background image

0150-0238B 

2-1 

Kalatel DSR-1000eZ 

2  U

SER 

O

PERATIONS

 

2.1  Recording 

RECORD

 

To begin recording, press the 

Record

 button.  

RECORD

 will be indicated for 

three seconds, near the upper left hand corner of the primary monitor.  The 
unit always starts recording at the end of the previously recorded data. 

Recording will continue until: 

• 

Another mode is selected (Play mode, Reverse Play,or Stop 
mode). 

• 

The disk is full (In No Overwrite and Overwrite Once modes). 
See section 

5.1 Advanced Menu 

 Disk Overwrite Mode

 on 

page 5-1, for details regarding Disk Overwrite modes. 

 

Record button

 

Normal Recording 

SPEED

REC/PLAY

 

The unit records at the normal record speed until an alarm condition is detected.  
The normal record speed is indicated on the monitor if the display option is enabled, 
and can be altered using the 

Up/Down Record Speed

 buttons, or in the menu 

system. 

For information about altering the normal record speed from the menu system, see 

Main Menu 

 Record Settings 

 Normal Record Speed

, on page 4-7 of the 

Operator Programming section of this manual. 

The normal record speed can be altered while the unit is recording.  The unit will 
continue recording while the menu system is active. 

Record Speed 

buttons

 

 

Alarm Recording 

ALARM

 

When an alarm condition is detected, the unit automatically switches to the 
alarm record speed.  The alarm condition is indicated in several ways: 

• 

With the word 

ALARM

, displayed on the primary monitor, near the 

upper left hand corner of the screen. 

• 

With the internal buzzer (if activated in the menu system). For 
information about activating the internal buzzer during alarms, see 

Main Menu 

 Alarms

 on page 4-3 of the Operator programming 

section of this manual. 

• 

By an external device, connected to the alarm output of the unit (if 
the unit is installed that way). 

Alarm Indicator

 

The alarm record speed cannot be changed using the 

Up/Down Record Speed

 buttons on the front 

panel.  The alarm record speed must be changed in the menu system. For information about altering 
the alarm record speed, see 

Main Menu 

 Record Settings 

 Alarm Record Speed

, on page 4-7 

of the Operator Programming section of this manual. 

The unit returns to the normal record speed when the alarm condition ends. 

Summary of Contents for DSR-1000eZ

Page 1: ...K Ka al la at te el l D DS SR R 1 10 00 00 0e eZ Z Single Channel Color Digital Video Recorder User Manual...

Page 2: ...ay be illegal to dispose of this battery improperly under local state or federal laws Check with your local waste management officials for disposal and recycling options CAUTION Electrostatic Sensitiv...

Page 3: ...tten consent of GE Interlogix All information and specifications furnished by GE Interlogix are believed to be accurate and reliable No responsibility is assumed by GE Interlogix for neither its use n...

Page 4: ...Kalatel DSR 1000eZ iv 0150 0238B...

Page 5: ...STEM 3 1 4 OPERATOR PROGRAMMING 4 1 4 1 Main Menu Time Date 4 1 4 2 Main Menu Alarms 4 4 4 3 Main Menu Timer Settings 4 5 4 4 Main Menu Record Settings 4 6 4 5 Main Menu Display Settings 4 8 4 6 Main...

Page 6: ...ER 6 1 6 1 WaveBrowser Overview and Controls 6 2 6 2 DSR WaveLink 6 4 6 2 1 Functionality 6 4 6 3 Upgrading the DSR with WaveBrowser 6 5 7 RS 232 REMOTE PROTOCOL 7 1 8 FACTORY DEFAULTS 8 1 9 TECHNICAL...

Page 7: ...Continuous Recording in Disk Overwrite mode Video Archiving via the unit s SCSI port Access to Live or Recorded video via the Ethernet Ethernet option only Continues Recording while Archiving or trans...

Page 8: ...t to rain or moisture Moisture can damage the internal components Do not install this unit near sources of water Chassis You can place other equipment on top of the unit if it weighs less than 35 poun...

Page 9: ...uttons Press these buttons to increase or decrease the Record or Playback speed 8 Combination Menu and Enter button Press the lower half of the button the Menu button to enter the Menu system Also use...

Page 10: ...15mV 600 Ohms Unbalanced 7 Video In Composite video input with BNC style connector Video Out Composite video output with BNC style connector Ethernet Port Ethernet models only Wire Type CAT5 Connector...

Page 11: ...unit is equipped with a SCSI port for connecting external archive devices The unit only supports a single SCSI device The SCSI ID must be set to 0 The SCSI bus must be terminated otherwise the system...

Page 12: ...all accessories to the Accessories PCB Do not attempt to wire accessories directly to the DB 9 connector If the Accessories PCB is lost or missing contact GE Interlogix Customer Service for a replace...

Page 13: ...en activated Compatible with the Disk End Out signal from a second unit Input Active Low TTL w pull ups or Normally Open Relay High 5V 12V tolerant Low Ground Minimum Duration 0 5 Seconds Alarm Record...

Page 14: ...es of recording space left on the hard disk It will also be activated if a DAT or AIT tape archiving device is connected and the tape end is encountered The DSR 1000eZ must be in Record mode with Back...

Page 15: ...e three fields 3 Press the Enter button to confirm the selection 4 To Save the changes and Exit the menu Use the Jog to select OK then press the Enter button OR 5 To Exit the menu without making chang...

Page 16: ...other device will cause the unit to activate an alarm condition Whether the internal buzzer is activated during an alarm condition Alarm Settings Hardwire Alarm Enable Teletext Alarm Disable Alarm Bu...

Page 17: ...Operator Programming section of this manual The normal record speed can be altered while the unit is recording The unit will continue recording while the menu system is active Record Speed buttons Al...

Page 18: ...recording session Playback is indicated As PLAY near the upper left hand corner of the primary monitor for three seconds Play Forward button Reverse Play REVERSE PLAY To begin reverse playback press...

Page 19: ...corner of the primary monitor for three seconds Jog Shuttle Pause PAUSE During playback press the Pause button to pause playback and display a single frame on screen Pause is indicated As PAUSE near t...

Page 20: ...to navigate highlight START SEARCH then press the Enter button The Search Results window will appear For information about selecting a recorded event see Selecting from the Search Results in this sect...

Page 21: ...h by placing an X in the check box 3 Press the Enter button at any time to exit Edit mode Starting the Search Using the Shuttle to navigate highlight the START SEARCH parameter then press the Enter bu...

Page 22: ...Kalatel DSR 1000eZ 2 6 0150 0238B...

Page 23: ...utton A Pop up or Pull down menu will appear Pull down Menus Pull down menus are the top level menus Make a selection in a Pull down menu to enter the appropriate sub menu typically a Pop up menu Chan...

Page 24: ...rmat Set Date Format Set Time Set Date Set Region Set Network Time Protocol Use this menu to specify The time format 12 or 24 hours The date format MM DD YY DD MM YY or YY MM DD The time The date Set...

Page 25: ...peed Alarm Record Speed Video Quality Use this menu to specify Which video input on the back panel is activated Color or Monochrome recording The record speed during Normal recording The record speed...

Page 26: ...enu password Use the Jog to select a character then use the Enter button to complete the selection and move to the next character 3 Pressing the Enter button on the last character will complete the pa...

Page 27: ...d briefly in this section For complete information about installer programming in the Advanced menu see section 5 o Advanced Menu Disk Overwrite Mode Disk Overwrite Mode Select Mode Continuous Overwri...

Page 28: ...of 1pps or faster o Advanced Menu Auto Delete Mode Use this menu to program the Auto Delete Mode The options available are from 7 to 99 days and Off 30 days is the default setting ADM will change Are...

Page 29: ...ed that an NTSC input signal is attached None Kalatel Robot DM Philips Pelco Sanyo Philips REO Navco ATV ATV QSP Vista VLM QSI 1700 Diebold Panasonic o Advanced Menu Adjust Picture Use this menu to sp...

Page 30: ...g the built in WaveBrowser See section 6 Firmware Upgrade WARNING Do not power off unit until the operation is done Do you want to continue OK CANCEL To upgrade the DSR from this menu requires the fol...

Page 31: ...te Set Time Format Time Format Setup Select Format 12 HOUR To set the Time format use the Jog to select the desired Time format Format the time as either 12 HOUR 24 HOUR Press the Enter button to conf...

Page 32: ...button OR 5 To Exit the menu without making changes Use the Jog to select CANCEL then press the Enter button o Main Menu Time Date Set Date Date Setup MM DD YY DAY 12 17 00 SUN CANCEL OK To set the Da...

Page 33: ...l Settings CANCEL OK The clock will only be automatically adjusted once on a given time and date If you manually set the clock back before the last DST change the time will not get automatically adjus...

Page 34: ...R 1000eZ is compatible with the following styles of Multiplexers Kalatel Philips Robot Pelco Sanyo Philips REO ATV ATV QSP Vista VLM QSI 1700 Diebold Panasonic Connecting to Dedicated Micros DM When c...

Page 35: ...e Month 1 through 31 Day of the Week Monday through Sunday Range of Days All Weekdays Monday Friday All Weekend Days Saturday Sunday Monday Sunday Everyday 4 When finished entering the Date use the Sh...

Page 36: ...e to navigate highlight the ON OFF parameter of the event you wish to delete 2 Press the Enter button to enter the Edit mode 3 Use the Jog to select DEL from the menu 4 Press the Enter button to confi...

Page 37: ...Normal Record Speed Pictures Per Second 5p Use the Jog to select the desired Normal Record Speed Normal Record Speeds NTSC 60 30 20 10 5 3 2 1 0 5 0 2 0 1 0 0 PAL 50 25 17 10 5 3 2 1 0 5 0 2 0 1 0 0...

Page 38: ...Format is located in the Advanced Menu 4 5 Main Menu Display Settings Current Time Date Record Capacity Archive Status Last Alarm Playback Time Date Use this menu to specify what status information wi...

Page 39: ...ither ARCHIVE NOT CONNECTED ARCHIVE READY ARCHIVE NOT READY Use the Jog to select ON or OFF Press the Enter button to confirm the selection and exit the menu OR Press the Menu button to exit the menu...

Page 40: ...se the archived data o Main Menu Archive Setup Selective Archive The Selective Archive feature allows the user to archive recorded data from the hard disk onto a CD DAT AIT RAID or DVSe See the Archiv...

Page 41: ...e Shuttle to navigate highlight the TIME parameter then press the Enter button The unit will enter Edit mode 2 Use the Jog to change the start and stop time values Use the Shuttle to navigate among th...

Page 42: ...ecorded event by placing an x in the check box Starting the Archive Process Archiving To begin archiving press the Search button The Archiving progress bar will appear Press the Enter button to cancel...

Page 43: ...se the Shuttle to navigate among the different parameters 3 To activate the start or stop date parameter use the Jog to place an X in the check box 4 Press the Enter button at any time to exit Edit mo...

Page 44: ...ize MB 279 x 67 x Selected 383 MB Available on Target Medium 652 MB ENTER to play SEARCH to restore o Main Menu Archive Setup Background Archive OFF ON With the Background Archiving Feature turned ON...

Page 45: ...he data this message box will appear Press the Enter button to acknowledge the message and complete the deleting process Archive medium erased OK 4 7 Main Menu Advanced Menu Password Box Please Enter...

Page 46: ...Kalatel DSR 1000eZ 4 16 0150 0238B...

Page 47: ...Overwrite o Advanced Menu Disk Overwrite Mode No Overwrite Physical Start and End of Disk Unit Stops Recording when this point is reached Previously recorded data Previously recorded data New recorde...

Page 48: ...button The unit will continue recording again when the user presses the Record button Overwrite Once Mode o Advanced Menu Disk Overwrite Mode Continuous Overwrite Functions of Continuous Overwrite mo...

Page 49: ...CANCEL by pressing the Enter button CANCEL o Advanced Menu Disk Maintenance Erase Caution Erasing the disk removes recorded data without the possibility of restoring it To begin erasing the disk use...

Page 50: ...Ethernet Settings Modem Settings Use thus menu to specify The data transfer rate for the RS 232 serial port The units Ethernet network connection settings Ethernet units only The Modem connection set...

Page 51: ...TCP MTU Size Select from Standard 1400 and 1200 The MTU describes the maximum possible TCP packet size Standard 1500 is optimal for most ethernet network environments Ethernet Settings CANCEL OK Hostn...

Page 52: ...r of the menu 2 Press the Sequence button to select the desired character bank 3 Rotate the Shuttle to navigate the Modem Init String 4 Rotate the Jog to select a character from the character bank 5 U...

Page 53: ...its Certain menu items may be grayed out and unavailable under certain circumstances The Vista VLM is grayed on the menu to the right because the DSR 1000eZ has auto detected that an NTSC input signal...

Page 54: ...decrease to saturation 3 To Save the changes and Exit the menu Use the Shuttle to select OK then press the Enter button OR 4 To Exit the menu without making changes Use the Shuttle to select CANCEL t...

Page 55: ...The New Password Has Been Accepted OK If the password in the Confirmation Box matches the password from the Password box this message will appear Press the Enter button to select OK and exit the menu...

Page 56: ...0 469 1676 Selecting OK will put the DSR 1000eZ into Firmware Upgrade mode The unit may now be programmed using WinFlash The Operation may be cancelled by powering off the unit as long as WinFlash has...

Page 57: ...igned ActiveX controls and Initalize and Script ActiveX controls not marked as Safe are set to Prompt 6 Click the OK button 7 Click on the Yes button in the Warning message 8 Click the OK button in th...

Page 58: ...The Drop Down Volume List Allows the selection of available Disk volumes The Main Viewing Area Pictures are displayed in this area in Multi Camera and Single Camera formats Picture display order is ac...

Page 59: ...to enable live viewing before connecting 12 Connect Disconnect button Click on this button s to connect to the unit 13 Number buttons Press any of these buttons to call up individual cameras for displ...

Page 60: ...een 1 Camera 1 16 Camera 16 or the type of the multiscreen display 100 Multiscreen 16 large 101 Multiscreen 16 small 102 Quad screen c 10 Size s n For fullscreen camera describes the size of the displ...

Page 61: ...h Microsoft Internet Explorer version 5 5 or later via ethernet cable 3 The IP address of the DSR 4 WaveReader software must NOT be connected to the DSR Please exit all non essential software on the P...

Page 62: ...h and filename Click on the Send File button Step 5 Click on the Confirm Button A progress bar will appear PLEASE WAIT FOR THE PROGRESS BAR TO FINISH THEN WAIT FOR CONFIRMATION Click on the Reboot but...

Page 63: ...Ex 02 50 41 55 03 Fast Forward Sx FWD Ex 02 46 57 44 03 Rewind Sx REW Ex 02 52 45 57 03 Frame Forward Sx FAD Ex 02 46 41 44 03 Frame Reverse Sx RAD Ex 02 52 41 44 03 Play Reverse Sx RPL Ex 02 52 50 4C...

Page 64: ...digits of the year for the year value For example 2001 is entered as 01 Time is always designated in Military Time Example In this example 14 39 on December 25 2000 is used to demonstrate the Set Cloc...

Page 65: ...equest Sx SMS Ex 02 73 4D 73 03 ASCII Status Response Messages Command ASCII String Model Name Response Sx MLN DSR 1000eZ 2000e Ex Software Version Number Response Sx SVN 1 18 Ex Sx RMS 0 Ex Not Recor...

Page 66: ...Kalatel DSR 1000eZ 7 4 0150 0238B...

Page 67: ...Auto Delete Mode Off Background Archive Mode Off Video Input Composite Front Panel Locked Off Brightness 50 Contrast 50 Saturation 50 Display Current Time and Date Off Display Record Capacity Off Dis...

Page 68: ...Kalatel DSR 1000eZ 8 2 0150 0238B Function Setting WINS Disabled Audio Record Setting Off...

Page 69: ...9 Male See Section 1 8 Accessories Port SCSI Port 50 Way High Density SCSI connector RS 232 Serial Port DB 9 Male DTE Connection Composite Video In BNC connector See caution below Composite Video Out...

Page 70: ...Data Time and Date Video Loss Playback Speed Part Numbers Accessories PCB 0900 0127 User Manual 0150 0238 Archiving Addendum 0150 0145 WaveReader Software CD Optional 0151 0005 WaveReader Software Ma...

Page 71: ...Return Material Authorization number RMA The unit s serial number must be provided before a RMA number can be issued Units returned to the factory for service must have freight and insurance prepaid a...

Page 72: ...ed For all non warranty repairs the customer will be billed for parts labor and shipping Labor will be billed in half hour increments Note Customers requesting an estimate prior to repair will be noti...