Maintenance and Troubleshooting SR-45i User’s Manual
5.
Reassemble the electrode, swirl ring, and nozzle and install them in the torch.
6.
Make sure that the retaining cap is hand tight and all parts are seated properly.
Monthly Procedures
Note: At minimum, these checks should be performed on a monthly basis.
In excessively dirty environments or in heavy usage situations, the checks
should be performed more frequently.
** WARNING **
Remove primary power from the system before performing the following
procedures
SR-45i Power Supply
1.
Remove the rear panel of the power supply.
2.
Verify that all torch lead connections and work ground connections are secure.
Only tighten the gas fittings enough to make a gas seal. The fittings are
subject to damage if over tightened
.
3.
Verify that the primary AC connections are tight.
4.
Remove the left and right side panels and blow out the power supply cabinet
with clean, dry, compressed air. Be sure to blow off all circuit bards.
5.
Verify that all p.c. board connectors are installed securely.
6.
Verify that the rear panel Amp connectors are installed securely.
7.
Check the pilot arc relay contacts for signs of pitting and replace if necessary.
8.
Verify that all hardware connections are tight.
9.
Clean and reset the spark gap spacing to .015” (.38 mm).
10.
Check the connection of the high frequency coupling transformer leads to the
I/O p.c. board.
11.
Verify that the fan blades spin freely.
SR-45i Torch Leads
1.
Verify that all torch lead connections are secure.
Only tighten the gas
fittings enough to make a gas seal. The fittings are subject to damaged if
over tightened.
2.
Remove the retaining cap and consumables from the torch.
3.
Using an ohmmeter, measure zero ohms between the power supply Torch
Minus connector on the I/O p.c. board and the cathode body inside the torch.
The cathode body is the brass piece that the electrode seats against.
4.
Using an ohmmeter, measure zero ohms between the power supply Pilot Arc
connector on the I/O p.c. board and the torch anode body. The anode body is
the brass piece that the retaining cap threads onto.
5.
Verify that the braided shield of the torch leads is secured to the brass adaptor
that connects to the power supply. Also, make sure the adaptor is secured
5-2
Summary of Contents for SR-45i
Page 2: ...This page intentionally left blank ...
Page 8: ...This page intentionally left blank ...
Page 20: ...This page intentionally left blank ...
Page 38: ...This page intentionally left blank ...
Page 52: ...This page intentionally left blank ...
Page 55: ...Parts List SR 45i User s Manual Figure 6 1 Control Panel 6 3 ...
Page 56: ...Parts List SR 45i User s Manual SR 45i Figure 6 2 Rear View Inside 6 4 ...
Page 57: ...Parts List SR 45i User s Manual Figure 6 3 Base Top View 6 5 ...
Page 58: ...Parts List SR 45i User s Manual Figure 6 4 Left Side View 6 6 ...
Page 59: ...Parts List SR 45i User s Manual Figure 6 5 Right Side View 6 7 ...
Page 60: ...Parts List SR 45i User s Manual SR 45i Figure 6 6 Rear View Outside 6 8 ...
Page 65: ...Parts List SR 45i User s Manual Chopper P C Board Figure 6 10 Chopper P C Board 6 13 ...