background image

34

GB

Function chrono-thermostat
(available only through the remote control)

With  the  function  chrono-thermostat,  you  can  schedule 

up to two automatic switching on and off of the stove per 
day.

If you want to repeat the switching on and off every day, 

then you need to use the function AUTO too (as explained 
in the paragraph “Daily repeat AUTO”).

Program 1 (ON1 and OFF1)
Automatic switching on ON1

Please 

join 

the 

following 

procedure  to  set  the  time  for 
the  automatic  switching  on 
according to the program 1:
Press  the  key 

  (1).  You  will 

see the hours and minutes and 
the symbol ON1 blinking on the 
remote  control.  Use  the  keys

 (2) and 

 (3) to change 

the  wished  time  (intervals  of 
10  minutes).  To  scroll  the  time 
faster,  keep  the  keys 

  (2) 

and 

 (3) pressed.

Confirm your selection pressing 
the key 

 (1) once again.

You will now read the set switching on time on the remote 
control. Press SEND (4) to transmit your selection to the 
pcb of the stove.
The  LED  chrono-thermostat  will  light  up  on  the  control 
board indicating that the programming is on (5).

AL C

AL F

5

1

2

ON 1

4

• The time of the automatic switching on 

and off must be set when the remote 
control is Off;

• In the event of an even very short lack of current, 

you will miss the set time for the automatic 
switching on or off. Once the power supply is 
back, please program the stove again using the 
remote control;

• The stove switching on at the scheduled time will 

keep the same temperature and power you set 
before you last switched it off;

•  Please  consider  an  interval  of  min.  20  minutes 

between the switching off and subsequent 
switching on of the stove. In this way the unit 
will have time to arrange a complete cooling 
phase; in the event this minimal interval is 
not calculated, the stove will not switch on as 
scheduled.

Automatic switching off OFF1

Press  the  key 

  (1).  You  will 

see the hours and minutes and 
the symbol OFF1 blinking on the 
remote  control.  Use  the  keys 

 (2) and 

 (3) to change 

the  wished  time  (intervals  of 
10  minutes).  To  scroll  the  time 
faster,  keep  the  keys 

  (2) 

and 

 (3) pressed.

Confirm your selection pressing 
the key 

 (1). once again.

You  will  now  read  the  set 
switching off time on the remote 
control.  Press  SEND  (4)  to 
transmit your selection to the pcb of the stove.
The  LED  chrono-thermostat  will  light  up  on  the  control 
board indicating that the programming is on (5). 
The  LED  chronothermostat  switches  off  as  soon  as  the 
automatic switching on and off are completed.
The remote control does not show the previously set time 
schedule anymore.

OFF1

1

3

2

4

Program 2 (ON2 and OFF2)
As above but with the keys 
ON2 and OFF2

Cancel any eventual already 
set timetables.

Please  join  the  following 
procedure  to  cancel  any  other 
already  set  timetables.  This 
example refers to the automatic 
switching  off  of  the  program 
1  (Off1).  The  procedure  is  the 
same for all plans.
Press the key corresponding to 
the switching on or off time you want to cancel.
Referring to the example: press the key 

 (1).

You will see the hours and minutes and the symbol OFF1 
blinking on the display of the remote control. Now press 
the key “CANCEL” (2) to cancel the automatic switching 
on or off timetables from the display.
Press  the  key  SEND  (3)  to  confirm  your  selection  and 
transmit it to the pcb of the stove. 

2

1

3

Summary of Contents for Mignon 6

Page 1: ...INSTALLER USER MANUAL For Petite 6 Air Stove...

Page 2: ...the stove door handle sides can reach high temperatures Therefore pay attention and use the proper precautions above all in the presence of children elderly or disabled persons and animals Assembly m...

Page 3: ...servance of the instruc tions contained herein We decline every responsibility derived from improper use of the stove from incorrect use by the user from un authorized modifications and or repairs fro...

