HOMEOWNERS GUIDE
Bath with Airjets
1096755-5-
D
11 of 16
Questions? Problems? For additional assistance, please contact KALLISTA’s Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.
Symptoms
Probable Causes
Recommended Action
4. Blower motor will not start.
A. Power cord from blower motor
to control is loose, disconnected,
or damaged.
A. Check wiring for proper
connections.
B. Blower motor does not work.
B. Replace the blower motor. Refer
to your installer or wholesale
dealer.
C. Control does not work.
C. Replace the control. Refer
to your installer or wholesale
dealer.
5. Blower motor stops running
and will not immediately restart.
Keypad is illuminated.
A. Blower motor overheated and
protection device activated.
A. Check for blockage at motor
vents. Remove blockage and
allow motor to cool. Refer to
dealer or wholesale distributor.
Otherwise, refer to “User keypad
is illuminated, but does not
respond to buttons or outer ring.
Blower motor will not start.”
6. Blower motor starts, some but
not all airjets are bubbling.
A. Blower motor speed is too low.
A. Increase speed setpoint to
blower motor.
B. Blower motor inlet is blocked.
B. Clean blower motor inlet.
C. Blower motor does not work.
C. Replace the blower motor. Refer
to your installer or wholesale
dealer.
D. Blower motor discharge is
blocked.
D. Check blockage.
E. Check valve does not work.
E. Replace the check valve. Refer
to your installer or wholesale
dealer.
F. Air jets are clogged.
F. Use a small between-the-teeth
dental brush and white vinegar.
Dip the brush in the vinegar,
brush the hole, rinse the brush
in clean water, and then use the
wet rinsed brush to rinse the
hole.