background image

34

EN

Our company declares that the stove conforms to the 
following norms for the EC European Directive labelling:
• 2014/30 UE (regulation EMCD) and following 

 

     amendments;
• 2014/35 UE (Low Voltage Directive) and following 

 amendments;

• 2011/65 EU (RoHS 2 directive);
• The New Rules of Construction Products (CPR-

Construction Products Regulation) No. 305/2011 
regarding the construction world;

• For installations in Italy, please refer to UNI 10683/98 or 

following changes. 

While installing the unit respect 

the local, national and Europen rules;

• EN 55014-1; EN 55014-2; EN 61000-3-2; EN 61000-3-3; 

EN 60335-1; EN 60335-2-102; EN 62233, EN 50581.

Safety information

Please carefully read this use and maintenance manual 
before installing and operating the stove.
If clarification is needed, please contact the dealer or the 
Authorized Assistance Center.
• The pellet stove must only be operated in living 

environments. This stove, being controlled by an 
electronic board, permits a completely automatic and 
controlled combustion; the exchange, in fact, regulates 
the lighting phase, 5 power levels and the shut down 
stage, guaranteeing the safe operation of the stove.

• The basket used for combustion allows most of the ash 

produced by the combustion of the pellets to fall into 
the collection compartment. Nevertheless, check the 
basket daily, given that not all pellets have high quality 
standards (use only quality pellets recommended by the 
manufacturer).

Responsibility

With the delivery of the present manual, we decline 
all responsibility, both civil and penal, for accidents 
deriving from the partial or total lack of observance 
of the instructions contained herein. We decline every 
responsibility derived from improper use of the stove, 
from incorrect use by the user, from unauthorized 
modifications and/or repairs, from the use of replacement 
parts that are not original for this model.
The manufacturer declines every civil or penal, direct or 
indirect responsibility due to:
•  Lack of maintenance;
• Failure to observe the instructions contained in the 
manual;
• Use in non-conformity with the safety directives;

• Installation in non-conformity with the norms in force in 
the country;
• Installation by unqualified or untrained personnel;
• Modifications and repairs not authorized by the manu-
facturer;
• Use of non-original replacement parts;
• Exceptional events.

Norms and declarations of conformity

• Use only wood pellets;
• Keep / store the pellets in a cool dry 

place;

• Never pour pellets directly on the hearth;
• The stove must be fueled only with quality pellets 

with a diameter of 6 mm and a maximum length 
of 30 mm, A1 certified according to the UNI EN 
ISO 17225-2 standard, the type recommended 
by the manufacturer.

• Before making the electrical connection of the 

stove the discharge tubes must be connected 
with the flue;

• The protective grill placed inside the pellet 

container must never be removed;

• The environment where the stove is installed 

must have a sufficient exchange of air;

• It is forbidden to operate the stove with the door 

open or the glass broken;

• Do not use the stove as an incinerator; the stove 

should be used only for the intended purpose;

• Any other use is considered improper and 

therefore dangerous. Do not put in the hopper 
other than wood pellets;

• When the stove is operating, the surfaces, glass, 

handle and tubes become very hot: during 
operation do not touch these parts without 
adequate protection;

• Keep the fuel and other inflammable materials 

off the stove.

Summary of Contents for QUADRA 12D

Page 1: ...USER MANUAL QUADRA 12D...

Page 2: ...epend on usage please read your manual to understand maintenance requirements for your model Please also read our separate sheet regarding the procedures for regular maintenance Ventilation Vents have...

Page 3: ...s of the stove door handle sides can reach high temperatures Therefore pay attention and use the proper precautions above all in the presence of children elderly or disabled persons and animals Assemb...

Page 4: ...contained herein We decline every responsibility derived from improper use of the stove from incorrect use by the user from unauthorized modifications and or repairs from the use of replacement parts...

Page 5: ...he glass door of the pellet stove while the stove is in operation The stove must be connected to an electrical system equipped with an earthing conductor in accordance with regulations 73 23 and 93 98...

Page 6: ...the stove hold down key To replace the 3 volt battery located on the back of the remote control pull the centre of the cover and the lever on the side of the same replace the battery observing the co...

Page 7: ...r to achieve the test report results please load the performance parameters retained by the manufacturer and the qualified technician They will use these parameters once verified that during the insta...

Page 8: ...2 2 448 Heated surface mc 270 Flue gas flow rate min max g s 10 6 Draft min max Pa 10 12 Flue gas temperature min max C 55 2 132 5 Tank capacity Kg 19 Recommended Pellet x H mm 6 x 30 Smoke outlet tub...

Page 9: ...intain a minimum distance of 10 cm at the rear A of 30 cm at the side B and 100 cm at the front If the room contains objects which are believed to be particularly delicate such as drapes sofas and oth...

