DMX control mode 
 

DMX channel  DMX value  Function 

Channel 1 

000 - 005 

0% output 

006 - 255 

5% - 100% output 

 
 

 

 
To set the DMX address please see the table below and set using the dip switches on the rear of the unit

 (see diagram).

 

Note: 1 = On, 0 = Off 
 

DMX address 

DIP Switches 

 

16 

32 

64 

128 

256 

... 

... 

... 

... 

... 

... 

... 

... 

... 

... 

410 

 
Fuse Replacement: 

Unplug the IEC power cable before replacing the fuse! Always replace with same type of fuse. 
1. Using a flat head screwdriver, remove the fuse holder from the IEC housing.  
2. Remove the bad fuse from the fuse holder. 
3. Insert the new fuse into the fuse holder. 
4. Install the fuse holder in the IEC housing. 

 

Mounting : 
Orientation: 

This fixture should only be mounted/used on a flat surface. This fixture should not be tilted. 

Rigging: 

It is important never to obstruct the vents’ pathways. Mount the fixture using, a suitable “C” or “O” type clamp. 

When selecting installation location, take into consideration the fluid reservoir access and routine maintenance. 
Safety cables must always be used, utilising the provided safety eye bolt. 

Never mount in places where the fixture will be exposed to rain, high humidity, extreme temperature changes or restricted ventilation. 

 
General maintenance 

To maintain optimum performance and minimise wear, the item should be cleaned frequently. Usage and environment are 
contributing factors in determining the cleaning frequency. As a general rule, fixtures should be cleaned after use to avoid dust build-

up and blockages, which can result in poor performance, overheating and breakages. Be sure to uplug the unit from the mains 

before

 conducting any maintenance. Use a vacuum and a soft brush to remove dust collected on external vents and internal 

components. Clean the external case when the unit has 

completely

 cooled down with a dry cloth or tissue.  

 

Regular maintenance 

Be sure to power off fixture 

before

 conducting any maintenance. Every 40 hours of continuous operation, it is recommended to run a 

cleaning solution

 composed of 80% 

distilled

 water and 20% distilled 

white vinegar

 through the system to prevent the 

accumulation of particulate matter in the heating element. 
The recommended cleaning regime is as follows: 
1. Empty all haze/smoke fluid from the machine.  
2. Add the above 

cleaning solution

 to the tank (80% 

distilled

 water and 20% distilled 

white vinegar

).  

3. Plug the unit in to the mains and allow it to warm up.  
4. Run the unit in a well-ventilated area until the tank is almost empty. 

Do not allow the pump to run dry.

  

Cleaning is now complete. Refill with haze/smoke fluid. Run the unit briefly to clear any cleaning solution from the system. 