Maintenance and Troubleshooting SR-45i User’s Manual
chopper. If the lines are good and no lines are shorted together, replace
the chopper (skip the rest of this test).
c. Give the system a start command. When the red D.C. Power light
illuminates, the voltage on P1-2 should drop to approximately 0 VDC. If
P1-2 does not read 0 VDC, check the continuity in the lines between the
chopper and the logic board. Next, verify that the REG LED is
illuminated on the logic-regulator p.c. board. If the REG LED is
illuminated, the lines between the chopper and the logic-regulator are
good, but the voltage on P1-2 does not drop to 0 VDC, replace the logic-
regulator p.c. board.
d. If P1-2 measured 0 VDC in step c above but there is still no voltage
between Torch Minus and Work Ground on the I/O p.c. board, replace
the chopper.
5-13
Summary of Contents for SR-45i
Page 2: ...This page intentionally left blank ...
Page 8: ...This page intentionally left blank ...
Page 20: ...This page intentionally left blank ...
Page 38: ...This page intentionally left blank ...
Page 52: ...This page intentionally left blank ...
Page 55: ...Parts List SR 45i User s Manual Figure 6 1 Control Panel 6 3 ...
Page 56: ...Parts List SR 45i User s Manual SR 45i Figure 6 2 Rear View Inside 6 4 ...
Page 57: ...Parts List SR 45i User s Manual Figure 6 3 Base Top View 6 5 ...
Page 58: ...Parts List SR 45i User s Manual Figure 6 4 Left Side View 6 6 ...
Page 59: ...Parts List SR 45i User s Manual Figure 6 5 Right Side View 6 7 ...
Page 60: ...Parts List SR 45i User s Manual SR 45i Figure 6 6 Rear View Outside 6 8 ...
Page 65: ...Parts List SR 45i User s Manual Chopper P C Board Figure 6 10 Chopper P C Board 6 13 ...