![background image](http://html1.mh-extra.com/html/kam/powerstrip5/powerstrip5_manual_3337074005.webp)
Troubleshooting
Problem
Check list
Troubleshooting
No output -
the unit does not
appear to work
1. Check if the power cord is connected to the input
mains socket of the unit.
2. Check if the ambient temperature in a safe range.
1. Make sure there is mains present to the cable,
check the fuse or replace the cable.
2. Ensure the ambient temperature is suitable.
LEDs are dimmed
1. Check if the power cord is connected to the input
mains socket of the unit.
1. Make sure the mains input voltage is the
correct voltage.
No DMX input
1. Check that the cable is not damaged.
2. Check the polarity of the pin connections is correct.
3. Check lf the unit is in DMX mode.
4. Check if 2 units are set as Master units in a chain.
1. Change the DMX cable.
2. Correct the DMX polarity or change the cable.
3. Set up the function mode as DMX.
4. Set all other units as Slave units in the chain.
Technical specifications
DMX512 control channels:
8 / 15 / 20
DMX512 input & output connection:
3 pin XLR
Mode:
DMX512 / Auto / Sound-to-Light / Master/Slave
LEDs:
5 x 30w COB LED
Power supply:
IEC mains / AC 120-230V 50/60Hz
Dimensions (WxDxH):
575 x 145 x 120mm
(not including brackets)
Weight:
4Kg
Due to continuous product development, specifications and appearance are subject to change. © Copyright Lamba plc. E&OE.