Operation
ProLine 2200 User’s Manual REV N
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
4-18
Stainless Steel - 70 Amps – Air Plasma / Nitrogen Shield
Copper Electrode
This gas combination gives medium cut quality and minimum dross levels
Shield Cap
Nozzle
Electrode
277150
277125
277131
Outer Cap
Retaining Cap
Swirl Ring
Torch Head
277154
277153
277142
279150
Imperial
Material
Thickness
Preflow
Air
Plasma
Air
Shield
Nitrogen
Postflow
Air
Arc
Voltage
Travel
Speed
Cutting
Height
Pierce
Height
Pierce
Time
Kerf
Width
(ga)
(in)
(psi)
(psi)
(psi)
(psi)
(volts)
(ipm)
(in)
(in)
(msec)
(in)
10
.135
25
80
25
2
132
120
.060
.150
200
.085
3/16
134
100
.070
.200
300
1/4
140
75
.090
.225
400
.090
3/8
148
50
.120
.250
500
Metric
Material
Thickness
Preflow
Air
Plasma
Air
Shield
Nitrogen
Postflow
Air
Arc
Voltage
Travel
Speed
Cutting
Height
Pierce
Height
Pierce
Time
Kerf
Width
(mm)
(psi)
(psi)
(psi)
(psi)
(volts)
(mm/m)
(mm)
(mm)
(msec)
(mm)
3
25
80
25
2
131
3210
1.4
3.3
200
2.2
5
134
2445
1.8
5.1
400
6
138
2050
2.1
5.5
2.3
* Use an arc transfer height (ignition height) of .150” (3.3 mm)
1. Revised on 01/18/2011