Benämning
Utgåva/Issue
Ritn.nr./ Drawing No.
Name
Klass/Class
H.Grp:
1
234
67
8
F
E
D
C
B
A
8
7
6
5
4
3
2
1
Godk/Appr
Ritad/Drawn
Konstr/Design
Datum/Date
Sign.
Ref.
Ruta
Nr
No.
Ändring
Design change
T=Tillk/Added U=Utgår/Deleted V=Var/Was
Ändring nr
Change No.
Sign.
Datum
Date
Sq.
Denna ritning får ej utan vårt medgivande kopieras.
Den får ej heller delgivas annan eller annars obe-
hörigen användas. Överträdelse härav beivras med
stöd av gällande lag.
This document must not be copied without our
written permission and the contents thereof must
not be imparted to a third party nor be used for any
unauthorized purpose. Contravention will be pro-
secuted.
DRAWING
R
E³
A
B
C
D
E
F
Blad/Sheet
Produkt/Product
5
Huvudnr./Project no.
A46087.0100
03
Krets Klimatsystem
Circuit Climate Control
DRFB 400-450
6
FSN
010412
RKO
031210
1
Reference Text Adjustment, Sync. Harnesses.
041478
TKB
040930
1
2
+CAB
A45209.0100
T
U
-B774
12
TEMP. AMBIENT
T
U
-B775-1
10 kOhm
12
TEMP. INDOOR
T
U
-B775-2
10 kOhm at 25°C
12
TEMP. FAN AIR
T
U
-B775-3
10 kOhm at 25°C
12
DEICING SENSOR
-X278f 5
-X005
7
-X005
8
-X005
10
-X005
9
-X033f 1
-X033f 2
-X033f 3
-X005 11
-X033f
5
-X033f 4
-X004 12
-X004
8
-X004
9
-X004
10
-X004
11
-X775-1
1
-X774
1
-X775-2
1
-X775-3
1
-X775-1 2
-X035f 7
-X775-2 2
-X035f 8
-X774 2
-X775-3 2
-X036f 8
-X221
23
-X035f
9
-X036f
9
-X033m
1
-X033m
2
-X033m
3
-X033m
4
-X033m 5
-X036m
8
-X035m
7
-X035m
8
-X035m 9
-X036m 9
/A44878.0100/1.D5 /A44878.0200/1.B3
246
P
-S246
+CHASSIS
12
REFRIGERANT
0,2 MPa
-X278m
5
1
2
-R8082
FAN SPEED
3
1
2
-R8083
TEMEPERATURE
3
1
2
-R8084
DRAUGHT VALVE
3
A43044.0100/2.C2
-D790-1
TEMP. INDOOR
Reostat in
K4:8
A43044.0100/2.C2
-D790-1
TEMP. AMBIENT
Reostat in
K4:9
A43044.0100/2.C2
-D790-1
TEMP. FAN AIR
Reostat in
K4:10
A43044.0100/2.C2
-D790-1
DEICING SENSOR
Reostat in
K4:11
A43044.0100/2.C2
-D790-1
TEMP SENSORS CAB
0V reference
K4:12
A43044.0100/2.C2
-D790-1
FAN SPEED
Analog Input
K5:7
A43044.0100/2.D2
-D790-1
TEMEPERATURE
Analog Input
K5:8
A43044.0100/2.D2
-D790-1
DRAUGHT VALVE
Analog Input
K5:9
A43044.0100/2.D2
-D790-1
CLIMATE CONTROL
0V reference
K5:10
A43044.0100/2.D2
-D790-1
CLIMATE CONTROL
Analog reference 5V
K5:11
A43044.0100/1.D6
-D797-R
+CHASSIS
PRESSURE REFRIGERANT
Analog Input
K1:23
-X039m
7
-X039f 7
-X065f
1
-X065m 1
-X039m 9
-X039f
9
-X065m
2
-X065f 2
-XS246-2 1
0048
00410
00411
0057
00510
0058
00511
WH
WH
YE
BU
YE
22123
BU
BU
BU
WH
WH
WH
BK
BK
BK
0059
2785
WH
00412A
00412B
00412C
A0397
0651
A0049
A0399
0652
https://www.forkliftpdfmanuals.com/
Summary of Contents for DRF420-60S5
Page 2: ...https www forkliftpdfmanuals com ...
Page 4: ...UDRF01 04GB Maintenance manual DRF 400 450 2 AForeword https www forkliftpdfmanuals com ...
Page 18: ...UDRF01 04GB Maintenance manual DRF 400 450 2 BSafety https www forkliftpdfmanuals com ...
Page 60: ...UDRF01 04GB Maintenance manual DRF 400 450 2 1Engine https www forkliftpdfmanuals com ...
Page 86: ...UDRF01 04GB Maintenance manual DRF 400 450 2 2Transmission https www forkliftpdfmanuals com ...
Page 100: ...UDRF01 04GB Maintenance manual DRF 400 450 2 3Driveline axle https www forkliftpdfmanuals com ...
Page 106: ...UDRF01 04GB Maintenance manual DRF 400 450 2 4Brakes https www forkliftpdfmanuals com ...
Page 124: ...UDRF01 04GB Maintenance manual DRF 400 450 2 5Steering https www forkliftpdfmanuals com ...
Page 130: ...UDRF01 04GB Maintenance manual DRF 400 450 2 6Suspension https www forkliftpdfmanuals com ...
Page 150: ...UDRF01 04GB Maintenance manual DRF 400 450 2 7 Load handling https www forkliftpdfmanuals com ...
Page 320: ...UDRF01 04GB Maintenance manual DRF 400 450 2 D Error codes https www forkliftpdfmanuals com ...
Page 412: ...UDRF01 04GB Maintenance manual DRF 400 450 2 ESchematics https www forkliftpdfmanuals com ...