background image

About the measurement

The following methods are used for measurement of pollutants and parame-

ters:

CO2: 

Non-dispersive infrared (NDIR)

KM-100 module, PM2.5:

 Laser-based light scattering (mie principle)

KM-102 module, TVOC: 

Metal-oxide-semiconductor (MOS)

KM-102 module, temperature and relative humidity: 

CMOSens® technology

The Sensedge provides realtime measurements, thus it important to consider 

other factors that may influence sensor measurement when taking a reading 

of air quality. Human breath within several metres of the device will impact 

both CO2 and TVOC measurements, and physically touching and interacting 

with the Sensedge can have a measurable impact on temperature.

Changes in airflow or currents in an indoor space can all have a measurable 

impact on the readings of the Sensedge, and correct usage is vital for accurate 

and reliable readings.

Data buffer

The Sensedge takes readings of pollutants and measured parameters every 

second, and calculates a minute-by-minute average, which is recorded in the 

Sensedge’s onboard memory. When connected to the Internet, these readings 

are uploaded once per minute. Should the data connection be lost for a 

period of time, all readings will be stored in the data buffer, and automatically 

uploaded to the cloud when the Sensedge reconnects. There is no maximum 

to the number of historical readings that can be stored in the data buffer and 

uploaded upon reconnection.

Summary of Contents for Sensedge

Page 1: ...Sensedge Professional Indoor Air Quality Monitor Getting Started...

Page 2: ......

Page 3: ...ce 7 Setting the language 7 Connecting to Wi Fi 7 Setting a PIN code 7 Views 8 Views My Air 8 Views Data 8 Views Settings 9 General 9 General PIN 9 General Pair Device 9 Sensors 9 Data Export 10 Wi Fi...

Page 4: ...erra com support Externals and air flow Air is drawn into the Sensedge from both the modules on the lower side as well as the air intake on the upper side It is vital that neither side of the device i...

Page 5: ...ge Sensor modules Used to measure a variety of pollutants and other parame ters these sensors are interchangeable and modular Sensor modules The Sensedge utilises a modular design to allow for easy co...

Page 6: ...ting with the Sensedge can have a measurable impact on temperature Changes in airflow or currents in an indoor space can all have a measurable impact on the readings of the Sensedge and correct usage...

Page 7: ...Kaiterra logo appears on the screen Setting the language Upon first use the Sensedge will prompt users to select a language Scroll through the options using the touchscreen and confirm using the next...

Page 8: ...using the menu on the left side of the screen Views My Air This is the default view displayed when the Sensedge is powered on and provides an overview of realtime air quality Realtime pollutants in th...

Page 9: ...d from users at any point in time and anyone with access to the device may interact with it Require PIN Select Always to require the security PIN for all interaction with the device this should be cho...

Page 10: ...l and other spreadsheet software Data export via e mail will only transfer readings that are stored in the cloud and not readings that are stored locally on the device and unavailable in the cloud If...

Page 11: ...nguage of the device A number of languages are sup ported and may be modified at any point in time Upon change of language the device s screen may briefly dim as the interface is reloaded Time By defa...

Page 12: ...both new features as well as security upgrades available By default auto update is enabled so that upgrades will be automatically installed when they become available online It is highly recommended...

Page 13: ...gh the backplate Maintenance The Sensedge contains no customer serviceable components other than the modules inserted in the two module bays Neither the modules nor the Sensedge should never be opened...

Page 14: ...ion 1 KM 100 Module 8 PM2 5 Sensor Type Light scattering 350nm Precision 9 10 10 30 g m3 3 g m3 Resolution 1 g m3 Range 1 1000 g m3 Measurable particle size 0 3 2 5 m Connection Wi Fi 2 4Ghz Ethernet...

Page 15: ...defined upon fifteen minute averages Due to non uniform distribution of particulate matter fluctuations may occur at higher measurement frequency 10 The Sensedge is calibrated during the manufacturing...

Page 16: ...d if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular in...

Reviews: