USER KEYPAD AND BATH WITH AIRJETS MODES/FEATURES

Rotating Ring Key Pad

Purge Mode

Decrease Flow or Surge

Indicator Bar

Increase Flow or Surge

Surge Mode

Zone 3

Power On/Off

Zone 1

Air Flow Mode

Activates Mode Selected

Zone 2

Rotate outer ring to
access desired mode.

 

Power On/Off -

 Turns the blower motor on and off. Symbols illuminated in blue indicate available modes/

features. Modes which are operating will display in green.

 

Activate Button -

 Press “OK” to activate the desired mode. The active mode will 

fl

 ash (green).

 

Up Arrow -

 Increases the air 

fl

 ow when the air 

fl

 ow mode is active. Increases the pulse speed when the 

surge mode is active.

 

Down Arrow -

 Decreases the air 

fl

 ow when the air 

fl

 ow mode is active. Decreases the pulse speed when 

the surge mode is active.

 

Outer Ring -

 Rotate the outer ring to the desired mode. The selected mode will 

fl

 ash (blue).

 

Indicator Bar -

 Shows the air 

fl

 ow volume when operating in the air 

fl

 ow mode. Shows the surge speed 

when operating in the surge mode.

 

Purge Mode -

 Select to initiate the purge mode manually. The purge cycle will not start if there is water in 

the bath. The purge mode blows any residual water out of the air channels. The blower motor starts and 
runs at a low speed for about two minutes. An automatic purge cycle occurs when the bath is drained and 
the water level falls below the level sensors.

 

Air Flow Mode -

 In this mode, air 

fl

 ow is directed through any combination of the airjets in the selected 

zones. Air 

fl

 ow can be adjusted with the arrow buttons. When the surge mode is selected, the air 

fl

 ow mode 

stops. When the air 

fl

 ow mode is selected while operating in the surge mode, the surge mode stops.

 

Zone 1 -

 This mode is used to select or deselect the air 

fl

 ow through Zone 1.

 

Zone 2 -

 This mode is used to select or deselect the air 

fl

 ow through Zone 2.

 

Zone 3 -

 This mode is used to select or deselect the air 

fl

 ow through Zone 3.

 

Surge Mode -

 When active, the air 

fl

 ow ramps up from minimum to maximum and then down again to 

minimum. The surge speed is adjustable between 10 seconds to 60 seconds by using the up or down 
buttons. The up and down arrow buttons can be used to adjust the surge speed. Zones can be selected or 
deselected when in the surge mode.

Summary of Contents for P50045-G5

Page 1: ...ts 1096755 5 D 1 of 16 Questions Problems For additional assistance please contact KALLISTA s Customer Service Department at 1 888 4 KALLISTA 1 888 452 5547 or FAX 1 888 272 3094 P50045 G5 P50047 G5 P...

Page 2: ...the body dizziness lethargy drowsiness and fainting The effects of hyperthermia include a failure to perceive heat b failure to recognize the need to exit the bath c unawareness of impending hazard d...

Page 3: ...ve the problem corrected by a qualified service representative before using Your new KALLISTA bath has been listed by Underwriter s Laboratories ensuring safety for you and your family This bath also...

Page 4: ...s you to access the airjet modes and adjust the airflow Airjets Holes through which the air flows Level Sensor Determines when the bath has been drained and starts the timing for the automatic purge c...

Page 5: ...en operating in the air flow mode Shows the surge speed when operating in the surge mode Purge Mode Select to initiate the purge mode manually The purge cycle will not start if there is water in the b...

Page 6: ...ase Flow or Surge Surge Mode Zone 3 Power On Off Zone 1 Air Flow Mode Activates Mode Selected Zone 2 Rotate outer ring to access desired mode Starting the Unit If the unit does not function properly p...

Page 7: ...ashing blue Press the OK button once The purge icon flashes green and the mode is implemented The air system operates at a low speed to blow any residual water out of the air channels After about 2 mi...

Page 8: ...kmanship for five years from the date of installation Kallista will at its election repair replace or make appropriate adjustment where Kallista inspection discloses any such defects occurring in norm...

Page 9: ...oubleshooting the Bath with Airjets System Symptoms Probable Causes Recommended Action 1 User keypad does not illuminate when power button is pressed or the outer ring is rotated A No power to control...

Page 10: ...ble building and electrical codes C Electrical wiring to the bath power cord is wet or damaged C Have a qualified electrician diagnose and correct the problem in accordance with applicable building an...

Page 11: ...n device activated A Check for blockage at motor vents Remove blockage and allow motor to cool Refer to dealer or wholesale distributor Otherwise refer to User keypad is illuminated but does not respo...

Page 12: ...r installer or wholesale dealer D Blower motor does not work D Replace the blower motor Refer to your installer or wholesale dealer E Control does not work E Replace the control Refer to your installe...

Page 13: ...wholesale dealer 10 A zone does not produce air bubbles but another zone operates normally A Zone is not selected A Select the zone per the instructions in the Confirm Proper Operation section B Butt...

Page 14: ...8 272 3094 Symptoms Probable Causes Recommended Action 12 Water spillage or damage observed under the bath A Drain or overflow leaking A Repair or replace the drain assembly per the manufacturer s ins...

Page 15: ...tomer Service Department at 1 888 4 KALLISTA 1 888 452 5547 or FAX 1 888 272 3094 SERVICE PARTS 1 1 4 Tubing 1096498 Butterfly 95045 Screw 1038690 Vent Assembly 1 1 2 Tubing 1 1 2 Tubing 95045 Screw 1...

Page 16: ...ire Assembly 61845 K Grounding Wire 1019447 B Isolation Mount 1032645 Control 1032583 Board 1036872 Control Kit 1035939 Screw 50506 Screw 96956 Butterfly 1016466 Motor 63149 Screw Butterfly Valve 9389...

Reviews: