background image

39

GB

Charge pellet

Fuel is loaded from the upper part of the stove by opening 
a door. Pour the pellets in the hopper. When empty, it will 
hold slightly more than 23 kg.
This is easier if performed in two steps:
• Pour half of the contents of the bag into the hopper and 
wait for the fuel to settle on the bottom.
• Then pour in the rest.

The brazier should be cleaned before each 
starting.

Never  remove  the  protection  grille  in  the 

hopper. When filling, do not let the sack of 
pellets touch any hot surfaces.

Remove any components which might 
burn from the firebox and from the glass 
(various instructions and adhesive labels).

First lighting of the stove

• Before switching on, make sure that the grate is clean and 
empty of any pellet residues from previous combustions. 
Otherwise make sure you empty and clean it
• Fill the container 3/4 full with the pellets recommended 
by the manufacturer
• Connect the stove to an electrical outlet with the cable 
that has been supplied
• Press the lighting switch located on the back part of the 

stove

• The upper display will read “

O F F

• Press the button   for 2 seconds. After a few moments 
the  smoke  extractor  and  the  lighting  resistor  will  start 
and  the  display  will  read  “

S T A R T

”;  The  led  resistance  is 

switched on
• After 1 minute the display will read “

L O A D   P E L L E T

”, the 

stove will load the pellets and continue lighting the resistor
•  Once  the  appropriate  temperature  has  been  reached 
the display will read “

F L A M E   L I G H T

”: this means that the 

stove has begun the last phase in lighting, at the end of 
which  the  stove  will  be  completely  operational;  The  led 
resistence is switched off
•  After  some  minutes  the  display  will  show  the  words 

W O R K

 alternating room temperature and current working 

power. The stove is now completely on
•  When the stove reaches the set temperature, the display 
will show “

M O D U L A T I O N

.

Stove start up

We highly recommend to turn to our 

Authorized Service Centre for the 
installation and the first ignition of the 

device as it not only carries out the installation 
perfectly but also verifies the regular operation of it. 
During the first lighting the environment should 
be well ventilated since during the first hours of 
operation unpleasant odours could develop due to 
the physical stabilizing of the paint and from the 
grease in the tube bundle.

Before lighting a small amount of smoke 
may fill the combustion chamber.

Stove switching off

To  switch  off  the  stove,  press  the  key 

 

on  the  control 

board  until  you  read  “

C L E A N I N G   F I N A L

”  on  the  display. 

After the stove has been switched off, the fan continues 

working for a set time in order to grant a fast smokes 

exhaust from the combustion chamber. 
If you have a model with remote control, you just need to 
switch the remote control off keeping the key pressed for 
2 seconds and confirming the selection pressing the key 
SEND.
If  you  try  to  switch  on  the  stove  during  this  phase,  the 
display will show “

w a i t i n g   c o o l i n g

” (that means wait for 

cooling)  in  order  to  inform  you  a  switching  off  phase  is 
running. Wait until the cooling phase is completely off and 
the display shows “

O F F

” before staring a new light up.

REMARKS

:

•  Do  not  continuously  turn  the  stove  on  and  off  as  this 
could  provoke  sparks  that  could  shorten  the  life  of  the 

electrical components.

•  Do  not  touch  the  stove  with  wet  hands:  the  stove 
has  electrical  components  that  could  produce  sparks 
if  handled  incorrectly.  Only  authorized  technicians  can 

resolve possible problems.

• Do not remove any screws from the fire chamber without 
first lubricating them well. 
• Never open the glass door of the pellet stove while the 

stove is in operation.

• Be sure that the brazier basket is positioned correctly.
• The flue system must be suitable for inspecion. If it cannot 
be removed, it must have some holes for inspection and 

cleaning.

Summary of Contents for Denia 14

Page 1: ...INSTALLER USER MANUAL For Denia 14 14D Mia 16 16D...

Page 2: ...e door handle sides can reach high temperatures There fore pay attention and use the proper precautions above all in the presence of children elderly or disabled persons and animals Assembly must be p...

Page 3: ...for accidents deriving from the partial or total lack of observance of the instructions contained herein We decline every responsibility derived from improper use of the stove from incorrect use by t...

Page 4: ...ance Do not use the stove as a ladder or scaffold Do not put clothes to dry on the stove Any clothes hangers and suchlike must be kept a suitable distance from the stove Risk of fire Carefully explain...

Page 5: ...its weight If walls are flammable maintain a minimum distance of 20 cm at the rear A of 30 cm at the side B and 100 cm at the front If the room contains objects which are believed to be particularly...

Page 6: ...nless steel pipe must not be used At the bottom of the flue pipe provide an inspection cap to allow periodic checking and cleaning which must be done annually Make a gas tight connection to the flue p...

