- 8 - 

4.3. Connection to heating system 

Recommended connection method is shown in the 4a-4d fig 

 

Boiler may be connected to the heating system according to the project 
prepared by heating equipment specialists or works may be performed 
by a well qualified plumbing welder who is well acquainted with this 
manual and boiler design 

 

Boiler should be connected by hot and return water pipes not smaller 
than 1.5” in diameter  

 

Boiler may be connected to the heating system with the expansion tank, 
where operating pressure does not exceed 0,15 MPa (1,5 kgf/cm2); 

 

If system pipes have valves, that disconnect boiler from the system, 
mounted, they have to be fully opened. To avoid break down due to 
inadvertence, valve handles should be removed. 

 

It is necessary to mount the protection valve that keeps the operating 
pressure in the system not greater than 0,15 MPa (1,5 kgf/cm2). 

 

In order to avoid forming of condesate, which can significantly shorten 
the lifespan of boiler, it is necessary to install a four way mixing valve, 
or thermostatic valve in the system (see recommended connections), 
which will maintain return water temperature above 55

°

C; 

 

It is recommended that boiler is inspected at leats once a year by a 
competent plumbing engineer; 

 

Water draing pipe is used to let the water out of the system whem there 
is a risk of freezing. 
When boiler operates at smaller than nominal output, it‘s efficiency and 

environmental performance drops. It is recommended to use connections 
with accumulation tanks (see. 4c, 4d fig.). Minimum volume of 
accumulation tank is quoted accotrding to the formula provided in 4d fig. 

Mounting of burner and fuel tank with fuel pipe is described in  

PellX 20kW

 user‘s manual. 

5.

 

Operation 

Adults that are well acquainted with the design and users manual may 

operate and service the boiler.  

Attention!

 When firing humid fuel or saw dus, condensate and 

combustion products may form agressive acids that may shorten the 
lifespan of the boiler significantly.  

It is prohibited to fire boiler with fine waste wood, due to explosion risk. 

 

 

 

- 13 - 

KALVIS – 6MPP      2009.05.18 

 

5.1. System preparation for heating  

Fill system with softened or desalinated water and let the air out. Check 

if valves disconnecting boiler from the heating system are fully opened and 
remove their handles. 

5.2. Firing pellets 

Boiler firing with pellets is described in Pellet burner 

PellX 20kW

 user‘s 

manual. 

5.3. Firing boiler with solid fuel 

(1 fig.)

 

Open damper (p.20), load some wood through door (p.5) on the fire 

grate and ignite it. If coal will be fired, take 5 - 10 kg of wood and add a 
layer (about 10 cm) of coal. Secondary air valve  (p.19) has to be closed. 

When fuel is well ignited, loading chamber may be filled with fuel 

(wood, coal). Finer wood increases boiler output. Chminey draught is 
adjusted with damper (p.20). 

Wood should be loaded freely, so that it is able to slide down during 

combustion. 

Coal is added in layers, depending on desired heat output and quality. 
Catalsyt plate should be removed when firing coal. 
Adding fuel: 
-

 

Open door (p.4) and check is ash is not blocking fire grate air gaps. 
Shake the bottom fuel layer, close door in 15...20 seconds; 

-

 

Remove draught adjusters (p.1) chain from the door damper (p.6), so 
that the damper is closed tight; 

-

 

Carefully open fuel cover (p.18), in 5...10 seconds open cover fully 
and add fuel; 

-

 

Close fuel cover; 

-

 

Attach adjuster‘s chain to the damper. 

Secondary air valve (p.19) is opened when temperature in the boiler 

rises to 60

°

C. Valve‘s position is adjusted depending on the fuel type and 

combustion intensity. 

Check the smoek color out of chimney. Smoke should be thin of a light 

grey color. If smoke is thick and black it means incomplete combustion, not 
enough secondary air. Open secondary air valve. 

As a part of combustion process ash is formed, it blocks the openings in 

fire grate, boiler capacity and combuistion intensity drops. Move the fuel 
and ash by pressing the pedal of the fire grate mover. Excess of ash in an 
ashtray blocks primary air supply, that is why ash needs removal. 

Unless there is a necessity it is not recommended to open fuel loading 

doors during combustion.

Summary of Contents for 6 MPP

Page 1: ...20 Barcode CENTRAL HEATING BOILER ON SOLID FUEL KALVIS 6 MPP WITH PellX BURNER USER S MANUAL LST EN 303 5 9817 95 ST 144948958 13 2004...

Page 2: ...the fireplace determine the defects and remove them If the aforementioned defects are due to wrong installation and operation of the fireplace I shall cover the arrival costs of your representatives _...

Page 3: ...l fired Saw dust pellets max diameter 6 8 mm Fire wood waste wood coal saw dust and peat briquettes coal Heated area up to m2 200 Fuel load dm3 470 50 Max wood length mm 380 Combustion duration wood f...

Page 4: ...nd ST 144948958 13 2004 12 2 Manufacturer applies the following warranty terms from the date of sale Boiler frame 24 m n Complement 12 m n Consumables para 7 6 m n Manufacturer is obliged to remove al...

Page 5: ...the boiler there is a draught adjuster p 1 that controls air damper p 6 thermomanometer p 2 doors p 4 with servicing doors p 5 behind them and an ash tray p 7 Fuel loading chamber is closed with a co...

Page 6: ...fly out through the chimney It is prohibited to use sawdust for fuel if the distance between chimney and flammable roof or other flammable structures is less than 20 m 4 2 Requirements for chimney Chi...

Page 7: ...be not less than that of the boiler smoke pipe and bending radii not less than 100mm Pipe from the smoke pipe to chimney has to be not longer than 1 5 m and lean upwards toward chimney Joints have to...

Page 8: ...the boiler significantly It is prohibited to fire boiler with fine waste wood due to explosion risk 13 KALVIS 6MPP 2009 05 18 5 1 System preparation for heating Fill system with softened or desalinate...

Page 9: ...12 9 KALVIS 6MPP 2009 05 18...

Page 10: ...10 11 KALVIS 6MPP 2009 05 18...

Reviews: