HOMEOWNERS GUIDE
Bath with Airjets
1096755-5-
D
10 of 16
Questions? Problems? For additional assistance, please contact KALLISTA’s Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.
Symptoms
Probable Causes
Recommended Action
2. Ground-Fault Circuit-Interrupter
(GFCI) or Residual Current
Device (RCD) trips when bath
with airjets is turned on.
A. Electrical harness is wet or
damaged.
A. Check for wet connections.
Dry the connections and repair
the leak. Check for insulation
or connector damage. Replace
the harness if damaged. Refer
to your installer or wholesale
dealer.
B. Electrical wiring to the bath
junction box is wet or damaged.
B. Have a quali
fi
ed electrician
diagnose and correct the
problem in accordance with
applicable building and electrical
codes.
C. Electrical wiring to the bath
power cord is wet or damaged.
C. Have a quali
fi
ed electrician
diagnose and correct the
problem in accordance with
applicable building and electrical
codes.
D. Blower motor is shorted
internally.
D. Replace the blower motor. Refer
to your installer or wholesale
dealer.
E. Control is shorted internally.
E. Replace the control. Refer
to your installer or wholesale
dealer.
3. User keypad is illuminated, but
does not respond to buttons or
outer ring.
A. Control program is locked.
A. Reset GFCI or RCD.
B. P5 plug assembly harness from
user keypad to control is loose,
disconnected, or damaged.
B. Check wiring for proper
connections. Replace the wiring
harness if necessary. Refer
to your installer or wholesale
dealer.
C. User keypad does not work.
C. Replace the user keypad. Refer
to your installer or wholesale
dealer.
D. Control does not work.
D. Replace the control. Refer
to your installer or wholesale
dealer.