background image

 

- 18 - 

 

 

Boiler sold 
by:

 

Company
Sales date: 
Address 
Phone 

Boiler 
installed by: 

Company
Address
Phone 
Foreman 
 

(name, last name, signature) 

 

In case of a 
breakdown 
contact 

 

Company 
Address 
Phone 

 

 
 
 

Manufacturer 

UAB “Šiauli

ų

 tauro kalvis” 

Pramon

ė

s 15,  

LT-78137 Šiauliai, Lithuania 

Phone: (+370 41) 540556 

E-mail: prekyba@kalvis.lt 

 

- 3 - 

KALVIS – 6MPP      2009.05.18 

 

ATTENTION ! 

Get acquainted with this technical certificate before installing the boiler

It 

shall help you to mount and operate the boiler as efficiently as possible

1.

 

Basic engineering data 

Central heating boiler with pellet burner „

Kalvis-6MPP

“ (hereinafter 

referred to as the boiler) is used for heating various premises with installed 
central heating system with enforced water circulation. 

Boiler combusts 6-8 mm diameter saw dust pellets, or may be used as 

a solid fuel (coal, fire-wood) fired boiler, when burner is removed and 
protection is mounted. 

Main technicla data 

Table 1 

Name of parameter 

Parameter value 

Fuel fired 

Saw dust pellets 

(max diameter 

 

6-8 mm) 

Fire wood, waste 

wood, coal, saw 

dust and peat 

briquettes, coal 

Heated area, up to m

2

200 

Fuel load, dm

3

470 50 

Max wood length, mm 

 

380 

Combustion duration*: 

- wood fired, h. 
- coal fired, h. 

130 


Fuel consumptio per heating season, pellets /wood m³  

7 - 8 

20 - 25 

Nominal output, kW 

20 - 25 

Efficiency, no less than: 

- firing wood, % 
- firing coal, % 

80 

72 
78 

Water pressure in the boiler, no greater than, MPa 
(kgf/cm²) 

0,15 (1,5) 

Water volume in the boiler, l 

86 

Water temperature control range, °C 

55 – 90 

70-90 

Minimum recommended water temperature in the boiler 
during operation, °C 

 65 

Recommended water tmeperature during operation, ºC 

70-90 

Minimum chimney draught, Pa 

15 

25 

Smoke outlet dimensions, mm 

Ø198 

Loading dimensions, mm 

270 x 400 

Voltage, V 

230 

Electric capacity (motor + fan), W 

90 + 57  

Electric protection grade 

IP 40 

Loading hole diemnsions: H×B, mm 

 

270 x 400 

Overall dimensions, not greater than:  
height x dempth x lenght, mm 

1390 x 950 x 2260 

Mass, not gretaer than, kg 

365 

*   Combustion duration depends on fuel type and quality, humidity, external conditions 

and other factors. 

 

Firing wood with moisture content of over 30% is not recommended. 

Summary of Contents for 6 MPP

Page 1: ...20 Barcode CENTRAL HEATING BOILER ON SOLID FUEL KALVIS 6 MPP WITH PellX BURNER USER S MANUAL LST EN 303 5 9817 95 ST 144948958 13 2004...

Page 2: ...the fireplace determine the defects and remove them If the aforementioned defects are due to wrong installation and operation of the fireplace I shall cover the arrival costs of your representatives _...

Page 3: ...l fired Saw dust pellets max diameter 6 8 mm Fire wood waste wood coal saw dust and peat briquettes coal Heated area up to m2 200 Fuel load dm3 470 50 Max wood length mm 380 Combustion duration wood f...

Page 4: ...nd ST 144948958 13 2004 12 2 Manufacturer applies the following warranty terms from the date of sale Boiler frame 24 m n Complement 12 m n Consumables para 7 6 m n Manufacturer is obliged to remove al...

Page 5: ...the boiler there is a draught adjuster p 1 that controls air damper p 6 thermomanometer p 2 doors p 4 with servicing doors p 5 behind them and an ash tray p 7 Fuel loading chamber is closed with a co...

Page 6: ...fly out through the chimney It is prohibited to use sawdust for fuel if the distance between chimney and flammable roof or other flammable structures is less than 20 m 4 2 Requirements for chimney Chi...

Page 7: ...be not less than that of the boiler smoke pipe and bending radii not less than 100mm Pipe from the smoke pipe to chimney has to be not longer than 1 5 m and lean upwards toward chimney Joints have to...

Page 8: ...the boiler significantly It is prohibited to fire boiler with fine waste wood due to explosion risk 13 KALVIS 6MPP 2009 05 18 5 1 System preparation for heating Fill system with softened or desalinate...

Page 9: ...12 9 KALVIS 6MPP 2009 05 18...

Page 10: ...10 11 KALVIS 6MPP 2009 05 18...

Reviews: