Thank you for purchasing this KAM product, we are sure that it will serve you for many years to come. 

 
To optimise the performance of this product, please read these operating instructions carefully to familiarise yourself 
with the basic operations of this unit. After you have read the instructions, please retain them for future reference. 
 
This unit has been tested at the factory before being shipped to you.  
 
To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or moisture. To prevent a fire 
hazard, do not expose the unit to any naked flame sources. Unplug this apparatus during lightning storms or if it is 
unlikely to be used for long periods of time. 
 
When installing the unit, please ensure you leave enough space around the unit for ventilation. Slots and openings in 
the unit are provided for ventilation to ensure reliable operation of the product and to protect it from overheating. To 
prevent fire hazard, the openings should never be blocked or covered. 
 
Always handle the power cable by the plug. Never pull out the plug by pulling on the cable. Never touch the power 
cable when your hands are wet as this could cause an electric shock. Do not tie a knot in the cable. The power cable 
should be placed such that it is not likely to be stepped on. A damaged power cable can cause a fire or give you an 
electrical shock. Check 
the power cord periodicaly, if you ever find that it is damaged, replace it before using the unit again. Contact your 
retailer for a replacement. 
 
The voltage of the available power supply differs according to country or region. Be sure that the power supply 
voltage of the area where this unit is to be used meets the required written on the unit. 

 

The lightning flash symbol inside a triangle is intended to alert the user to the presence high voltage within 
the unit’s enclosure that may be of sufficient power to constitute a risk of electrical shock to persons.

 

 
Caution: to prevent the risk of electric shock, do not attempt to open the unit. No user-serviceable parts 
inside. Refer all servicing to qualified service personnel. 
 
The exclamation mark inside a triangle is intended to alert the user to the presence of important operating 
and maintenance instructions in the literature accompanying the appliance. 

 
Any modification carried out on the unit may invalidate the unit’s warranty. 
 
If applicable, only use the stand, tripod or bracket specified or sold with the apparatus. 
 
Select the installation location of your unit carefully. Avoid placing it in direct sunlight or locations subject to vibration 
and excessive dust. Do not use the unit where there are extremes in temperature (below 41ºF / 5ºC or exceeding 
95ºF / 35ºC). 
 
Unpacking and safety: Please unpack your new product carefully, your new product should reach you in perfect 
condition. Please check that no damage has occurred during transit. If any damage is found, do not operate your unit. 
Please contact the retailer you purchased it from immediately. If there is any damage to the mains cable do not use 
the device. Always disconnect the unit from the mains supply when carrying out any servicing or cleaning of the unit.  
 
The serial number for this equipment should be located on the rear or underside of the unit. Please make a note of 
this number as you will need it for your warranty, it is a good idea to keep a copy of the serial number for your own 
records. 

 
 
 

 

Summary of Contents for iLINK GREEN

Page 1: ...N U A L V E R S I O N 1 0 2 8 0 6 1 2 For the latest instruction manual updates and information on the entire Kam range visit www kam co uk Kam products are manufactured by Lamba plc Unit 1 Southfiel...

Page 2: ...e sure that the power supply voltage of the area where this unit is to be used meets the required written on the unit The lightning flash symbol inside a triangle is intended to alert the user to the...

Page 3: ...LE FIXTURE IS OPERATING 4 Power Switch Switch ON and OFF the fixture 5 Fuse Holder Replace fuse with correct value if required 6 Main Power Input IEC socket and integrated fuse holder 7 Interlock For...

Page 4: ...unit and contact your dealer immediately Note There will output from laser 5 seconds after the unit is powered on Operation Standalone pre program laser show Press FUNC to enter MODE OPTION Till the L...

Page 5: ...ory DMX mode Press FUNC to enter MODE OPTION Till to LED panel shows 001 Use the up down buttons to select the desired DMX starting address Press ENTER to confirm the setting The laser is working in D...

Page 6: ...on for 2 seconds will activate the REM mode Auto Auto running slow Music Sound Activated show The blue music LED indicator is flashing when sound signal is detected Sound sensitivity In Sound Activate...

Page 7: ...ton until SLA is displayed then press the enter button to confirm Only one unit must be set as a master and all other units as a slave Connect each unit together via a 3pin DMX lead DMX Protocol CHANN...

Page 8: ...1 168 175 232 239 048 055 112 119 176 183 240 247 056 063 120 127 184 191 248 255 Specifications Mains Input AC100 240V 50 60Hz Fuse 250V 1 A slow blow 20mm Glass Total Power 12W Music Control Interna...

Reviews: