background image

 

 

 

Captis Cloud Configuration Guide  

 

Page | 3  

2.2  Compatibility  

It is important to ensure that the sensor being terminated is compatible with the 
selected Captis device. Please find compatibility details below noting that all approved 
sensors

2

 may be connected and logged at once. However, any more than 2 x digital 

inputs may adversely affect battery longevity.  

DEVICE  

SENSOR INPUTS 

Pulse 1.2 and Pulse Lite 1.0 

 2 x Digital Inputs  

Multi 1.2 and Recharge 1.2 

 2 x Digital Inputs 

 1 x 4-20mA Analogue Input  

 1 x 0-10VDC Analogue Input  

 1 x Serial Input (Modbus RS232/RS485) 

 1 x 1-Wire Input 

Table 2 

3  Terminating  

When terminating cable into the Captis

’ Amphenol connector please follow these steps: 

1.  Prepare the cable  

2.  Crimp the pins 

3.  Secure the pins  

4.  Fasten the connector 

3.1  Prepare the Cable 

The following diagrams outline how to prepare the sensor cable for termination. These 
guidelines support the manufacturers specification. 

 

 

 

 

 

Table 3 

Strip Insulation Length (A) 

Strip Jack Length (B) 

3.5mm 

– 4mm 

16mm 

– 18mm 

 

 

2

 Please contac

support@kallipr.com

 to ensure the selected sensor is compatible with the selected Captis device. 

Reviews: