38
GB
PARAMETER
UNIT OF
MEASURE
CAYENNE 14 - 14 C
CAYENNE 16 - 16 C
Heat input
kW
13,2
16,3
Nominal heat output
kW
12,5
15,2
Reduced heat output
kW
3,7
3,7
CO concentration at nominal
reference (13% O
2
)
mg/m
3
104,82
94,85
CO concentration at reduced
reference (13% O
2
)
mg/m
3
409,5
409,5
Nominal efficiency
%
94,76
93,48
Reduced efficiency
%
98
98
Pellet consumption (min-max)
Kg/h
0,78 - 2,72
0,78 - 3,44
Heated surface
mc
340
400
Flue gas flow rate (min-max)
g/s
2,83 - 7,29
2,83 - 8,53
Draft advised (min-max)
Pa
3 - 12
3 - 12
Flue gas temperature (min-max)
°C
46 - 112
46 - 139
Tank capacity
Kg
23
23
Recommended fuel
(ø x H)
mm
pellet 6 x 30
pellet 6 x 30
Diameter smoke outlet tube
mm
80
80
Diametro canalizzazione
mm
80
80
Diameter air intake
mm
50
50
Nominal voltage
V
230
230
Nominal frequency
Hz
50
50
Power consumption max
W
400
400
Stove weight
Kg
135 - 140
140 - 145
N° Test Report
K19052016T1
The pellets are cylinders of compressed wood, produced from sawdust and wood processing (chips and
sawdust), generally produced by sawmills and carpenters. The binding capacity of the lignin contained
in wood, allows to obtain a compact product without adding additives and foreign chemicals to the
wood, is therefore obtained a natural fuel with high yield.
The use of expired pellets or any other unsuitable material can damage parts of
the stove and impair proper operation: this can lead to the termination of the
guarantee, and its producer responsibility.
For our stoves use pellets diameter 6 mm, length 30 mm and a maximum
of 8% moisture. Store the pellets away from heat sources and not in
humid environments or with explosive atmospheres.
Pellet
It is recommended that the control of emissions after installation.