Operation
ProLine 2200 User’s Manual REV N
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
4-28
Aluminum - 100 Amps – Air Plasma / Nitrogen Shield
Copper Electrode
Shield Cap
Nozzle
Electrode
277286
277284
277282
Outer Cap
Retaining Cap
Swirl Ring
Torch Head
277154
277151
277283
279150
Imperial
Material
Thickness
Preflow
Air
Plasma
Air
Shield
Nitrogen
Postflow
Air
Arc
Voltage
Travel
Speed
Cutting
Height
Pierce
Height
Pierce
Time
Kerf
Width
(in)
(psi)
(psi)
(psi)
(psi)
(volts)
(ipm)
(in)
(in)
(msec)
(in)
1/4
25
94
26
0
158
105
.155
.250
300
.095
3/8
162
90
.180
.275
400
.098
1/2
165
70
.195
.300
500
.100
Metric
Material
Thickness
Preflow
Air
Plasma
Air
Shield
Nitrogen
Postflow
Air
Arc
Voltage
Travel
Speed
Cutting
Height
Pierce
Height
Pierce
Time
Kerf
Width
(mm)
(psi)
(psi)
(psi)
(psi)
(volts)
(mm/m)
(mm)
(mm)
(msec)
(mm)
6
25
94
26
0
158
2710
3.8
6.3
300
2.4
10
162
2210
4.6
7.0
500
2.5
12
165
1890
4.9
7.4
* Use an arc transfer height (ignition height) of .250” (6.3 mm)
1. Revised on 01/18/2011