INSTALLATION INSTRUCTIONS
60" x 32" Acrylic Air Bath
1107630-2-
C
12 of 28
Questions? Problems? For additional assistance, please contact KALLISTA’s Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or kallista.com.
6. MAKE POWER CONNECTIONS - STANDARD
Neutral
Bus
N
L1
L2
120 V
120 V
240 V
S/N
*Equipment Ground
*Line Neutral (White)
Breaker Box
Typical Two-Pole
Circuit Breaker
with GFCI
120/240 VAC Source
No Connection
(Load Neutral)
*Connections to be Made
at the Circuit Breaker
*L1
*L2
240 V
Bond in accordance with national and local codes. Open
bonding lugs are located at the top of the junction box.
Field Wire (From Junction
Box To GFCI Breaker)
Typical Wiring Connection for North America
Wire
Connector
Brown (L2)
Blue (L1)
From Control
Ground
(Green with
Yellow Stripe)
Electrician to
provide suitable
strain relief cable.
Control
Power
Supply
Control Power
Junction Box
Blower
Motor Cord
External Power
NOTE:
The product model number is printed on a label on the blower motor side of the bath with airjets.
This label also identi
fi
es the electrical rating of the product. All baths with airjets come equipped with a wiring
junction box and are designed to operate between 208 VAC and 240 VAC at either 50 Hz or 60 Hz.
WARNING: Risk of electric shock.
Make sure the power has been disconnected before performing the
following procedures. Refer to the “Important Information” section.
WARNING: Risk of electric shock
. Connect the control to a properly grounded Ground-Fault Circuit-
Interrupter (GFCI) or Residual Current Device (RCD). This will provide additional protection against
line-to-ground shock hazard. A 220-240 V, 15 A, 50/60 Hz dedicated circuit is required.
NOTICE:
The
load neutral
is not used. There should be no connection to the
load neutral
terminal on the
Ground-Fault Circuit-Interrupter (GFCI). The green wire with the yellow stripe is the
equipment ground
and
needs to be connected to the neutral bus in the main circuit breaker box.
NOTICE:
The bath with airjets control and system have been pre-wired at the factory. A quali
fi
ed electrician
should make a routine service connection to the junction box.
Connect service to the junction box. The junction box contains blue, brown, and green with a yellow stripe
colored wires. Follow local electrical codes. Bond in accordance with national and local codes.
NOTE:
A wiring harness has been pre-wired at the factory, allowing communication between the keypad, all
features, and the control. No additional wiring is required, but ensure that all wires are securely fastened.
NOTE:
Your wiring harness includes an antenna for the optional remote control. Do not alter or damage this
antenna during installation.
Proceed to the “Test Run the Bath with Airjets” section.