45
GB
Display informations
Alarm signals
OFF
The stove is off.
21:10
22°C
P-1
OFF
14:35
21°C
P-2
START
14:35
21°C
P-2
LOAD
pellet
14:35
21°C
P-2
FLAME
LIGHT
15:18
21°C
P-3
WORK
(5)
16:40
22°C
P-2
CLEANING
FIRE-POT
START
The stove is switching on.
Resistance and smokes extractor
are on.
21:10
22°C
P-1
OFF
14:35
21°C
P-2
START
14:35
21°C
P-2
LOAD
pellet
14:35
21°C
P-2
FLAME
LIGHT
15:18
21°C
P-3
WORK
(5)
16:40
22°C
P-2
CLEANING
FIRE-POT
LOAD PELLET
The stove starts loading pellets in
the brazier.
Resistance, smokes extractor and
gear motor are on.
21:10
22°C
P-1
OFF
14:35
21°C
P-2
START
14:35
21°C
P-2
LOAD
pellet
14:35
21°C
P-2
FLAME
LIGHT
15:18
21°C
P-3
WORK
(5)
16:40
22°C
P-2
CLEANING
FIRE-POT
FLAME LIGHT
The stove starts loading pellets in
the brazier.
Smokes extractor and gear mo-
tor are on.
21:10
22°C
P-1
OFF
14:35
21°C
P-2
START
14:35
21°C
P-2
LOAD
pellet
14:35
21°C
P-2
FLAME
LIGHT
15:18
21°C
P-3
WORK
(5)
16:40
22°C
P-2
CLEANING
FIRE-POT
CLEANING FIRE-POT
The stove is cleaning the brazier.
The smokes extractor is working
at its max. speed and the pellets
loading is minimal.
21:10
22°C
P-1
OFF
14:35
21°C
P-2
START
14:35
21°C
P-2
LOAD
pellet
14:35
21°C
P-2
FLAME
LIGHT
15:18
21°C
P-3
WORK
(5)
16:40
22°C
P-2
CLEANING
FIRE-POT
WORK
The stove is working, in this case
with working power 3. Detected
room temperature is 21°C. Smokes
ventilator, gear motor and room
ventilator are on during this phase.
21:10
22°C
P-1
OFF
14:35
21°C
P-2
START
14:35
21°C
P-2
LOAD
pellet
14:35
21°C
P-2
FLAME
LIGHT
15:18
21°C
P-3
WORK
(5)
16:40
22°C
P-2
CLEANING
FIRE-POT
Regular checks should be carried out by the user, who should only contact the Authorized Assistance Center
if no solution is found.
In the event of a working defect, the system informs the user about the type of failure occurred.
The following table summarises the alarms, kind of problem and possible solution:
Upper
Display
Lower
Display
Kind of failure
Solution
AL 5
The cannot start up
This is the first light-up
Fill in the tank with pellets
Start up again
AL 6
NO
PELLET
The pellet stove switched off while work-
ing
Fill in the tank with pellets
AL 2
PROBE
EXHAUST
The smokes sensor is broken or not
connected to the pcb
Contact an Authorized Assistance Center
AL 7
SAFETY
THERMAL
The stove is overheated
Reset the thermostat manually. If the problem persists,
contact an
Authorized Assistance Center.
COOL
FIRE
There is no power supply
As soon as the power supply is back, the stove starts a cool-
ing cycle. After completing the cycle it starts working auto-
matically
AL 4
FAN
FAILURE
Smokes extractor blocked or broken
Contact an Authorized Assistance Center
AL 8
FAILURE
DEPRESS
Obstructed flue
Clean the flue or check there are no obstructed grids near the
smokes exhaust
SERVICE
The stove has worked for 1300 hours.
Supplementary maintenance required
Contact an Authorized Assistance Center