11

2 .4  Diagram of signal conversion

Signal 

indicated 

in dBm

Signal 

with 

button 

test

Signal 

indicator

• 

Note: At a signal strength 
below 12, a stable 
connection to the unit 
cannot be guaranteed.

• 

The installation must not 
be handed over before 
the signal strength is 12 
or more. In some cases 
it might be necessary to 
mount an external antenna.

• 

If an external antenna is 
mounted, this must be 
positioned in a place where 
it is not shielded, covered, 
or moved. Nor must it be 
mounted in closed metal 
cabinets.

•  Only use dual-band GSM 

antennas.

• 

Always complete the 
installation by sending an 
SMS (

=signal#

) to control 

the signal strength when 
all doors and cabinets are 
closed.

-113

0

0

-111

1

0

-109

2

0

-107

3

0

-105

4

0

-103

5

0

-101

6

0

-99

7

0

-97

8

0

-95

9

1

-93

10

1

-91

11

1

-89

12

2

GSM minimum

-87

13

2

-85

14

2

-83

15

3

-81

16

3

-79

17

3

-77

18

4

-75

19

4

-73

20

4

-71

21

5

-69

22

5

-67

23

5

-65

24

5

-63

25

5

-61

26

5

-59

27

5

-57

28

5

-55

29

5

-53

30

5

-51

31

5

Summary of Contents for GSM7i

Page 1: ...Installation and user manual GSM7i Kamstrup A S Industrivej 28 Stilling DK 8660 Skanderborg TEL 45 89 93 10 00 FAX 45 89 93 10 01 info kamstrup com www kamstrup com...

Page 2: ...that all cabinets and doors are closed before sending the SMS Tips Always install an external antenna when installing the unit in a metal cabi net The antenna must be placed outside the cabinet Use du...

Page 3: ...rd requirements 14 2 7 Mounting of external antenna to be ordered separately 14 2 7 1 Activating the external antenna 15 2 7 2 Positioning of external antenna 16 2 8 Mounting status pulse input 17 2 9...

Page 4: ...he module Application With the module GSM7i the metering point is future proofed since the module supports GSM GPRS and SMS In addition it is possible to mount an extra Add on module On this Add on mo...

Page 5: ...mode Kamstrup 162J Kamstrup 282J Kamstrup 382J 6816 Dxxxx Communication with GSM7i data logger Data logger mode Kamstrup 162J Kamstrup 282J Kamstrup 382J Does not apply to 162 282BCDE and 382BCDE met...

Page 6: ...ral upload of new features e g new tariff switch times Built in real time clock RTC with minimum backup for 10 days RTC controlled GPRS reset Reading of electricity meters via SMS Status LED s for GSM...

Page 7: ...7...

Page 8: ...nsert SIM card see paragraph 2 6 1 page 13 4 When the diodes on the GSM7i module stop flashing the signal strength is read on the indicator see paragraph 2 4 page 11 5 If the signal strength is accept...

Page 9: ...e module has been connected to the network after approx 5 10 secs 3 Now the signal indicator will show the current signal level 4 If the module is configured for communication via GPRS the GPRS diode...

Page 10: ...a higher resolution of the signal strength is required it is possible to make a signal test with the test button 1 Press the button for 2 secs after which the test diode turns on and lights for approx...

Page 11: ...s mounted this must be positioned in a place where it is not shielded covered or moved Nor must it be mounted in closed metal cabinets Only use dual band GSM antennas Always complete the installation...

Page 12: ...GPRS connection Test Orange Is used for alternative signal test LED emits light constantly Emits light constantly for approx 10 secs during signal test LED flashes constantly The module cannot commun...

Page 13: ...ened the connection to the SIM card is disrupted When the SIM card has been inserted correctly and the holder is closed the module will restart automatically If the unit is supplied without a SIM card...

Page 14: ...n be used 2 7 Mounting of external antenna to be ordered separately Connect the external antenna to the connector on the module Be careful to hear a click before the two connectors are connected corre...

Page 15: ...Directional antenna order no 6699456 When using other antennas the external antenna is selected manually in the following way By default the internal antenna has been selected EXT ANT light emitting...

Page 16: ...nting the antenna outdoors we recommend using Kamstrup s antennas since they are vandal proof Select a position where the antenna is not shielded by an open door or the like Place the antenna near win...

Page 17: ...e contact or as pulse input from e g a water meter If it is used as pulse input the pulses will be counted in the pulse register of the electricity meter Note that the electricity meter must be config...

Page 18: ...tion between electricity meter and recommended relay type G2RS OMRON is shown below 2 10 Mounting of add on module The module is prepared for connection of an add on module in order to make it possibl...

Page 19: ...19...

Page 20: ...he module to continue data logging once the power is re established Logged data are stored in the EEPROM of the module and therefore they are not lost in connection with power failure NOTE As a precau...

Page 21: ...4 Kamstrup 162J Primary energy kWh 0 Tariff 1 kWh Tariff 2 kWh Kamstrup 382J Primary energy kWh 0 Tariff 1 kWh Tariff 2 kWh Control Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Phase 1 Phase 2 Phas...

Page 22: ...or e g determining the duration of a voltage cut off two minutes being the minimum duration to register The logging depth is 64 events The register structure of the event logger Time stamp Control Yea...

Page 23: ...rmore low tariff can be active on 30 optional days Shift into T1 Shift into T2 Monday Friday 1 shift day 1 shift day Saturday Sunday 1 shift day 1 shift day It is possible to have two shiftings within...

Page 24: ...lier Replace the SIM card or contact your telecom supplier in order to activate it LED 3 flashes SIM card is defect Replace SIM card The GPRS diode does not emit light after start up Check the order t...

Page 25: ...a page 16 Mount a directional GSM antenna Please contact Kamstrup A S for further details Insert a SIM card from another telecom supplier since there might be difference in GSM coverage between the su...

Page 26: ...kWh 343 W 2452 Hours Meter No 10101010 Return reply error NO ANSWER SIGNAL for reading the signal strength Syntax command SIGNAL Example SIGNAL Return reply correct Displays the current signal strengt...

Page 27: ...PUT out1 out2 Example Switch on relay 1 immediately CONTROL_OUTPUT 1 0 Example Switch off relay 1 immediately CONTROL_OUTPUT 0 0 Return reply error NO ANSWER Read APN for controlling the APN name in c...

Page 28: ..._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 Kit Kamstrup 162 module and top cover _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 Kit Kamstrup 382 module and top cover _ _ _ _ _...

Reviews: