background image

3

Please remember that the first lighting must be performed by 
our certified Authorized Assistance Centre (Law 37/2008) that 
verifies the installation and completes the guarantee. 
During the first lighting the environment should be well ven-
tilated since during the first hours of operation unpleasant 
odours could develop due to the physical stabilizing of the paint 
and from the grease in the tubyère wrapping.

!

2.3 Suggestions

• Do not continuously turn the insert on and off as this could provoke sparks that could shorten the life of the electrical 

components;

• Do not touch the insert with wet hands: the insert has electrical components that could produce sparks if handled 

incorrectly. Only authorized technicians can resolve possible problems;

• Do not remove any screws from the fire chamber without first lubricating them well. 

• Never open the glass door of the pellet insert while the insert is in operation;

• Be sure that the brazier basket is positioned correctly.

3.0  Pellets’ loading in the pellet tank (Patent pending)

You can load the pellet in the pellet tank using the tray on the upper part of the insert. You can load the pellet in two ways:

• Remove the tray (Pict. 3); lift the supplied cab apron (shovel )(Pict. 4) so that you have a chute allowing the pellet to slide 

into the tank (Pict. 5) . Load now the pellet (Pict. 6).

Pict. 3

Pict. 4

Pict. 5

Once you have loaded the pellets, lift the tray so that all the pellets go to the pellet tank (fig. 7). Close the pellets 

tray (fig. 8).

Pict. 6

Pict. 7

Pict. 8

EN

Summary of Contents for Chiara 15

Page 1: ...USER MANUAL Paola 13 Chiara 15 Insert Air Stoves Instructions for the correct use and maintenance of your Kalor wood pellet air dry stove Distribution and warranty in Ireland by...

Page 2: ...port a nationwide network of Authorised Technicians who are specially trained on Kalor wood pellet stoves and boilers This ensures that your stove can be correctly installed commissioned maintained an...

Page 3: ...e Although the carefully studied design and the risk analysis done by our company has permitted the realization of a safe product in any case before effecting any operation on the insert it is recomme...

Page 4: ...use only quality pellets recommended by the manufacturer The glass is equipped with a special circulation of air for self cleaning but still it is not possible after several hours of operation to kee...

Page 5: ...ould produce sparks if handled incorrectly Only authorized technicians can resolve possible problems Do not remove any screws from the fire chamber without first lubricating them well Never open the g...

Page 6: ...ir proper operation this can lead to the termination of the guarantee and its producer responsibility For our products use pellets diameter 6 mm length 30 mm and a maximum of 6 and A1 certified accord...

Page 7: ...here is a warning EN Remove any components which might burn from the firebox and from the glass various instructions and adhesive labels Never remove the protection grille in the hopper When filling d...

Page 8: ...or and the cochlea engine are active BRAZIER CLEANING The Insert is cleaning the basket The smoke extractor runs at maximum speed and the pellet load is at minimum WORK The Insert is working in this c...

Page 9: ...for cleaning the Insert and the flue ALAR 4 FAN FAILURE Smokes extractor blocked or broken Contact an Authorized Assistance Center ALAR 5 NO LIGHTIN The Insert cannot start up This is the first light...

Page 10: ...1 and 2 select whether or not to activate the thermostat on off which allows you to program the automatic ignition of the Insert Once the thermostat is activated deactivated press button 4 OFF and con...

Page 11: ...saturday prog 1 on off 10 sunday prog 1 on off 11 start program 2 hour 12 stop program 2 hour 13 monday progr 2 on off 14 tuesday progr 2 on off 15 wednesday prog 2 on off 16 thursday prog 2 on off 1...

Page 12: ...ccording to the following table where the OFF setting tells the clock to ignore the command The weekly programmer has 4 independent programmes whose final effect is composed of the combination of the...

Page 13: ...FRIDAY PROGRAM 1 on off 02 03 09 SATURDAY PROGR 1 on off 02 03 10 SUNDAY PROGR 1 on off PROGRAMME 2 menu level selection meaning possible values 03 03 11 START PROGRAM 2 activation time time OFF 03 0...

Page 14: ...to reset the alarm Wait until the cooling phase is completed Clean the brazier and start a new light up These alarms remind you that the brazier must be cleaned and installed correctly before switchi...

Page 15: ...tion is set by default to OFF To activate this feature press SET 3 to access it STAND BY function is set by default to OFF 1 on the display you will see STAN BY MODE ON Press SET 3 to confirm and then...

Page 16: ...ines any responsibility Eventual variations in the colour of the metal parts can be caused by an incorrect use of the insert 11 0 Cleaning and maintenance 11 1 Ordinary cleaning to be done every day o...

Page 17: ...e holes by using a pointed tool not included with the insert This operation is made particularly necessary before every lighting the first several times and above all if using pellets that differ from...

Page 18: ...can in any case cause the glass to become dirty NOTE If the glass is broken do not attempt to light the insert 11 7 Ash box Open the door turn the two fastening knobs and remove the tray Remove all th...

Page 19: ...ual ash or dust rests Installa the insert again Place it on the support and push it slowly until it reaches the apposite check pin Check that the flue system lies perfectly in the T pipe Pict 20 how t...

Page 20: ...C the glass can break only from a strong impact or from improper use Do not slam the door or hit the glass In case of breakage replace the glass only with an original replacement furnished by the Aut...

Page 21: ...e can only take place following the unquestionable decision by the manufacturer in special cases 3 The Company declares no responsibility for any damage that may directly or indirectly result in perso...

Page 22: ...20 NOTE Cod 001030A EN...

Page 23: ...cturer It is very important to understand that any and all warranty claims may be rejected should your stove boiler not be commissioned by one of our Authorised Technicians See below for further detai...

Page 24: ...Wood Pellet Stoves ie Newport Co Mayo Ireland Tel 086 012 7744 Email info woodpelletstoves ie Web www woodpelletstoves ie...

Reviews: