When boiler is mounted outside the territory of Lithuania, mountign and
installation should proceed according to relevant national regulations.
Error Reason
Solution
Boiler overheats
Too intense combustion.
Power outage (for systems
with enforced circulation)
Close air supply. Monitor boiler
temperature.
When temperature drops return to
regular combusiton mode.
Power outage
Call serviceman.
In case of a risk of system freezing,
during prolonged power outage, drain
water from the boiler
Boiler does not reach
nominal output
Humid fuel.
Insufficient draught.
Use dry fuel.
Check chimney draught, clean the
chimney.
Boiler „weeps“
Bad fuel.
Too low return water
tmeperature
(>57
°
C !).
Use dry fuel.
Adjust mixing valve.
Too high pressure
Boiler overheats. Protection
valve malfunctions.
Close air supply, monitor water
temperature.
Check and replace protection valve.
4.1 Fire precautions:
*
Boiler should be placed on an incombustible material;
*
If boiler is connected to the chimney by metal pipes, pipes should not be
thinner than 1,5mm and they have to be covered by thermal insulation
Attention !
When chimney’s draught is too great and sawdust is used for fuel sparks
may fly out through the chimney.
It is prohibited to use sawdust for fuel, if the distance between chimney
and flammable roof or other flammable structures is less than 20 m.
4.2. Requirements for chimney:
Chimney design and boiler connections into it are shown on the fig 3a,
3b and and 3c.
6.
Safety precautions
3a fig.
Boiler to chimney connection.
* not less than 60
°
A - incorrect B – correct
3b fig.
Chimney insert installation
Prohibited:
•
Disassemble boiler or electric installation;
•
Connect boiler to the system without protection valve, that keeps
pressure in the system below 0,15MPa (1,5 kgf/cm
2
);
•
Close hot or return water valves when boiler is operated;
•
Store dry fuels or other combustible materials close to or on top of the
boiler;
•
Store fuel closer than 500 mm to boiler;
•
Ignition fuel with combustible liquids (petroleum, kerosene etc.);
•
Operate boiler with doors and covers open;
•
Open burner while boiler is operated;
•
Allow children to be by the working boiler without adult supervision;
•
Operate boiler without having it grounded;
•
Rapidly open loading doors during combustion (open a little, wait, then
slowly open wide);
•
Operate boiler with tank cover opened or non hermetic pellet supply
hose;
•
Clean or service boiler when electric power is on.
7.
Consumables
Fire grate and cast iron door may burn up, especially if user combusts
coal, serivicing door and servicing cover fiber gasket may wear out.