 100" 

              range, multiply the scale by 100, and in "x 1k" range, multiply by 1,000.

NOTE :  

For correct resistance measurement, select the range to point around 

              the center of 

OHMS

 scale.

Detach test leads from the resistor. 

1.

2.

3.

4.

5.

6.

7.

Do  not  test  non-specified  batteries  to  avoid  electric  shock  hazard  and 
serious damage to the instrument.
Do not test car battery.
Do not measure voltage or current in 

BAT

 range.

Battery  exhausted  level  can  be  tested  in  Hi  (1.5V  250mA),  or  Lo  (1.5V  50mA) 
ranges.
Testable batteries : 1.5V R20P (D), 1.5V R14P (C), 1.5V R6P (AA), 1.5V R03 (AAA)

5-6. 1.5V BATTERY TEST (BATT)

WARNINGS


Plug  Black  Test  Lead  into  "-  (COM)"  terminal  and  Red  Test  Lead  into  "+" 
terminal.
Set 

RANGE

 Switch to "Hi" or "Lo" of 

BAT

 range.

NOTE :

 "Lo" range applies 50mA, and "Hi" range applies 250mA to the battery. 

Confirm consumption current of the instruments that the battery will be used to 
select the proper testing range. 
Popular range selection : 1.5V R20P (D), 1.5V R14P (C) : "Hi" range
                                         1.5V R6P (AA), 1.5V R03 (AAA) : "Lo" range
Connect black test lead to 

 (earth) side and red test lead to 

 (positive) side.

Read the meter on 

BATT

 scale.

Meter points "

GOOD (blue)

" : The tested battery is good.

Meter points "

REPLACE (red)

" : The tested battery is exhausted and needs to 

be replaced.

NOTE :

 Even if meter points "REPLACE (red)" for 1.5V R6P (AA) battery tested 

in "Lo" range, it may be used with low consumption current instruments.

1.

2.

3.

4.

810-02  temperature  probe  (option)  is  necessary.  Measurement  range  is  -50

  to 

+250

.

5-7. TEMPERATURE MEASUREMENTS (

)

Plug  Black  Test  Lead  into  "-  (COM)"  terminal  and  Red  Test  Lead  into  "+" 
terminal.
Set 

RANGE

 Switch to 

TEMP (x100)

 range.

0

Ω

 Adjustment

Short-circuit  metal  pins  of  the  test  leads.  Turn 

0

Ω

  ADJ.  Knob

  until  the  meter 

points to "

CAL

" line on 

TEMP

 scale.

Remove test leads from the terminals, and insert 810-02 temperature probe.
Connect temperature probe to the object to be measured.
Read the meter on 

TEMP

 scale.

1.

2.

3.

4.

5.

6.

Plug  Black  Test  Lead  into  "-  (COM)"  terminal  and  Red  Test  Lead  into  "+" 
terminal.
Set 

RANGE

 Switch to a desired 

DC-mA

 range. 

            WARNINGS

 

Turn off the circuit to be measured and discharge the capacitors.
Connect black test lead to 

 (earth) side and red test lead to 

 (positive) side 

of the measuring circuit. 

NOTE : 

Connect the multitester 

IN SERIES

 to the circuit. 

NOTE : 

Using alligator clips is recommended for safety measurement.

Turn on the circuit to be measured.
Read the meter on 

DC/AC

 scale referring to 

5-1. 7. Meter Scale Reading

.

Turn off the measured circuit again and discharge the capacitors.
Detach test leads from the circuit.

1.

2.

3.
4.

5.
6.
7.
8.

NOTE :

 1.
 2.
 
 3.

 

DC Current and Resistance measurement cannot be made if fuse blows out.
This instrument contains one spare fuse inside the rear case.

Periodical  check  and  calibration  is  necessary  to  make  safety  measurements  and 
to maintain the specified accuracy. The recommended check and calibration term 
is  once  a  year  and  after  the  repair  service.  This  service  is  available  at  KAISE 
AUTHORIZED SERVICE AGENCY through your local dealer.

