10
EN
CONVERSION TO A DIFFERENT TYPE OF
GAS
Before converting the appliance for operation with a
different gas type, check which type of gas it is
currently set to operate with (adhesive label on
appliance).
For the correct nozzle diameter, refer to the relative
table in this booklet.
Conversion to a different gas type must be carried
out by qualified technicians and in conformance with
the requirements.
Conversion procedure:
x
Disconnect the electrical power supply to the
appliance,
x
Turn the knobs in the null position.
x
Replace the nozzles
1
with the
corresponding type of gas to be used (see
table «Nozzle table»).
x
R
e
move a knob of gas submission
2
.
x
R
e
move a plastic ring
3
.
x
To adjust to the minimum, turn the knobs in
the null position and use a screwdriver on the
screw placed on the tap
4
after turning the
tap to its minimum position. For LPG
(butane/propane) screw tight.
2
3
4
1