2-2
System Components
The degree of protection provided by the ProLine 2200 system is IP21S and as such is intended
only for indoor use. It is not suitable for use in rain or snow.
The Proline 2200 system is tested in accordance with CISPR 11, EMC classification – Group 2
ISM (Class A).
The ProLine 2200 consists of the following components:
Standard Components
•
Power Supply
•
Gas Console
•
Remote High Frequency (RHF) Console
•
RHF Console Control Cable
•
Torch and Handle Assembly
•
Torch Lead Set
•
Torch Solenoid Valve Assembly
•
Torch Solenoid Valve Control Cable
•
Water and Power Leads
•
Gas Hose Package
•
Work Ground Lead
•
System Manual
•
Consumable Spare Parts Kit (see Section 6 for details)
Optional Components
•
Remote On/Off Control Assembly
•
Hydrogen Manifold Assembly
Power Supply Specifications
Stock Number:
208 VAC, 3Ø, 60Hz .............................................277411
230/460 VAC, 3Ø, 60Hz ..................................... 277412
380 VAC, 3Ø, 50/60Hz ....................................... 277415
415 VAC, 3Ø, 50/60Hz ....................................... 277414
575 VAC, 3Ø, 60Hz .............................................277413
Input Current at Maximum Output:
208 VAC, 3Ø, 60Hz .............................................115 amps
230/460 VAC, 3Ø, 60Hz ..................................... 104/52 amps
380 VAC, 3Ø, 50/60Hz ....................................... 63 amps
415 VAC, 3Ø, 50/60Hz ....................................... 58 amps
575 VAC, 3Ø, 60Hz .............................................42 amps