Preparation 

 

The upcoming sections provide preparatory 

information prior to installation of the gas fire: 

 

Preliminary work with the help of a scale 

drawing 

 

Chimney calculation 

 

Check the gas fire  

 

Check UTP connection and/or WiFi signal 

 

 

4.1

 

Preliminary work with the help of 

a scale drawing 

You can use to your advantage a scale drawing 

prior to and during the placing of the 

concentric flue duct system and the gas fire. 

Scale drawings are available on the 

http://www.kalfire.com/en/ fireplaces website. 

Select the correct gas fire type here. Once you 

have made your choice, a page will open on 

which you will find “technical information

The subject 

documents

 with the scale 

drawing of the gas fire can be found there too. 

 

4.2

 

Chimney calculation 

Calculate the concentric flue duct system with 

the values of the chimney calculation or make a 

choice from the configurations in the 

appendices. See: flue duct configurations 1 

through 6, paragraph 8.1. 

 

A chimney calculation is made for the roof 

pass-through and the wall pass-through. The 

chimney calculation is suitable for gas types 

G20, G25, G30 and G31. Kalfire cannot 

guarantee proper operation of the fireplace if 

your configuration does not comply to the 

chimney calculation. 

 

 

CAREFUL!  

Many elbows and/or horizontally-mounted 

components of the flue duct can create 

substantial resistance. The flame pattern can 

vary considerably because the combustion air 

cannot easily reach the gas fire. 

 

 

Figure 3: Flue duct components

 

Table 1: Calculation values chimney calculation 

Components

 

Maximum permitted 

Kalfire Gi

 

First vertical metre 

 

Second metre and subsequent 

vertical metres 

11 meter 

metre horizontal pipe 

5 meter 

90° vertical elbow (A) 

3 units 

45° vertical elbow 

6 units 

90° horizontal elbow (B) 

2 units 

45° horizontal elbow 

4 units 

 

Example of chimney calculation 

Used parts 

Calculation Value 

1x 

1st vertical metre 

+9 

1x 

2nd vertical metre 

+1 

2x 

metre horizontal pipe 

-2 

2x 

90° vertical elbow (A) 

-4 

1x 

90° horizontal elbow (B) 

-4 

Result: 9 + 1 - 2 - 4 - 4 = 0. (This chimney calculation is not acceptable, it must be at least 0.5)

Summary of Contents for Gi75/59F

Page 1: ...INSTALLATION INSTRUCTIONS Balanced flue gas systems...

Page 2: ......

Page 3: ...Balanced flue gas system Kalfire Gi Gi75 59F Gi80 55C Gi85 55S Gi105 59F Gi110 55C Gi115 55S Gi105 79F Gi110 75C Gi115 75S For gastype G20 G25 G30 en G31 Version 12_2023...

Page 4: ...ng and testing the gas fire 19 5 5 Gas measurement 19 5 6 Sustainability measurement 19 5 7 Placing the restriction plates 20 5 8 Removing the ceiling plates 20 5 9 Placing and finishing the surround...

Page 5: ...of whatever nature can also affect the safety of the gas fire Alterations can nullify the warranty and the technical testing and certification is no longer applicable If the gas fire is not installed...

Page 6: ...ould the Kalfire approved installer be unable to rectify the problem covered by the warranty then he is entitled upon his own express desire to request Kalfire to assume responsibility for doing so on...

Page 7: ...ce Kalfire accepts no liability for the failure of the Gi fireplace to function properly or at all due to causes described here 1 5 Receipt and verification Verification upon receipt The gas fire is d...

Page 8: ...iance with the directives in force NEN 1078 and NPR 3378 apply to The Netherlands NBN D51 003 chimney connection and gas connection applies to Belgium Arbeitsblatt G600 DVGW TRGI applies to Germany Ch...

Page 9: ...fire and the fireproof board material The materials used for the gas fire surround must be heat resistant and fireproof Under no circumstances must the gas fireplace be insulated Materials plaster and...

Page 10: ...Especially the glass can get extremely hot Children and dependants are to stay clear of the burning gas fire DANGER Make sure that flammable materials such as curtains and furniture are at least 100...

Page 11: ...rrupted for one minute A new ignition attempt follows automatically To interrupt automatic ignition attempts immediately Press the on off button max 2 sec to switch the fire off immediately A 24 hour...

Page 12: ...es in the fireplace and burn slowly Heat emission The heat generated by Kalfire gas fireplaces is directly emitted to the space in which the fireplace is located through radiation and convection Radia...

Page 13: ...through 6 paragraph 8 1 A chimney calculation is made for the roof pass through and the wall pass through The chimney calculation is suitable for gas types G20 G25 G30 and G31 Kalfire cannot guarantee...

Page 14: ...if all moving parts of the gas fire are functioning correctly principally the door before installing the fireplace 4 4 Check UTP connection and or WiFi signal For correct and stable operation of the f...

Page 15: ...o flexible duct should be connected directly to the appliance The first metre from the appliance must always be carried out with a fixed pipe After the first metre the inner pipe flue may be made with...

Page 16: ...gas fire need to be precisely sawn off before they can be mounted When the bolts are mounted against the rear wall a space of a minimum of two cm is created between the rear side of the appliance and...

Page 17: ...nstallation Instructions paragraph 2 3 5 At the front leave a minimum of 1 mm of space between the glass support and the finishing Prevent excessive tension on the glass caused by the glass support as...

Page 18: ...ected app which can be downloaded from the Apple or Google app store TIP Check the strength of the wifi signal near the fireplace If necessary place a wifi amplifier near the fireplace to ensure a str...

Page 19: ...entification plate indicates which type of gas the appliance is set for The id plate is located on the left side of the cooling slot on a metal plate It can be tilted upwards see figure 16 To do this...

Page 20: ...late is supplied as standard with every fireplace Figure 18 Restriction plate assembly in the flue Carry out the following steps to place the restriction plate 1 Remove the door See Door dismantling a...

Page 21: ...necting with convection hood The convection hood is mounted on the appliance in the factory and so cannot be installed afterwards The convection hood ensures a delivery of controlled heat in the room...

Page 22: ...ording to the instructions It is prohibited to alter the number of decorative elements or the configuration thereof Such alterations can lead to hazardous situations with regard to fire safety Take th...

Page 23: ...airing takes place If automatic pairing does not take place proceed as follows You easily check whether the fireplace is paired by operating button 8 EmberGlow of the remote control see image below If...

Page 24: ...h consists of 5 levels The higher the level the more LEDs in the KalSense ring light up brightly In the KalfireConnected app the KalSense ring is also displayed on the screen This corresponds to the K...

Page 25: ...run mode the fireplace is on press button 1 x do not hold to switch off the fireplace The KalSense ring lights up briefly Comfort function Moves to the last used comfort plus setting KalSense feedback...

Page 26: ...han the remote control Besides controlling the various functions the temperature can be read and programmed for the thermostat and Comfort function via this app Furthermore 10 Moods can be programmed...

Page 27: ...g instructions anti reflective glass The gas fire glass can become dirty when the fireplace is burning but also when being taken into use Potential causes can be Smoking materials in the fireplace esp...

Page 28: ...the handles under the hood towards you and up Step 2 Push the metal cover strip in left or right Step 3 Next grip the door by the designated handles Slightly lift the door with glass window out of th...

Page 29: ...cover strip down 7 3 Replacing batteries If the red LED on the top right of the remote control no longer lights up if you press any of the buttons the battery needs to be replaced Replace the battery...

Page 30: ...tion 1 Gi105 59F Gi110 55C Gi115 55S Gi105 79F Gi110 75C Gi115 75S Gi105 59F Gi110 55C Gi115 55S Gi105 79F Gi110 75C Gi115 75S Gas type G20 G25 G30 G31 Flue duct diameter 130 200mm 1st metre vertical...

Page 31: ...5S Gi105 59F Gi110 55C Gi115 55S Gi105 79F Gi110 75C Gi115 75S Gas type G20 G25 G30 G31 Flue duct diameter 130 200 mm 1st metre vertical min 1 m 12 m 12 m 1st metre vertical min 1 m Vertical elbow 90...

Page 32: ...59F Gi110 55C Gi115 55S Gi105 79F Gi110 75C Gi115 75S Gas type G20 G25 G30 G31 Flue duct diameter 130 200 mm Max vertical length m 12 m 12 m 1st metre vertical min 1 m Vertical elbow 90 Remove the ce...

Page 33: ...9F Gi110 55C Gi115 55S Gi105 79F Gi110 75C Gi115 75S Gas type G20 G25 G30 G31 Flue duct diameter 130 200 mm Max vertical length m 12 m 12 m 1st metre vertical min 1 m Vertical elbow 90 Horizontal sect...

Page 34: ...S Gi105 79F Gi110 75C Gi115 75S Gas type G20 G25 G30 G31 Flue duct diameter 130 200 mm Max vertical length m 12 m 12 m 1st metre vertical min 1 m Vertical elbow 90 Remove the ceiling plate 3 3 Vertica...

Page 35: ...0 55C Gi115 55S Gi105 79F Gi110 75C Gi115 75S Gas type G20 G25 G30 G31 Flue duct diameter 130 200 mm Max vertical length m 12 m 12 m 1e meter verticaal min 0 5m Vertical elbow 90 Horizontal section ma...