Page 4: ...eaning and maintenance to be performed by the user should not be made by children without supervision Do not use the stove as a ladder or scaffold Do not put clothes to dry on the stove Any clothes ha...

Page 5: ...t not be less than 30 m3 The air must come in through permanent openings made in walls in proximity to the stove which give onto the outside with a minimum cross section area of 100 cm2 These openings...

Page 6: ...nless steel pipe must not be used At the bottom of the flue pipe provide an inspection cap to allow periodic checking and cleaning which must be done annually Make a gas tight connection to the flue p...

Page 7: ...different dimensions and forms according to the angle of inclination of the roof so it is necessary to adopt minimum heights The chimney cap must be a wind proof type and must be above the ridge Event...

Page 8: ...you will read the word Eco and the set temperature on the display 9 This led blinks every time the stove is loading pellets 10 This led is on only while the stove is lighting up in order to indicate...

Page 9: ...automatic switching on of the stove program 1 OFF1 Using this key you can set a single time schedule for the automatic switching off of the stove program 1 ON2 Using this key you can set a single time...

Page 10: ...fferent selections from the remote control the stove will restart working as it did before you activated the turbo function Keep the key TURBO 1 pressed for at least two seconds to activate this funct...

Page 11: ...n 20 minutes between the switching off and subsequent switching on of the stove In this way the unit will have time to arrange a complete cooling phase in the event this minimal interval is not calcul...

Page 12: ...reheating the resistor preceding lighting LOAD WOOD the stove is loading pellets On the control board the LED resistance is on FIRE ON The stove is in the flame stabilization phase flame present ON 1...

Page 13: ...Data Dis A DESCRIZIONE Modifica B C D E F G MZ ASSIEME 6KW ESTETICA MIGNON 41547 g 17 05 2016 Via delle Arti e dei Mestieri 1 3 H I Trattamento 4705001 v e R e c i d o C 1 5 770 487 32 431 25 174 158...

Page 14: ...e weight Kg 45 N Test Report K18532016T1 It is recommended that the control of emissions after installation The pellets are cylinders of compressed wood produced from sawdust and wood processing chips...

Page 15: ...erature the display will show MODULATION Stove start up We highly recommend to turn to our Authorized Service Centre for the installation and the first ignition of the device as it not only carries ou...

Page 16: ...cur also when there is not enough pellets flow to light up the unit Press the key On Off on the control board to reset the alarm Wait until the cooling phase is completed clean the brazier and start u...

Page 17: ...Cleaning the glass The glass is a self cleaning type therefore while the stove is working a veil of air is blown across its surface to remove ash and dirt nevertheless over a period of several hours...

Page 18: ...ar and below the stove Eventual deposits of dust or ash on the blades of the fan can cause an imbalance in the fans leading to noisy performance It is therefore necessary to clean the fans at least on...

Page 19: ...ollection compartment Cleaning ash tray Cleaning the door and glass Cleaning the interior heat exchanger smoke fan compartment Cleaning complete exchanger Clean T to exhaust Flue Door gasket ash Inter...

Page 20: ...body stove RESTART PELLET Reduction motor if the motor stops the thermostove continues to function until the flame goes out for lack of fuel and until It has cooled down to the minimum level Flue gas...

Page 21: ...pted 6 Card defective 1 Check that the power cord is connected 2 Use the switch back to operate it 3 Unplug the stove from the power outlet for about one minute and then turn on If the problem persist...

Page 22: ...se the drawer ashtray 10 Perform periodic cleaning 11 Check the operation of the extractor flue 12 Contact an authorized service center 13 Make sure the place of stowage pellet and re place it with a...

Page 23: ...xhaust fumes Contact your Authorized Service Center 7 Check the quality of the pellets Contact your Authorized Service Center 8 Increase the level in the parameters relating to the speed of the fan ex...

Page 24: ...oreign objects 7 Close the door or replace the gaskets with original 8 Change the type of pellet recommended by the manufacturer Sometimes depending on the type the stage of adjustment of the paramete...