UDRF01.04GB
Maintenance manual DRF 400–450
D Error codes – 8 Control system
69
154
Incorrect control
breaker voltage to
Control unit frame
rear (D797-F).
–
Check cabling between the
control unit and component
with diagnostic menu.
Check component.
D797-R/
K2:11
CAN/
POWER,
menu 8
11.5.1.4 Con-
trol switch
voltage (15E)
155
5 V supply voltage
to sensor below 4.9
V or above 5.1 V.
–
Check cabling between the
control unit and component
with diagnostic menu.
Check component.
D797-R/
K1:8
CAN/
POWER,
menu 9
11.5.1 Voltage
feed
160
Transistor has been
triggered due to
short circuit or open
circuit in circuit for
Cooling fan hydrau-
lic oil (M668).
Cooling fan
hydraulic oil
not working.
Check cabling between the
control unit and component
with diagnostic menu.
Check component.
D797-R/
K1:14 –
M668
HYD,
menu 1
10.6.4 Cooling
fan
161
Transistor has been
triggered due to
short-circuit or
open circuit in cir-
cuit for light work
light boom left
(H406L-1).
Work light
boom left
not working.
Check light.
Check cabling between the
control unit and component
with diagnostic menu.
Check bulb socket.
D797-R/
K1:1 –
H406L-1
LIGHTS,
menu 3
9.6.11 Work
light boom
162
Transistor has been
triggered due to
short-circuit or
open circuit in cir-
cuit for light work
light boom right
(H406R-1).
Work light
boom right
not working.
Check light.
Check cabling between the
control unit and component
with diagnostic menu.
Check bulb socket.
D797-R/
K1:15 –
H406R-1
LIGHTS,
menu 3
9.6.11 Work
light boom
163
Transistor has been
triggered due to
short-circuit or
open circuit in cir-
cuit for light back-
up light left (H405L).
Back-up light
left not
working.
Check light.
Check cabling between the
control unit and component
with diagnostic menu.
Check bulb socket.
D797-R/
K1:28 –
H405L
LIGHTS,
menu 11
9.6.6 Back-up
light
164
Transistor has been
triggered due to
short-circuit or
open circuit in cir-
cuit for light back-
up light right
(H405R).
Back-up light
right not
working.
Check light.
Check cabling between the
control unit and component
with diagnostic menu.
Check bulb socket.
D797-R/
K1:42 –
H405R
LIGHTS,
menu 11
9.6.6 Back-up
light
Code
Description
Limitation
Action
Connec-
tion and
compo-
nent
Diag-
nostic
menu
Function
group
https://www.forkliftpdfmanuals.com/
Summary of Contents for DRF420-60S5
Page 2: ...https www forkliftpdfmanuals com ...
Page 4: ...UDRF01 04GB Maintenance manual DRF 400 450 2 AForeword https www forkliftpdfmanuals com ...
Page 18: ...UDRF01 04GB Maintenance manual DRF 400 450 2 BSafety https www forkliftpdfmanuals com ...
Page 60: ...UDRF01 04GB Maintenance manual DRF 400 450 2 1Engine https www forkliftpdfmanuals com ...
Page 86: ...UDRF01 04GB Maintenance manual DRF 400 450 2 2Transmission https www forkliftpdfmanuals com ...
Page 100: ...UDRF01 04GB Maintenance manual DRF 400 450 2 3Driveline axle https www forkliftpdfmanuals com ...
Page 106: ...UDRF01 04GB Maintenance manual DRF 400 450 2 4Brakes https www forkliftpdfmanuals com ...
Page 124: ...UDRF01 04GB Maintenance manual DRF 400 450 2 5Steering https www forkliftpdfmanuals com ...
Page 130: ...UDRF01 04GB Maintenance manual DRF 400 450 2 6Suspension https www forkliftpdfmanuals com ...
Page 150: ...UDRF01 04GB Maintenance manual DRF 400 450 2 7 Load handling https www forkliftpdfmanuals com ...
Page 320: ...UDRF01 04GB Maintenance manual DRF 400 450 2 D Error codes https www forkliftpdfmanuals com ...
Page 412: ...UDRF01 04GB Maintenance manual DRF 400 450 2 ESchematics https www forkliftpdfmanuals com ...