Lüftungskomponenten, Kombinationsschlitzdurchlass

Assembly, installation and operating instructions

5

2

Safety

This section provides an overview of all important safety aspects to ensure optimum protection of personnel as well as safe
and trouble-free operation. In addition to the safety instructions in these operating instructions, the valid safety, accident pre-
vention and environmental protection regulations must be observed for the area of use of the unit. It is the duty of the oper-
ator to ensure that instructions relating to maintenance (e.g. relating to hygiene) are complied with.

2.1

Correct use

Intended use of the unit also includes adherence to these instructions.

Information in accordance with EN60335-1

This unit can be used by children aged 8 years or more and also by people with reduced physical, sensory or mental cap-
abilities or a lack of experience and knowledge, if they are supervised or have been instructed in the safe use of the unit
and the resulting dangers. Do not allow children to play with the unit. Do not allow children to clean and maintain the
unit without supervision.
This unit is not intended for permanent connection to the drinking water supply system.
This unit is intended for being accessible to the general public.

Any use beyond or other than the stated intended use is considered as misuse.

Any change to the unit or use of non-original spare parts will cause the expiry of the warranty and the manufacturer’s liabil-
ity.

2.2

Limits of operation and use

Variable

Value

Unit

Temperature range

0 – 50

°C

Max. relative air humidity

90

%

IMPORTANT NOTE!

Warning of misuse!

In the event of misuse, as itemised below, there is a danger of limited or failing operation of the unit. En-
sure that the airflow can circulate freely.

Never operate the unit in humid areas, such as swimming pools, wet areas etc.
Never operate the unit in rooms with an explosive atmosphere.
Never operate the unit in aggressive or corrosive atmospheres (e.g. sea air).

Summary of Contents for KS

Page 1: ...KS Assembly installation and operating instructions Keep these instructions in a safe place for future use Issue02 22EN SAP No 1562744...

Page 2: ......

Page 3: ...torage 8 3 4 Packaging 8 4 Construction and function 9 4 1 Overview 9 4 2 Brief description 9 4 3 Dimensions Nominal lengths 10 5 Installation and wiring 11 5 1 Requirements governing the installation...

Page 4: ...instructions contained in this manual In addition all local occupational health and safety at work regulations apply as do general safety provisions governing the use of the equipment Illustrations in...

Page 5: ...dge if they are supervised or have been instructed in the safe use of the unit and the resulting dangers Do not allow children to play with the unit Do not allow children to clean and maintain the uni...

Page 6: ...y and accident prevention regulations Guidelines and recognised technical regulations i e Association of German Electricians VDE regulations DIN and EN standards VDI 6022 maintenance personnel must be...

Page 7: ...on the Kampmann website IMPORTANT NOTE 2 people are needed to transport the unit Wear personal protective clothing when transporting the unit Only lift the unit on both sides and not by the pipes valv...

Page 8: ...e place Do not expose to aggressive media Protect from direct sunlight Avoid mechanical vibrations and shocks IMPORTANT NOTE Under certain circumstances packages can carry storage instructions that ex...

Page 9: ...class B1 5 Partition between supply air and extract air 6 Eccentric rollers in supply air 7 Nozzle rollers in extract air 4 2 Brief description The KS is a combined diffuser for use in and behind dry...

Page 10: ...B A Fig 2 Views of KS All figures in mm Dimensions Nominal length 550 mm Nominal length 750 mm Nominal length 950 mm Nominal length 1150 mm A air outlet front 550 750 950 1150 B width of junction box...

Page 11: ...the unit Technical data Make sure that the ceiling is sufficiently load bearing to take the weight of the unit Technical data Make sure that the unit is securely suspended standing Ensure that the air...

Page 12: ...dry wall element before installing the KS A B Fig 4 Dimensions of the installation opening mm Dimensions Nominal length 550 mm Nominal length 750 mm Nominal length 950 mm Nominal length 1150 mm A 521...

Page 13: ...13 Fig 6 Note the installation areas Do not screw the installation brackets into the areas marked with a Fig 7 Installing the air outlet front When installing the KS pay attention to the correct insta...

Page 14: ...s shown on the diagram below using a slot head screw driver C D 4 3 B C A B 1 A 3 2 2 1 D E E F F 6 6 5 5 4 A B C D E F 6 1 2 3 4 5 min max Reading area Volumetric flow Air stream directions Fig 8 Con...

Page 15: ...tions have been met so that the unit can function safely and properly Structural tests Check that the unit is securely standing and fixed Check the horizontal installation suspension of the unit Check...

Page 16: ...unit outlet elements etc for dirt or deposits dur ing maintenance and use a commercially available product to remove Fig 10 Dismantling the air outlet front Dismantle the air outlet front for cleanin...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...produkte luftdurchlaesse ks Country Contact Great Britain Kampmann UK Ltd Dial House Govett Avenue Shepperton Middlesex TW17 8AG T 44 1932 228592 F 44 1932 228949 E info kampmann co uk W Kampmann co u...

Reviews: