54
GB
The manufacturer of the stove any liability and will void the warranty terms of the product for any
inconvenience caused by not following the rules described above. Any work of service center will
be borne by the applicant if they are not complied with these instructions.
The fire goes out or
the stove stops auto-
matically
1. The pellet tank is empty
2. No power
3. Pellets not being fed
4. Excessive deposit of ashes in
the grate
5. Intervention probe temperature
safety of the pellet
6. Cochlea blocked by dirt
7. The door is not closed prop-
erly or gaskets worn
8. Pellet inadequate
9. Low pellet
10. Chimney or drain clogged
with nests or foreign bodies
11. Pressure switch cuts
12. Smoke extraction motor
failure
13. Alarm active
1. Fill the tank with pellets
2. Check plug and presence electricity
3. Fill the tank with pellets
4. Clean the brazier
5. Let the stove cool down completely, reset the
manual reset and restart the stove. If the problem
persists, contact your authorized service representa-
tive
6. Pull the plug, empty the tank, remove any foreign
objects
7. Close the door or replace the gaskets with original
8. Change the type of pellet recommended by the
manufacturer.
Sometimes, depending on the type,
the stage of adjustment of the parameters need
to vary the level relating to the loading of pellets
9. Increase the level in the parameter for the pel-
let feed. T
o check the flow of fuel from technical
authorized
10. Eliminate all foreign matter from the chimney
Clean the smoke duct. Perform periodic cleaning.
11. Verify potential smoke duct is blocked and if
the pressure switch is working properly
12. Check and replace the motor if necessary
13. See paragraph alarms
The air fan convention
(ambient air) never
stops
1. Temperature sensor tempera-
ture control defective or broken
2. Smoke probe fails
1. Check the operation of the sensor and replace if
necessary
2. Replace smoke probe
The stove does not
light.
1. Lack of electricity
2. Probe pellets in bulk
3. Fuse blown
4. Pressure switch broken (lock-
out indicated)
5. Smoke outlet or duct clogged
1. Check that the electrical outlet is plugged in and
the power switch to "I"
2. Lockout by resetting the rear thermostat,
replace
the thermostat
if it happens again
3. Replace the fuse
4. Replace the pressure
5. Clean the smoke outlet and / or smoke duct
Summary of Contents for Denia 14
Page 1: ...INSTALLER USER MANUAL For Denia 14 14D Mia 16 16D...
Page 28: ...55 GB NOTES...
Page 29: ...56 GB NOTES...