Page 7: ...of type and must be above the ridge Eventual structures or other obstacles that are higher than the chimney cap must not be too close to the chimney cap itself The device should not be installed in th...

Page 8: ...nothermostat 1 2 3 SET 4 5 6 This signalises that the automatic single or daily switching on or off of the stove is on The automatic programming can be set only using the remote control Resistance ind...

Page 9: ...8 88 175 495 50 Air Intake 8 0 S m o k e O u t l e t 80 Channeling If Any 1020 1084 269 296 457 30 Theremotecontrol Fig 3 usedtoadjustwatertemperature power and the on off functions for the pellet sto...

Page 10: ...00 0 5 0 4 400 120 2 1 5 4000 2000 1 1 2 2000 1000 DA A 2 5 3 5 OLTRE CAMPO TOLLERANZA LUNGH LATO CORTO 3 FINO A 10 2 DA 10 A 50 1 DA 50 A 150 30 OLTRE 150 A A A A A DA DA DA DA DA 36030 San Vito di L...

Page 11: ...230 230 Nominal frequency Hz 50 50 Power consumption max W 400 400 Stove weight Kg 135 140 140 145 N Test Report K19052016T1 The pellets are cylinders of compressed wood produced from sawdust and wood...

Page 12: ...erature the display will show MODULATION Stove start up We highly recommend to turn to our Authorized Service Centre for the installation and the first ignition of the device as it not only carries ou...

Page 13: ...buttons 1 and 2 select whether or not to activate the thermostat on off which allows you to program the automatic ignition of the stove Once the thermostat is activated deactivated press button 4 OFF...

Page 14: ...og 2 on off 16 thursday prog 2 on off 17 friday prog 2 on off 18 saturday prog 2 on off 19 sunday prog 2 on off 20 start program 3 hour 21 stop program 3 hour 22 monday progr 3 on off 23 tuesday progr...

Page 15: ...programmes PROGRAMME 1 menu level selection meaning possible values 02 03 02 START PROGRAM 1 activation time time OFF 02 03 03 STOP PROGRAM 1 shut off time time OFF 02 03 04 MONDAY PROGRAM 1 reference...

Page 16: ...5 6 1 and 1 2 3 SET 4 5 6 2 Stand by mode This mode allows the automatic shutdown of the stove once it reaches the temperature set on SET When this happens the stove will wait a few minutes factory se...

Page 17: ...SET key to access the menu to set the speed of your funnel fans 3 Set the speed using the buttons 1 and 2 With key 1 you set the speed of the right fan with key 2 you set the speed of the left fan 4 T...

Page 18: ...tilator gear motor and room ventilator are on during this phase 14 35 21 C P 2 LOAD pellet 14 35 21 C P 2 FLAME LIGHT 15 18 21 C P 3 WORK 5 16 40 22 C P 2 CLEANING FIRE POT Regular checks should be ca...

Page 19: ...irty If the glass is broken do not attempt to light the stove Cleaning the ceramic covering if supplied The ceramic tiling must be cleaned with a soft dry cloth before using a damp cloth Use only neut...

Page 20: ...ttom of the chamber combusione and the compartment that is located below the ash box photo 8 Also clean the brazier and the ash box After completing the cleaning replace the refractory its attachment...

Page 21: ...y per formance It is therefore necessary to clean the fans at least once a year Since said operation requires dismantling several parts of the stove have the fans cleaned only by our Technical As sist...

Page 22: ...ollection compartment Cleaning ash tray Cleaning the door and glass Cleaning the interior heat exchanger smoke fan compartment Cleaning complete exchanger Clean T to exhaust Flue Door gasket ash Inter...

Page 23: ...ion or shuts the stove when the flue gas temperature drops below the preset value Electrical safety the stove is protected against violent surg es of current ex lightnings by the main fuse 4 A which i...

Page 24: ...pted 6 Card defective 1 Check that the power cord is connected 2 Use the switch back to operate it 3 Unplug the stove from the power outlet for about one minute and then turn on If the problem persist...

Page 25: ...se the drawer ashtray 10 Perform periodic cleaning 11 Check the operation of the extractor flue 12 Contact an authorized service center 13 Make sure the place of stowage pellet and re place it with a...

Page 26: ...xhaust fumes Contact your Authorized Service Center 7 Check the quality of the pellets Contact your Authorized Service Center 8 Increase the level in the parameters relating to the speed of the fan ex...

Page 27: ...oreign objects 7 Close the door or replace the gaskets with original 8 Change the type of pellet recommended by the manufacturer Sometimes depending on the type the stage of adjustment of the paramete...

Page 28: ...55 GB NOTES...

Page 29: ...56 GB NOTES...

Reviews: