background image

47

GB

The manufacturer of the stove any liability and will void the warranty terms of the product for any 
inconvenience caused by not following the rules described above. Any work of service center will 
be borne by the applicant if they are not complied with these instructions.

The fire goes out or 
the stove stops auto-
matically

1. The pellet tank is empty
2. No power
3. Pellets not being fed
4. Excessive deposit of ashes in 
the grate
5. Intervention probe temperature 
safety of the pellet
6. Cochlea blocked by dirt
7. The door is not closed prop-
erly or gaskets worn
8. Pellet inadequate
9. Low pellet
10. Chimney or drain clogged 
with nests or foreign bodies
11. Pressure switch cuts
12. Smoke extraction motor 
failure
13. Alarm active

1. Fill the tank with pellets
2. Check plug and presence electricity
3. Fill the tank with pellets
4. Clean the brazier
5. Let the stove cool down completely, reset the 
manual reset and restart the stove. If the problem 
persists, contact your authorized service representa-
tive
6. Pull the plug, empty the tank, remove any foreign 
objects
7. Close the door or replace the gaskets with original
8. Change the type of pellet recommended by the 
manufacturer. 

Sometimes, depending on the type, 

the stage of adjustment of the parameters need 
to vary the level relating to the loading of pellets

9. Increase the level in the parameter for the pel-
let feed. T

o check the flow of fuel from technical 

authorized

10. Eliminate all foreign matter from the chimney 
Clean the smoke duct. Perform periodic cleaning.

11. Verify potential smoke duct is blocked and if 
the pressure switch is working properly
12. Check and replace the motor if necessary

13. See paragraph alarms

The air fan convention 
(ambient air) never 
stops

1. Temperature sensor tempera-
ture control defective or broken
2. Smoke probe fails

1. Check the operation of the sensor and replace if 
necessary
2. Replace smoke probe

The stove does not 
light.

1. Lack of electricity
2. Probe pellets in bulk
3. Fuse blown
4. Pressure switch broken (lock-
out indicated)
5. Smoke outlet or duct clogged

1. Check that the electrical outlet is plugged in and 
the power switch to "I"
2. Lockout by resetting the rear thermostat, 

replace 

the thermostat

 if it happens again

3. Replace the fuse

4. Replace the pressure

5. Clean the smoke outlet and / or smoke duct

Summary of Contents for Petite 6

Page 1: ...INSTALLER USER MANUAL For Petite 6 Air Stove...

Page 2: ...the stove door handle sides can reach high temperatures Therefore pay attention and use the proper precautions above all in the presence of children elderly or disabled persons and animals Assembly m...

Page 3: ...servance of the instruc tions contained herein We decline every responsibility derived from improper use of the stove from incorrect use by the user from un authorized modifications and or repairs fro...

Page 4: ...eaning and maintenance to be performed by the user should not be made by children without supervision Do not use the stove as a ladder or scaffold Do not put clothes to dry on the stove Any clothes ha...

Page 5: ...t not be less than 30 m3 The air must come in through permanent openings made in walls in proximity to the stove which give onto the outside with a minimum cross section area of 100 cm2 These openings...

Page 6: ...nless steel pipe must not be used At the bottom of the flue pipe provide an inspection cap to allow periodic checking and cleaning which must be done annually Make a gas tight connection to the flue p...

Page 7: ...different dimensions and forms according to the angle of inclination of the roof so it is necessary to adopt minimum heights The chimney cap must be a wind proof type and must be above the ridge Event...

Page 8: ...you will read the word Eco and the set temperature on the display 9 This led blinks every time the stove is loading pellets 10 This led is on only while the stove is lighting up in order to indicate...

Page 9: ...automatic switching on of the stove program 1 OFF1 Using this key you can set a single time schedule for the automatic switching off of the stove program 1 ON2 Using this key you can set a single time...

Page 10: ...fferent selections from the remote control the stove will restart working as it did before you activated the turbo function Keep the key TURBO 1 pressed for at least two seconds to activate this funct...

Page 11: ...n 20 minutes between the switching off and subsequent switching on of the stove In this way the unit will have time to arrange a complete cooling phase in the event this minimal interval is not calcul...

Page 12: ...reheating the resistor preceding lighting LOAD WOOD the stove is loading pellets On the control board the LED resistance is on FIRE ON The stove is in the flame stabilization phase flame present ON 1...

Page 13: ...Data Dis A DESCRIZIONE Modifica B C D E F G MZ ASSIEME 6KW ESTETICA MIGNON 41547 g 17 05 2016 Via delle Arti e dei Mestieri 1 3 H I Trattamento 4705001 v e R e c i d o C 1 5 770 487 32 431 25 174 158...

Page 14: ...e weight Kg 45 N Test Report K18532016T1 It is recommended that the control of emissions after installation The pellets are cylinders of compressed wood produced from sawdust and wood processing chips...

Page 15: ...erature the display will show MODULATION Stove start up We highly recommend to turn to our Authorized Service Centre for the installation and the first ignition of the device as it not only carries ou...

Page 16: ...cur also when there is not enough pellets flow to light up the unit Press the key On Off on the control board to reset the alarm Wait until the cooling phase is completed clean the brazier and start u...

Page 17: ...Cleaning the glass The glass is a self cleaning type therefore while the stove is working a veil of air is blown across its surface to remove ash and dirt nevertheless over a period of several hours...

Page 18: ...ar and below the stove Eventual deposits of dust or ash on the blades of the fan can cause an imbalance in the fans leading to noisy performance It is therefore necessary to clean the fans at least on...

Page 19: ...ollection compartment Cleaning ash tray Cleaning the door and glass Cleaning the interior heat exchanger smoke fan compartment Cleaning complete exchanger Clean T to exhaust Flue Door gasket ash Inter...

Page 20: ...body stove RESTART PELLET Reduction motor if the motor stops the thermostove continues to function until the flame goes out for lack of fuel and until It has cooled down to the minimum level Flue gas...

Page 21: ...pted 6 Card defective 1 Check that the power cord is connected 2 Use the switch back to operate it 3 Unplug the stove from the power outlet for about one minute and then turn on If the problem persist...

Page 22: ...se the drawer ashtray 10 Perform periodic cleaning 11 Check the operation of the extractor flue 12 Contact an authorized service center 13 Make sure the place of stowage pellet and re place it with a...

Page 23: ...xhaust fumes Contact your Authorized Service Center 7 Check the quality of the pellets Contact your Authorized Service Center 8 Increase the level in the parameters relating to the speed of the fan ex...

Page 24: ...oreign objects 7 Close the door or replace the gaskets with original 8 Change the type of pellet recommended by the manufacturer Sometimes depending on the type the stage of adjustment of the paramete...

Page 25: ...48 GB NOTES Cod 001124...