18
14.0 Annual maintenance by the Authorized Assistance Centre
The following operations are to be programmed annually by the Authorized Assistance Centre and are necessary to insure
that the product remains efficient and guarantee safe operation.
• Careful cleaning of the combustion chamber;
• Cleaning and inspection of the smoke clearing ducts;
• Checking the seal of the gaskets;
• Cleaning the mechanisms and moving parts (motors and fans);
• Checking the electrical parts and the electronic components.
12.3 Season end cleaning
At the end of the season, when the insert will not be used for some time, it is advisable to perform a thorough and general cleaning:
• Remove all the pellets from the container and the screw feeder;
• Carefully clean the brazier, the brazier support, the combustion chamber and the ash box.
Once the preceding points have been observed, it only means that the state of the insert has been verified. It is necessary
to thoroughly clean the smoke discharge tube or flue and check the condition of the basket. If necessary, order a new
one from our Authorized Assistance Centre. If necessary, lubricate the hinges of the door and the handle. Also check the
ceramic fibre cord near the glass, on the internal wall of the door; if it is worn or too dry, order a new one from the Author-
ized Assistance Centre.
13.0 Replacing elements
13.1 Replacing the glass
The insert is furnished with a 4 mm thick ceramic glass that is resistant to a thermal shock of 750°C; the glass can break
only from a strong impact or from improper use.
Do not slam the door or hit the glass.
In case of breakage, replace the glass only with an original replacement furnished by the Authorized Assistance Centre.
Cleaning after 900 hours work or per year
Every time you reach 900 working hours or at least once a year, you need to clean the insert in all its
parts.
Join the following procedure to check the working hours on the display:
- Press the key SET 5 times until you reach the parameter UT04. Use the keys to increase or decrea-
se the temperature to reach 01. Confirm with the key SET. On the upper display you will read the
letters “Par” and on the lower display you will see the exact working hours of the insert.
- You will exit the working hours menu automatically after a few seconds you do not work on it.
!
14.1 Operations to perform every season before the first lighting.
• A general cleaning inside and outside;
• A careful cleaning of the exchange tubes;
• A careful cleaning and disincrustation of the crucible and the relative cavity;
• Clean the motors, checking the play and fastenings of the mechanisms;
• Clean the smoke channel (substitute the tube gaskets) and smoke extractor fan cavity;
• Clean silicone tube connected to the pressure switch;
• Clean, inspect and disincrust the lighting resistor cavity, replacing it if necessary;
• Clean/check the synoptic panel;
• Visually inspect the electrical cables, the connections and the electrical power cable;
• Clean the pellet container and verify the play with the screw feeder gear motor;
• Replace the door seals;
• Functional assessment, loading the screw feeder, lighting, 10 minutes of operation and shut down.
EN
Summary of Contents for Chiara 15
Page 22: ...20 NOTE Cod 001030A EN...