Page 10: ...pipes and connectors as recommended by us You must ensure that a windproof cowl should be fitted which complies with the standards in force Check with suitable instruments that there is a draught betw...

Page 11: ...duct it must have openings for inspection and cleaning External air intake The stove must be furnished with the air necessary to guarantee the regular functioning of the combustion and an environmenta...

Page 12: ...hich you installed the device check that the floor is not flammable if necessary use a suitable platform in the room where the generator must be installed to heat must not pre exist or be installed wi...

Page 13: ...the vertical or horizontal ducting to the bottom side fastening the flat cable to the board Sliding top cover where present Fan acc 1 It is possible to manually adjust the distribution of air between...

Page 14: ...nd to exit programming is used to switch on and or off the Stove and to exit programming are used to adjust temperature for displays and for the programming functions Buttons and are used to adjust te...

Page 15: ...ume extractor and the cochlea engine are active FIRE PRESENT In this phase of the ignition process the Stove starts loading the pellets into the brazier The fume extractor and the cochlea engine are a...

Page 16: ...IGHTIN The Stove cannot start up This is the first light up Fill in the tank with pellets Start up again ALAR 6 NO PELLET The pellet Stove switched off while working Fill in the tank with pellets ALAR...

Page 17: ...ons 1 and 2 select whether or not to activate the thermostat on off which allows you to program the automatic ignition of the Stove Once the thermostat is activated deactivated press button 4 OFF and...

Page 18: ...9 saturday prog 1 on off 10 sunday prog 1 on off 11 start program 2 hour 12 stop program 2 hour 13 monday progr 2 on off 14 tuesday progr 2 on off 15 wednesday prog 2 on off 16 thursday prog 2 on off...

Page 19: ...es set according to the following table where the OFF setting tells the clock to ignore the command The weekly programmer has 4 independent programmes whose final effect is composed of the combination...

Page 20: ...SDAY PROG 1 on off 02 03 07 THURSDAY PROGR 1 on off 02 03 08 FRIDAY PROGRAM 1 on off 02 03 09 SATURDAY PROGR 1 on off 02 03 10 SUNDAY PROGR 1 on off PROGRAMME 2 menu level selection meaning possible v...

Page 21: ...d the stove switches off Press the key On Off to reset the alarm Wait until the cooling phase is completed Clean the brazier and start a new light up These alarms remind you that the brazier must be c...

Page 22: ...ier Cleaning the scraper where present Cleaning ash collection compartment Cleaning ash tray Cleaning the door and glass Flame shell cleaning where present Cleaning the interior heat exchanger smoke f...

Page 23: ...e of the body stove RESTART PELLET Reduction motor if the motor stops the Stove continues to function until the flame goes out for lack of fuel and until It has cooled down to the minimum level Flue g...

Page 24: ...54 EN...

Page 25: ...brazier and to clean it from any residue foto 4 Raise the stove front to release the T fitting containing compartment foto 3 Turn the ash collection glass foto 4 Remove the combustion chamber floor wi...

Page 26: ...ash deposited within This operation must be performed more or less frequently depending on the quality of the pellets used Cleaning the brazier and brazier support When the flame assumes a red colour...

Page 27: ...n chamber and the ash box Once the preceding points have been observed it only means that the state of the stove has been verified It is necessary to thoroughly clean the smoke discharge tube or flue...

Page 28: ...ed 6 Card defective 1 Check that the power cord is connected 2 Use the switch back to operate it 3 Unplug the stove from the power outlet for about one minute and then turn on If the problem persists...

Page 29: ...e the drawer ashtray 10 Perform periodic cleaning 11 Check the operation of the extractor flue 12 Contact an authorized service center 13 Make sure the place of stowage pellet and replace it with a ha...

Page 30: ...aust fumes Contact your Authorized Service Center 7 Check the quality of the pellets Contact your Au thorized Service Center 8 Increase the level in the parameters relating to the speed of the fan exh...

Page 31: ...oreign objects 7 Close the door or replace the gaskets with original 8 Change the type of pellet recommended by the manufacturer Sometimes depending on the type the stage of adjustment of the paramete...

Page 32: ...e can only take place following the unquestionable decision by the manufacturer in special cases 3 The Company declares no responsibility for any damage that may directly or indirectly result in perso...

Page 33: ...63 EN NOTES Cod 001109...

Page 34: ...64 EN NOTES Cod 001109...

Page 35: ...d should your stove boiler not be commissioned by one of our Authorised Technicians See below for further details Your first point of contact for warranty issues is your Authorised Kalor Dealer where...

Page 36: ...Wood Pellet Stoves ie Newport Co Mayo Ireland Tel 086 012 7744 Email info woodpelletstoves ie Web www woodpelletstoves ie...

Reviews: