background image

HOMEOWNERS GUIDE

  Bath with Airjets

1096755-5-

D

8 of 16

Questions? Problems? For additional assistance, please contact KALLISTA’s Customer

Service Department at 1-888-4-KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.

CARE AND CLEANING INSTRUCTIONS (CONT’D.)

Maintaining the Airjets

 

If cleaning the airjets is required due to hard water deposits, use a small between-the-teeth dental brush 
and white vinegar. Dip the brush in the vinegar, brush the hole, rinse the brush in clean water, and then use 
the wet rinsed brush to rinse the hole.

 

Fill the bath with water to the top row of airjets. Drain the bath and press the purge button.

Flushing your Airbath System

 

Flush your whirlpool system twice a month or more, depending upon usage.

 

Fill bath with water one inch above the top of all airjets.

 

While bath is 

fi

 lling, carefully add one cup of bleach to the water.

 

Let sit for 10-15 minutes.

 

Drain the water, run the purge cycle and rinse any debris from the bath.

 

Clean bath surfaces as needed with recommended cleaners. 

 

Dry the bath with a clean, soft towel.

FIVE-YEAR LIMITED WARRANTY

All Kallista products carry Kallista’s 

fi

 ve-year warranty unless otherwise noted.*

Kallista’s products are warranted to be free of defects in material and workmanship for 

fi

 ve years from the date 

of installation.
Kallista will, at its election, repair, replace, or make appropriate adjustment where Kallista inspection discloses 
any such defects occurring in normal usage within 

fi

 ve (5) years after installation. Kallista is not responsible 

for removal or installation costs. Damages due to improper handling, installation or maintenance are not 
considered manufacturing defects and are not covered by this warranty. This warranty is valid for the original 
consumer purchaser only. Use of in-tank toilet cleaners will void the warranty.
To obtain warranty service, contact you Kallista Authorized Showroom.

IMPLIED WARRANTIES INCLUDING THAT OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR 
PURPOSE ARE EXPRESSLY LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. KALLISTA 
AND/OR SELLER DISCLAIMS ANY LIABILITY FOR SPECIAL, INCIDENTAL, OR CONSEQUENTIAL 
DAMAGES.

Some states/provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or 
limitation of special, incidental or consequential damages, so these limitations and exclusions may not apply to 
you. This warranty gives you speci

fi

 c legal rights. You may also have other rights which vary from state/province 

to state/province.

This is Kallista’s exclusive written warranty.

* Kallista’s Hampstead and Stafford vitreous products, stainless steel accessories, and wooden accessories 
carry a one-year Limited Warranty.

Summary of Contents for P50045-G5

Page 1: ...ts 1096755 5 D 1 of 16 Questions Problems For additional assistance please contact KALLISTA s Customer Service Department at 1 888 4 KALLISTA 1 888 452 5547 or FAX 1 888 272 3094 P50045 G5 P50047 G5 P...

Page 2: ...the body dizziness lethargy drowsiness and fainting The effects of hyperthermia include a failure to perceive heat b failure to recognize the need to exit the bath c unawareness of impending hazard d...

Page 3: ...ve the problem corrected by a qualified service representative before using Your new KALLISTA bath has been listed by Underwriter s Laboratories ensuring safety for you and your family This bath also...

Page 4: ...s you to access the airjet modes and adjust the airflow Airjets Holes through which the air flows Level Sensor Determines when the bath has been drained and starts the timing for the automatic purge c...

Page 5: ...en operating in the air flow mode Shows the surge speed when operating in the surge mode Purge Mode Select to initiate the purge mode manually The purge cycle will not start if there is water in the b...

Page 6: ...ase Flow or Surge Surge Mode Zone 3 Power On Off Zone 1 Air Flow Mode Activates Mode Selected Zone 2 Rotate outer ring to access desired mode Starting the Unit If the unit does not function properly p...

Page 7: ...ashing blue Press the OK button once The purge icon flashes green and the mode is implemented The air system operates at a low speed to blow any residual water out of the air channels After about 2 mi...

Page 8: ...kmanship for five years from the date of installation Kallista will at its election repair replace or make appropriate adjustment where Kallista inspection discloses any such defects occurring in norm...

Page 9: ...oubleshooting the Bath with Airjets System Symptoms Probable Causes Recommended Action 1 User keypad does not illuminate when power button is pressed or the outer ring is rotated A No power to control...

Page 10: ...ble building and electrical codes C Electrical wiring to the bath power cord is wet or damaged C Have a qualified electrician diagnose and correct the problem in accordance with applicable building an...

Page 11: ...n device activated A Check for blockage at motor vents Remove blockage and allow motor to cool Refer to dealer or wholesale distributor Otherwise refer to User keypad is illuminated but does not respo...

Page 12: ...r installer or wholesale dealer D Blower motor does not work D Replace the blower motor Refer to your installer or wholesale dealer E Control does not work E Replace the control Refer to your installe...

Page 13: ...wholesale dealer 10 A zone does not produce air bubbles but another zone operates normally A Zone is not selected A Select the zone per the instructions in the Confirm Proper Operation section B Butt...

Page 14: ...8 272 3094 Symptoms Probable Causes Recommended Action 12 Water spillage or damage observed under the bath A Drain or overflow leaking A Repair or replace the drain assembly per the manufacturer s ins...

Page 15: ...tomer Service Department at 1 888 4 KALLISTA 1 888 452 5547 or FAX 1 888 272 3094 SERVICE PARTS 1 1 4 Tubing 1096498 Butterfly 95045 Screw 1038690 Vent Assembly 1 1 2 Tubing 1 1 2 Tubing 95045 Screw 1...

Page 16: ...ire Assembly 61845 K Grounding Wire 1019447 B Isolation Mount 1032645 Control 1032583 Board 1036872 Control Kit 1035939 Screw 50506 Screw 96956 Butterfly 1016466 Motor 63149 Screw Butterfly Valve 9389...

Reviews: