Installation
Spirit200a User’s Manual Rev J
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
3-5
Power Supply Output Connections
Perform the following steps to connect the output of the power supply to
the RHF console and the work table. See figure below.
Power Supply Electrode Lead
1. Route one end of the #1/0AWG power supply electrode lead through
the upper strain relief on the rear of the power supply and connect it to
the electrode terminal.
2. Route the other end of the power supply electrode lead through the
strain relief on the RHF console and connect it to the cathode manifold.
Power Supply Nozzle Lead
1. Route one end of the #10AWG power supply nozzle lead through the
upper strain relief on the rear of the power supply and connect it to the
nozzle terminal.
2. Route the other end of the power supply nozzle Lead through the
strain relief on the RHF console and connect it to the pilot terminal on
the RHF console printed circuit board.
Power Supply CTP Sensor Lead
1. Route the end of the #14AWG power supply CTP sensor lead with the
ring terminal through the middle strain relief on the rear of the power
supply and connect it to the CTP terminal.
2. Route the end of the power supply CTP sensor lead with the fast-on
terminal through the strain relief on the RHF console and connect it to
the CTP sensor lead filter assembly.
RHF Console Control Cable
1. Connect the RHF console control cable plug labeled P16 to the
connector labeled P16 on the rear of the power supply.
2. Connect the RHF console control cable plug labeled P1 to the
connector labeled P1 on the RHF console.
Power Supply Coolant Supply Hose
1. Connect one end of the power supply coolant supply hose to the
coolant supply fitting on the rear of the power supply. Note that the
coolant supply fitting has right hand threads.
2. Connect the other end of the power supply coolant supply hose to the
coolant in fitting on the RHF console. Note that the coolant in fitting
has right hand threads.
1
2
3
4
5