background image

13

3.  Description

The following sections describe the 
gas fire:
-     Description of the gas fire. 

3.1  Gas fire description

Kalfire gas fires are internationally 
renowned for their realistic, enchanting 
flames.  Kalfire appliances are easy 
to operate and maintain. Kalfire 
balanced-flue gas fires are equipped 
with an innovative Prestige or 3D 
burner, enhancing their environmental 
friendliness, sustainability and 
economy.

Balanced­flue gas fires

The patented Prestige burner radiates 
a realistic impression of wood fire. 
The Prestige burners are integrated 
in the ceramic log sets stacked in 
the appliance in pyramid form. This 
creates the impression of a high and 
voluminous flame pattern. 

The Kalfire GP can be delivered with 
the Natural Spark Generator (optional). 
This ensures that sparks emanate from 
the burning flames in a natural manner, 
and continue to burn slowly. This spark 
generator option is mounted inside the 
gas fire during manufacture by Kalfire 
and cannot be added at a later stage.

The Kalfire GP can also be delivered 
with an optional hybrid function. The 
gas fire’s fuel bed is equipped with LED 
lighting that simulates a bed of natural 
embers. The lighting generates an 
atmospheric imitation of the glow of a 

real wood fire. The hybrid function can 
also be switched on separately without 
engaging the Prestige burner.

The Kalfire G with a 3D burner 
generates an elongated and horizontal 
flame pattern, well suited to a modern 
household interior. The 3D burner offers 
a particularly attractive and true-to-life 
flame pattern. Kalfire G gas fires are 
delivered with a standard or optional 
luxury ceramic log set, white stones, 
grey pebbles or cryptonite.

Smooth transition between gas fire 
and surround

The balanced-flue gas fires are easy 
to align with the household interior 
during installation. The gas fire stone, 
often made from natural stone, can 
continue along the outer edge of the 
gas fire with the help of stone supports. 
The side walls can be fluidly finished in 
the surround of the gas fire. The back 
wall can be extended to outside the gas 
fire, meaning the metal lining remains 
invisible. 

Operation

If the house is equipped with a home 
automation system, then operation of 
the appliance can be integrated into 
that system.

Summary of Contents for G80/48F

Page 1: ...User instructions BALANCED FLUE GAS FIRES DON T COMPROMISE AU...

Page 2: ......

Page 3: ...Balanced flue gas fires Kalfire G80 48F Kalfire G85 44C Kalfire G90 44S Kalfire G160 41F Kalfire G165 37C Kalfire G170 37S for gas type NG ULPG and NZLP Version 03 2021...

Page 4: ......

Page 5: ...and removing the 30 guard mesh screen Contents 1 General information 7 1 1 Foreword 7 1 2 Pictograms 8 1 3 Warranty 8 2 Safety 10 2 1 Safety instructions for decorative elements 10 2 2 Safety related...

Page 6: ...6...

Page 7: ...the account of the user Copyright 2020 Kalfire B V Gelo rveldweg 21 Belfeld The Netherlands 1 General information The following sections provide general information about the gas fire Foreword Pictog...

Page 8: ...rranty 6 Should disruption occur within the warranty period caused by a manufacturing error or material defect Archifire Fireplaces will deliver the components needed for repair to the technical fitte...

Page 9: ...ical fitter approved by Archifire Fireplaces be unable to rectify the problem covered by the warranty then he is entitled upon his own express desire to requestArchifire Fireplaces to assume responsib...

Page 10: ...e materials such as curtains and furniture are at least 100 cm from the fireplace If a fireguard is used this distance must be at least 40 cm 2 Safety The following sections provide safety information...

Page 11: ...XPLOSION Fumes and or gas leaks can cause life threatening situations Fumes can be the cause of carbon monoxide poisoning and gas leaks are an explosion risk If you notice fumes or gas take the follow...

Page 12: ...ty The appliance will stay in a blocked position if no flame is detected after three automatic ignition attempts error code 08A The block will take effect after one ignition attempt with gas type NZLP...

Page 13: ...livered with an optional hybrid function The gas fire s fuel bed is equipped with LED lighting that simulates a bed of natural embers The lighting generates an atmospheric imitation of the glow of a r...

Page 14: ...f the gas fire Replacing the batteries Using the iMatch remote control Setting the day and time Confirming the transmission strength Switching the gas fire on and off Adjusting the flame intensity Sel...

Page 15: ...fications such as disruptions 9 Warning signals related to disruptions 10 Time segments 11 Thermostat mode 12 Manual programme default mode Buttons a and buttons b Left button and right c Centre butto...

Page 16: ...will stop flashing after the ignition programme 6 The gas fire flame is alight and operational 7 Press for approximately two seconds to extinguish the gas fire flame 4 3 Setting day and time Setting d...

Page 17: ...8 The flame intensity can also be displayed by the flame intensity indicator The ECO mode has a modulating effect on flame intensity higher or lower This accentuates the visual effect and user comfor...

Page 18: ...ese are indicated by switch on times ON 1 2 3 and switch off times OFF 1 2 3 The set programme will run daily 1 Check if the hand transmitter is set at the right time if you are not happy with the tim...

Page 19: ...place is burning but also when it is not Potential causes can be Smoking materials in the fireplace especially in the beginning air contamination quality of the type of gas etc Conditions Filth and st...

Page 20: ...smaller than 5 Carefully clean the glass use sufficient moisture avoid pressure and rub the substance from top to bottom to prevent cleaning detergent to remain on the glass Continuously dry the glas...

Page 21: ...eps explained in step 3 in reverse order Lock the door by moving the handles down Twist the metal cover strips step 1 back into its original position by using the protruding lip at the upper side of t...

Page 22: ...les down Twist the metal cover strips step 3 back in its original position by using the overlapping edge on the upper side of the strip and fold the metal cover strip down Install the 5 1 4 Door disma...

Page 23: ...the gas fire The waiting time must be respected also after a power interruption guard mesh screen See Annex A 3 5 2 Malfunctions Malfunctions can be organised in five categories 1 Permanent malfunctio...

Page 24: ...mulate the synchronisation speed Supply power back to the cable The entire light will start flashing once per second Should the gas fire is provided with a hybrid function and or NSG detach the HCB ca...

Page 25: ...chnical unit does not flash 1 Check power supply on the mains 230VAC 2 If this is correct check replace the VDC transformer and or automatic burner relay In case the light on the automatic burner rela...

Page 26: ...burner In case no gas ema nates from the burner check for gas supply up to the technical box measure pre pressure 4 In the presence of pre pressure check whether the cables running from the automatic...

Page 27: ...ic burner relay 34F Insufficient voltage 1 Measure mains voltage 220VAC 2 Measure outgoing transformer voltage 24 VDC and 12 VDC 3 If the outgoing voltage is lower than 20 VDC or 10 VDC replace the tr...

Page 28: ...28 A Appendices A 1 Wiring diagram HDIMS Ionisation AUX enable OPEN enable 24V Ground Stud KF00370 Wiring Diagram Hybrid Shut Down Switch Domotica iMatch Fig 11 Technical box...

Page 29: ...eldweg 21 NL 5951 DH Belfeld Certifies that the following Kalfire appliances model gas fire Kalfire G80 48F G85 44C and G90 44S Kalfire G160 41F G165 37C and G170 37S are in compliance with the applia...

Page 30: ...30 A 3 Installing and removing the guard mesh screen Installing the guard mesh screen front models Fig A fireplace with loose guard mesh screen Fig B fireplace with guard mesh screen in place...

Page 31: ...he guard mesh screen front models G80 48F and G160 41F Detail guard mesh screen is removed with the help of a guard tool Fig A fireplace with guard mesh screen in place Fig B fireplace with loose guar...

Page 32: ...32 Installing the guard mesh screen corner and 3 sided models G85 44C G90 44S G165 44C G170 44S Fig A fireplace with loose guard mesh screen Fig B fireplace with guard mesh screen in place...

Page 33: ...33 Removing the guard mesh screen corner and 3 sided models G85 44C G90 44S G165 44C G170 44S Fig A fireplace with guard mesh screen in place Fig B fireplace with loose guard mesh screen...

Page 34: ...34...

Page 35: ...35...

Page 36: ...Gelo rveldweg 21 5951 DH Belfeld info kal fire com KALFIRE COM DON T COMPROMISE REF V03 2021 AU 621015...

Reviews: