background image

2.3 Requirement of operating site

 

 

This machine is designed for operating on the site: 

Voltage

 The steady-state AC power supply is 0.9

1.1 times of the rated    value. 

Frequency

    0.99

1.01 times of rated frequency (continuous working) 

                          0.98

1.02 times of rated frequency(short period working) 

Harmonics

 The sum of 2nd-5th distorted harmonic must not exceed 10% of RMS of voltage, maximum 

2% of RMS of line voltage is allowed to add to the sum of 6th-30th harmonic. 

Unbalanced voltage

 of 3-phase power supply       

Negative sequence component are not allowed to exceed 2% of the positive sequence component.   

Short-circuited protection

 and

 incoming line

 

The machine shall have short-circuited protective device at the power supply end by the end-user, the 

rated current shall be 5A, and the diameter of the incoming line of the power supply must not be less 

than 1.5mm

(single phase) and 1.5mm

2

 (PE). 

Overvoltage protection 

 

Overvoltage protection device shall be provided in the power supply line by the end user.   

- The height above sea level of the machine installation doesn’t exceed 1000m; 

- The ambient temperature range of air is 5

℃~

40

.   

- The relative humidity doesn’t exceed 50% at a maximum temperature of +40 

 . 

Higher relative humidity may be permitted at lower temperature (e.g.90% at 20

- Lighting of the work zone should be at least 500lux(provide by end user). 

- The installation site of the machine shall be away from undesirable vibration, shock or bump. 

 

3 Description of machine 

3.1 Description 

 

Circular Saw consists of 6 models which have the same construction and each of which meets the same 

high quality requirements. 

The constructive differences apply to the application and the specific wishes of the user. 

All versions are standardly equipped with a machine based with incorporated cutting oil tank and pump. 

All versions are fitted with a tolerance-free long-life worm and worm wheel. The worm gear runs in an oil 

bath case and is virtually maintenance-free. 

All versions are fitted with a double, self-centring material vice. 

The machine can mitre, slot and cut recessed corners in both directions. For this !ast form of operation it 

is of special importance that the saw unit as a whole can turn around its axis. 

The machine can saw various profiles in various dimensions and cross-sections. A survey of these can 

be found in chapter 5,3 "Sawing capacity", 

The patented protective guard opens and closes automatically. The saw blade can easily be exchanged. 

The machine as standard is equipped with an adapter for the saw blade (see technical data). If ordered a 

Summary of Contents for CS-12

Page 1: ...COLD SAW Model CS 12 CS 14 Opertation Manual...

Page 2: ...wet environment Never work without a safety guard Wear eye protection device Dot work with trailing pieces of clothing which could be caught by moving parts Preferably wear ear mufflers and mask durin...

Page 3: ...all claims relating to the faults concerned will expire The purchaser s appeal for guarantee does not relinquish his contractual obligations towards us As long as the purchaser does not fulfil his co...

Page 4: ...temperature of 40 Higher relative humidity may be permitted at lower temperature e g 90 at 20 Lighting of the work zone should be at least 500lux provide by end user The installation site of the machi...

Page 5: ...nd put the basic to another case 6 As this machine s weight is 110kg it is recommended that the machine should be Transported with help of lifting device In fig 3 04 Warning Tighten all locks before o...

Page 6: ...uge of the saw head whether it contains sufficient oil if necessary fill up fig 4 01 see arrow Install the cover at the rear of the machine base Install the saw blade see chapter 5 4 4 2 Non recurrent...

Page 7: ...ld be always performed by authorized electricians 1 Make sure that the correct voltage is supplied to the machine 2 Set up the electrical connections according to the attached circuitry Connect the el...

Page 8: ...case of a second cut of the same tooth This can cause the saw blade to jam and break A pitch which is too large will cause the sawing tooth to hack as a result of which teeth can break free For the sa...

Page 9: ...rmal way it would get hot expand and become wider than the width of the cut This wouid cause it to get stuck as a result of which the chip could not be removed from the cut The finishing tooth must be...

Page 10: ...close the safety guard 5 5 Saw feed Manual saw feed The saw feed is determined by hand The saw is lowered onto the material by means of the handle Press the saw blade firmly onto the material without...

Page 11: ...Do not use unnecessary force a slight pull will suffice Before clamping the material check whether the saw is running completely clear between the jaws of the material vice Place the sieel vice jaws a...

Page 12: ...d it needs to be cleaned or replaced Check the oil level in the saw head every week Check the oil level of the saw feed tank and refill if necessary see chapter 6 3 Check the oil bowl and the water se...

Page 13: ...Remedy Excessive bouncing or breaking of the saw 1 Speed an or saw feed too high 2 Teeth blunt tooth cavities too small 3 Wrong coolant 4 Saw jolts because chips remain in the saw cavity cold welding...

Page 14: ...Qty 101 Pedestal 1 109 Sticker electro 1 102 cover 1 110 Sticker general 1 103 support pump 1 111 Pump set 230 40QV50HZ 1 104 screw 6 x 12 4 112 Filter 1 105 Spring washer 6 6 113 Screw M6x12 106 Scre...

Page 15: ...cale 1 202 Type Shield 2 203 Spring 2 204 Rivet 10 2 205 Screw M10x100 2 206 Nut M10X25 4 207 Filter 1 208 Spring fixed plate 1 209 Spring fixed plate 1 210 Washer 4 220 Base plate 1 221 Swivel block...

Page 16: ......

Page 17: ...4 306 Rubber cover 1 341 Handle rod knob 3 307 Pipe hoop 1 342 Knob 3 308 Nut 1 343 Plastic cover knob 1 320 Pin 2 344 Boss 1 321 Knob 1 345 Guiding shaft 2 322 Mitre handle complete 1 346 Vice base...

Page 18: ......

Page 19: ...using 350 1 407 Circlip 1 434 Worm wheel 1 409 Stopper stifled 1 435 Bush 1 410 Bearing 1 436 Circlip 1 416 Sunken key 1 437 O ring 1 418 Ring 1 438 Socket screw 3 419 Dowel pin 2 439 Bearing block 1...

Page 20: ......

Page 21: ...g rod 1 502 Hinged guard 1 513 Bracket 1 503 Hinged guard 1 514 Ring 2 504 Ring 1 515 Socket head screw 1 505 Coupling rod 1 518 Lever 1 506 Ring 8 519 Star knob 2 507 Tap cock 1 521 Adjusting rod 3 5...

Page 22: ...escription Qty Part No Description Qty 612 Tie bar complete 1 646 Nut 4 614 Switch handle 1 647 Pinion 1 615 Nut 1 648 Lock nut 1 631 Sunken key 1 655 Motor 1 644 Screw 2 657 Bolt 1 645 Ring 4 658 Sto...

Page 23: ...78 676 0 OFF 1 M O 7 H I G H 2 Part No Description Qty 670 Switch box 1 671 Cover 1 672 Sealing tape 673 Screw M4x10 4 674 Screw M5x12 4 675 Spring washer 4 677 Motor switch contactor Dahlander switch...

Page 24: ......

Page 25: ...Note This manual is only for your reference Owing to the continuous improvement of the machine changes may be made at any time without obligation on notice...