52
EN
Maintenance and cleaning
All cleaning of all parts must be carried out with the stove
completely cold and unplugged to avoid burns and thermal shock.
The stove does not need much maintenance if used with certifi
ed
quality pellet. The need for maintenance varies depending on the conditions of use
(switching on and off repeatedly) and depending on the performance required.
Parts
Everyday
Every 2-3
days
Every week
Every 15
days
Every 30
days
Every 60-
90 days
Every year /
1200-1400 h
Brazier
◊
Cleaning the scraper
(where present)
◊
Cleaning ash collection
compartment
◊
Cleaning ash tray
◊
Cleaning the door and glass
◊
Flame-shell cleaning
(where present)
◊
Cleaning the interior heat
exchanger /
smoke fan compartment
•
Cleaning complete exchanger
•
Clean “T” to exhaust
•
Flue
•
Door gasket ash
•
Internal parts
•
Flue pipe
•
Electromechanical
components
•
◊ by the user
•
by the authorised qualifi ed technical assistance
Every 1200 hours of work the electronic board sends a warning signal and the
display will show
“SERVICE”
. This indicates the need for a thorough cleaning of the
stove by a CAT. The lack of such cleaning could result in failure of the stove and poor
combustion, thereby resulting in a lower yield.
Summary of Contents for QUADRA 12D
Page 1: ...USER MANUAL QUADRA 12D...
Page 24: ...54 EN...
Page 33: ...63 EN NOTES Cod 001109...
Page 34: ...64 EN NOTES Cod 001109...