Page 36: ...110 75C Gi115 75S Gi105 59F Gi110 55C Gi115 55S Gi105 79F Gi110 75C Gi115 75S Gas type G20 G25 G30 G31 Flue duct diameter 130 200 mm Max vertical length m 12 m 12 m Elbow 15 30 of 45 Diagonal section...

Page 37: ...5S Gi105 59F Gi110 55C Gi115 55S Gi105 79F Gi110 75C Gi115 75S Gas type G20 G25 G30 G31 Flue duct diameter 130 200 mm Max vertical length m 12 m 12 m Elbow 15 30 of 45 Diagonal section Elbow 15 30 of...

Page 38: ...75S Gi105 59F Gi110 55C Gi115 55S Gi105 79F Gi110 75C Gi115 75S Gas type G20 G25 G30 G31 Flue duct diameter 130 200 mm Max vertical length m 12 m 12 m Connector 130 200 100 150 C Elbow 15 30 of 45 Dia...

Page 39: ...30 G31 Flue duct diameter 130 200 mm Max vertical length m 12 m 12 m Situation 1 Connector 130 200 100 150 C n a n a Min 1 m Max 2 m vertical 130 200 Roof pass through B Situation 2 Min 2 m Max 4 m ve...

Page 40: ...sure sensor hotel switch Safety Contact 5 6 The Gi checks the status of this input it must be closed before the start of the ignition cycle and during the operational status of the Gi If it is opened...

Page 41: ...77 1 79 1 71 7 G30 50mbar C 7 3 1 8 77 1 79 1 71 7 G31 37 mbar D 6 1 1 5 73 5 75 9 65 4 Kalfire Gi105 59F Kalfire Gi105 79F Kalfire Gi110 55C Kalfire Gi110 75C Kalfire Gi115 55S Kalfire Gi115 75S G25...

Page 42: ...82 77 1 G31 37 mbar C 6 4 1 6 79 81 2 70 5 Kalfire Gi105 59F Kalfire Gi105 79F Kalfire Gi110 55C Kalfire Gi110 75C Kalfire Gi115 55S Kalfire Gi115 75S G25 3 B 7 4 2 2 86 6 88 5 84 5 G20 B 7 5 2 4 86 8...

Page 43: ...e detection no room temperature control with open window detection no with distance control option yes with adaptive start control no with working time limitation no with black bulb sensor no Indirect...

Page 44: ...uations with regard to fire safety Take the instructions into account Safety instructions for decorative elements paragraph 2 4 Artikel nr Artikel omschrijving Aantal 1 550057 Cover log F060683 1 2 55...

Page 45: ...45...

Page 46: ...46...

Page 47: ...47...

Page 48: ...nstructions into account Safety instructions for decorative elements paragraph 2 4 Article nr Article description Number 1 550129 Burner cover Gi KF03661 1 2 550132 Deco plate back Gi KF03655 1 3 5501...

Page 49: ...49...

Page 50: ...50...

Page 51: ...51...

Page 52: ...52...

Page 53: ...53...

Page 54: ...54...

Page 55: ...I3B P G30 28 30 9 2 0 28 2x 1 0 1 4 11 3 4 1 7 3 79 1 C C 73 I3B P G30 50 9 2 0 28 2x 1 0 1 4 11 3 4 1 7 3 79 1 C C 73 KALFIRE Gi105 59F Gi110 55C Gi115 55S Gas cat Gas type Connection pressure Load...

Page 56: ...K G25 3 25 8 5 1 02 2x 1 6 1 8 19 4 7 1 6 8 81 1 C B 69 I2ELL G20 G25 20 8 7 0 92 2x 1 6 1 8 15 5 6 5 6 9 79 7 C B 83 I3 G31 37 7 1 0 29 2x 1 0 1 4 14 7 4 2 5 6 78 6 C B 65 I3 G30 28 30 9 1 0 28 2x 1...

Page 57: ...G30 28 30 mbar I3B P G30 50 mbar LB LT LU LV MT NL NO NZ PL PT RO RU SE SI SK TN UA I2H G20 20 mbar I2E G20 20 mbar I2E G20 G25 20 25 mbar I2 43 46 45 3 MJ m3 0 C I2K G25 3 25 mbar I2ELL G20 G25 20 m...

Page 58: ...F Gi110 75C Gi115 75S This declaration of conformity complies with the Harmonisation legislation of the Union Directive 2009 142 EC Regulation EU 2016 426 of 21 April 2018 Directive 2009 125 EC Regula...

Page 59: ...59...

Page 60: ...Gelo rveldweg 21 5951 DH Belfeld info kalfire com KALFIRE COM V12 2023 EN...

Reviews: