http://www.nexbill.co.kr
VID 1301 SPEED CALIBRATION
▶ Content
To calibrate the speed
Speed 1 = 850, speed 2 = 1000, speed 3 = 1250, speed 4 = 1500, speed 5 = 1850
PWM up = “1”key, PWM down = “7”key
▶ Operation Procedure
1
3
0
1
Press “Enter ”key while the display indicates “1301”
↓
S
P
3
1
2
5
0
The display indicates standard count per minute at
speed 3
↓
4
5
1
1
5
0
Upper: The display indicates number of count “45”
Down: Real speed at speed 3.
It is 1150note/min at speed 3.
↓
7
8
Please increase PWM more with pressing “1” button.
Count again and set the speed as close as standard
speed(1250/min)
↓
S
P
4
1
5
0
0
Press “5”key. The display indicates standard count per
minute at speed 4.
Please count sample notes and set the speed with “1”
or “7” button.
↓
S
P
5
1
8
5
0
Press “5”key. The display indicates standard count per
minute by speed 5.
Please count sample note and set the speed at
1750/min to make more durability.
↓
S
P
1
8
5
0
Press “5”key. The display indicates standard count per
minute by speed 1
↓
S
P
2
1
0
0
0
Press “5”key. The display indicates standard count per
minute by speed 2
↓