Open rear case referring to 

6-1. BATTERY REPLACEMENT

.

Replace a blowout fuse into a new one.

Fuse type :

 Fast-acting 0.3A/250V (

φ

5x20mm)

Close rear case fitting from bottom to up, and tighten the screw.

1200

1200

300

120

30

12

300

120

30

12

3

3

60

30 300

0.3

Hi

Lo

BAT.

×

1

×

100

×

1k

AC-V

DC-V

μ

DC

TEMP

TEMP

DC

5k

2k

1k

AC

DC
AC

BATT

TEMP

TAUT  BAND

1.5V VOLT

BATT

m

A

MADE  IN   JAPAN

NO.

DROP
PROOF

PROTECTION

10,000

V  AC

20,000

V  DC

20

10

5

30

15

6
3

50

10

4

2

100

200

5

2

1

50

0

0

0

0

20
8

4

25

10

5

30

12

6

250

200

100

50

0

-50

1.5

1.0

0.5

0

CA

L

OHMS

C  O  M

Ω

R  E

  P  L

  A  C  E

G  O  O

  D

UCHIDA

battery

KF-20

Red
Test Lead

Black
Test Lead

Red
Test Lead

Black
Test Lead

Red
Test Lead

Black
Test Lead

Red
Test Lead

Black Test Lead

fig. 6

fig. 7

fig. 9

fig. 8

1200

1200

300

120

30

12

300

120

30

12

3

3

60

30 300

0.3

Hi

Lo

BAT.

×

1

×

100

×

1k

AC-V

DC-V

μ

DC

TEMP

TEMP

DC

5k

2k

1k

AC

DC
AC

BATT

TEMP

TAUT  BAND

1.5V VOLT

BATT

m

A

MADE  IN   JAPAN

NO.

DROP
PROOF

PROTECTION

10,000

V  AC

20,000

V  DC

20

10

5

30

15
6
3

50

10

4

2

100

200

5

2

1

50

0

0

0

0

20
8

4

25

10

5

30

12

6

25

0

200

100

50

0

-50

1.5

1.0

0.5

0

CA

L

OHM

S

C  O  M

Ω

R  E

  P  L

  A  C  E

G  O  O

  D

UCHIDA

outlet

KF-20

1200

1200

300

120

30

12

300

120

30

12

3

3

60

30 300

0.3

Hi

Lo

BAT.

×

1

×

100

×

1k

AC-V

DC-V

μ

DC

TEMP

TEMP

DC

5k

2k

1k

AC

DC
AC

BATT

TEMP

TAUT  BAND

1.5V VOLT

BATT

m

A

MADE  IN   JAPAN

NO.

DROP
PROOF

PROTECTION

10,000

V  AC

20,000

V  DC

20

10

5

30

15
6
3

50

10

4

2

100

200

5

2

1

50

0

0

0

0

20
8

4

25

10

5

30

12

6

250

200

100

50

0

-50

1.5

1.0

0.5

0

CA

L

OHMS

C  O  M

Ω

R  E

  P  L

  A  C  E

G  O  O

  D

UCHIDA

Switch

KF-20

1200

1200

300

120

30

12

300

120

30

12

3

3

60

30 300

0.3

Hi

Lo

BAT.

×

1

×

100

×

1k

AC-V

DC-V

μ

DC

TEMP

TEMP

DC

5k

2k

1k

AC

DC
AC

BATT

TEMP

TAUT  BAND

1.5V VOLT

BATT

m

A

MADE  IN   JAPAN

NO.

DROP
PROOF

PROTECTION

10,000

V  AC

20,000

V  DC

20

10

5

30

15
6
3

50

10

4

2

100

200

5

2

1

50

0

0

0

0

20
8

4

25

10

5

30

12

6

250

200

100

50

0

-50

1.5

1.0

0.5

0

CA

L

OHM

S

C  O  M

Ω

R  E

  P  L

  A  C  E

G  O  O

  D

Resistor

KF-20

Rear Case

1.5V R6P Battery

Screw

Reviews: