26
Error code
Cause
Solution
08A
No
ionisation
measure-
ment during
ignition.
A flame is visible during ignition
1.
Check if the ionisation pen is completely unobstructed
by looking into the fireplace.
2.
Check if the plug in the technical box is correctly
connected.See Wiring diagram on page 29.
3.
Check the connection with the ionisation pen and
whether there are damages to the ionisation cable.
4.
Measure the ionisation signal.
No flame is visible during ignition, but there was a spark
at the ignition pen.
1.
Remove the door from the fireplace (see 5.1.3 and 5.1.4)
2.
Carefully check if there no decorative elements are
obstructing the pen and if the spark correctly ignites
the burner.
3.
Ignite the gas fire without the door once and check if
gas is emanating from the burner. In case no gas ema-
nates from the burner: check for gas supply up to the
technical box (measure pre-pressure).
4.
In the presence of pre-pressure, check whether the
cables running from the automatic burner relay to the
gas valve unit are damaged and/or disconnected.
5.
In case of an excessive gas pressure level (>55mbar)
the gas valve cannot be opened for safety reasons.
The energy company or installer should fix this problem.
6.
In case of no result: exchange gas regulator.
No flame is visible during ignition and no spark is visible
at the ignition pen.
1.
Check whether the ignition pen is obstructed in
the fireplace.
2.
Check if the plug connection is correct inside the
technical unit. See Wiring diagram on page 29.
3.
Check whether there is sufcient power supply.
4.
Check the ignition cable for damages and check the
connection with the burner.
5.
Check/replace the HDIMS.
15A
Gas valve
problem
1.
Check the cover wiring.
2.
In case of correct wiring: exchange gas regulator.