30
P67
TIME SETTING FOR SENDING INFORMATION USING THE
BOXNET FUNCTION. TIME IS GIVEN IN FOLLOWING
FORMAT: HH.MM.SS, FOR EXAMPLE 05.25.00 MEANS DATA
FROM MACHINE WILL BE SENT EACH 5 HOURS 25 MINUTES.
P67 = 0;
FUNCTION IS OFF, NO DATA IS SENT,
P67 = 00.00.05...00.01.00;
CYCLE BETWEEN SENDING INFO
PACKETS IS 5 SEC TO 1 MIN (IN 5 SEC JUMPS),
P67 = 00.05.00...18.00.00;
CYCLE BETWEEN SENDING INFO
PACKETS IS 5 MIN TO 18 HOURS (IN 5 MIN JUMPS).
WHEN TURNING THE MACHINE ON, THE DATA IS SENT
AFTER FIRST 3 MINUTES, DESPITE P67’S SETTING, IN ORDER
TO STABILIZE GSM CONNECTION (ALTHOUGH NO DATA IS
SENT WHEN P67=0).
AFTER SETTING TIME IN P67 MACHINE HAS TO BE TURNED
OFF AND TURNED BACK ON.
P68
SETTING FOR FLASHING LIGHTS IN IDLE STATE:
P68 = 0;
OFF,
P68 = 1 TO 60;
MINUTES BEFORE LIGHTS START
FLASHING. DEFAULT SETTING: 0.
P69
SETTING FOR SOUND DELAY IN IDLE STATE:
P69 = 0;
OFF,
P69 = 1 TO 60;
MINUTES BEFORE SOUND STARTS
PLAYING. DEFAULT SETTING: 0.
NOTE: dip switch #3 will determine if sound will be played.
P70
AUTOPLAY –SETTING TIME AFTER WHICH MACHINE WILL
RELEASE A FREE GAME.
P70 = 0;
OFF,
P70 = 1 TO 180;
MINUTES BEFORE FREE GAME IS
ACTIVATED. DEFAULT SETTING: 0.
P71
PRINT PRIZE #1 (
1 = PRINT, 0 = DON’T PRINT
). DEFAULT
SETTING : 0. WORKS FOR P23=0 OR P23=3.
P72
PRINT PRIZE #2 (
1 = PRINT, 0 = DON’T PRINT
). DEFAULT
SETTING : 0. WORKS FOR P23=0 OR P23=3.
Summary of Contents for Comboboxer
Page 1: ...COMBOBOXER Punch Force measuring machine Technical Information...
Page 17: ...17 10 Machine setup Main Board Layout Back Side Drawing 1...
Page 37: ...37 Main Board Layout Front Drawing 2 Drawing 3...
Page 38: ...38 Boxer Power Supply Layout Drawing 4 Kicker Power Supply Layout Drawing 5...
Page 40: ...40 Sensor 1 Emitter 2 Cathode 3 Anode 4 Collector Drawing 8...
Page 62: ...62 MAIN BOARD SETTINGS P91 P92 P93 P94 P95 P96...