background image

Troubleshooting 

  

Problem 

Check list 

Troubleshooting 

No output - 
the unit does not 
appear to work 

1. Check if the power cord is connected to the input 
mains socket of the unit. 
2. Check if the ambient temperature in a safe range. 

1. Make sure there is mains present to the cable, 
check the fuse or replace the cable. 
2. Ensure the ambient temperature is suitable. 

LEDs are dimmed 

1. Check if the power cord is connected to the input 
mains socket of the unit. 

1. Make sure the mains input voltage is the  
correct voltage. 

No DMX input 

1. Check that the cable is not damaged. 
2. Check the polarity of the pin connections is correct. 
3. Check lf the unit is in DMX mode. 
4. Check if 2 units are set as Master units in a chain. 

1. Change the DMX cable. 
2. Correct the DMX polarity or change the cable. 
3. Set up the function mode as DMX. 
4. Set all other units as Slave units in the chain. 

 

 
Technical specifications 

DMX512 control channels: 

8 / 15 / 20

 

DMX512 input & output connection:

 3 pin XLR 

Mode: 

DMX512 / Auto / Sound-to-Light / Master/Slave 

LEDs: 

5 x 30w COB LED 

Power supply: 

IEC mains / AC 120-230V 50/60Hz 

Dimensions (WxDxH): 

575 x 145 x 120mm

 (not including brackets) 

Weight: 

4Kg

 

 