2.3 Three safety measures for the
gas fire
1. The flame is detected due to
electronic ionisation measurement
Should the gas fire be unable to
detect a flame during ignition, the
gas supply will be interrupted for one
minute. A new ignition attempt will
follow automatically. To interrupt
automatic ignition attempts: Press
the
button to switch off the
fireplace directly and depress this
button for approximately 10 seconds.
2. 24 hour security
The appliance will stay in a blocked
position if no flame is detected after
three automatic ignition attempts
(error code 08A). The block will take
effect after one ignition attempt
with gas type NZLP. This block can
twice be unlocked manually with
the remote control. If no flame is
detected after two manual releases,
the appliance will remain blocked for
24 hours (a ‘lock-out’, code 08F). In
that case, you may not use the gas
fire for
24 hours.
3. Overpressure protection
The gas fire is equipped with
overpressure protection to minimise
risk. Should explosive ignition occur,
the glass panel on the front topside
will open to reduce the pressure.